8
www.dimplex.com
Fireplace Installation
Wiring
WARNING:
To reduce the risk
of fire, electric shock or injury to
persons, always use a licensed
electrician.
WARNING:
Ensure that the circuit
on which the fireplace is to be
installed has the power cut off at
the service panel until installation
is complete.
1. Carefully remove the electrical
cover bracket from the back of the
fireplace by removing the three
retaining screws. (Figure 2)
2. Leaving a minimum of 3 in. (7.6
cm) of slack, route the power
supply through a cable clamp
(not included) and the hole in the
electrical cover bracket.
3. Remove the two covers off of the
unit at the front to access the wire
connections. (Figure 3)
Wiring Diagram
AC/DC
ADAPTER
RELAY BOARD
SWITCH BOARD
DISPLAY / CONTROL BOARD
THERMISTOR
LED STRIPS
(RGB) - MEDIA
FLAME LED STRIPS (AMBER)
CUTOUT
THERMAL
FLICKER MOTOR
BLOWER MOTOR
LED STRIPS
(RGB) - FLAME
M
M
ELEMENTS
LED DRIVER
BOARDS
Figure 2
Screws
Electrical Cover Bracket