Dimplex CFP4949BW Service Manual Download Page 4

 

 

 

 

 

 

 

 

 

 

 

 

www.dimplex.com

MAINTENANCE

WARNINg: 

 Disconnect power before attempting 

any maintenance or cleaning to reduce the risk of fire, 

electric shock or damage to persons.

  CAUTION:  

Allow at least five (5) minutes for the light 

bulbs to cool before touching them to avoid accidental 

burning of the skin.  
The light bulbs need to be replaced when you notice a dark 

section of the flame or when the clarity and detail of the log 

ember bed exterior reduces.  There are two (2) bulbs under 

the ember bed, which generate the flames and embers.

Light Bulb Requirements

Quantity of two (2) clear chandelier or candelabra bulbs 

with an E-12 (small) socket base, 60 Watt rating.  Example: 

GE 60BC or Philips 60 CTC.

Do not exceed 60 Watts per bulb

Bulb Replacement

The bulbs are located under the Ember Bed.  

To gain access to the bulbs:

Remove the nut and washer as indicated in Figure 3 

1. 

and pull the front trim away from the fireplace (Figure 

4).
Remove three (3) screws holding Ember Bed in place 

2. 

(Figure 4).
Release left side of Flicker Rod by turning rod and 

3. 

plastic bushing to match key slot of bracket.  Pull 

forward to clear bracket.
Remove the defective lamp(s) by unscrewing counter 

4. 

clockwise.

Replace with a 60 Watt E12  clear chandelier or 

5. 

candelabra.  Take care not to over-tighten the bulb.
Refit the Flicker Rod and Ember Bed, and secure with 

6. 

the screws removed in step 2.
Refit front trim and secure with washer and nut.

7. 

!

NOTE:

  To remove the firebox insert prior to repair, 

remove the nine (9) black screws at the back of the 

firebox as shown in Figure 3 and slide it out to the back.

 

Helpful Hints

It is a good idea to replace all light bulbs at one time if they 

are close to the end of their rated life.  Group replacement 

will reduce the number of times you need to open the unit 

to replace light bulbs.

Cleaning 

 WARNINg

:  Always disconnect from the power supply 

before cleaning the fireplace.

For general cleaning use a soft clean duster – never use 

abrasive cleaners.  The glass viewing screen should be 

cleaned carefully with a soft cloth.  DO NOT use glass 

cleaners. 
To remove any accumulation of dust or fluff, the soft brush 

attachment of a vacuum cleaner should occasionally be 

used to clean the outlet grill of the fan heater.

Figure 3

Figure 4

Washer 

& Nut

Screws to 

remove: 3 per 

side and 3 

along top edge

Screws

Flicker Rod

Front Trim

Ember Bed

Summary of Contents for CFP4949BW

Page 1: ...implex North America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 00 20 JAN 12 IMPORTANT SAFETY INFORMATION Always...

Page 2: ...l result in damage to the equipment Warning Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death OPERATION 3 MAINTENANCE 4 EXPLODE...

Page 3: ...ler for recycling advice in your area OPERATION MANUAL CONTROLS A 3 Position Switch The switch has two On positions marked with I and II The I position is for manual operation In this position the bui...

Page 4: ...ot of bracket Pull forward to clear bracket Remove the defective lamp s by unscrewing counter 4 clockwise Replace with a 60 Watt E12 clear chandelier or 5 candelabra Take care not to over tighten the...

Page 5: ...P REMOTE CONTROL RECEIVER 5 3000380200RP REMOTE CONTROL 6 3000370500RP 3 POSITION SWITCH 7 2800071100RP HEATER SWITCH 8 2800070900RP HEATER ASSEMBLY 9 2200491200RP MINI BROCKTON TRIM 10 6905840184RP C...

Page 6: ...6 www dimplex com WIRING DIAGRAM...

Page 7: ...otor 10 that secure the retaining bracket to the back panel the one that both the flicker motor and the light sockets are attached to Also remove the 2 screws directly above the rear left foot as well...

Page 8: ...g If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin Warning Disconnect power before attem...

Page 9: ...cord out of the casing Connect the new power cord into the same location 12 Reassemble in the reverse order as above 13 REMOTE CONTROL RECEIVER REPLACEMENT Tools Required Phillips head Screwdriver Sli...

Page 10: ...er cord Replace power cord if cord gets hot to the touch Appearance Fireplace does not turn on Manu ally Improper operation Refer to Operation Section No incoming voltage from the electrical wall sock...

Page 11: ...the heater emits an odor for a brief period after the heater is initially turned on The heater is burning off any dust accumulated during manufacturing or operation Defective Heater Assembly Replace H...

Reviews: