The Clean Air Act 1993 and Smoke Control Areas

Under the Clean Air Act local authorities may declare the whole 

or part of the district of the authority to be a smoke control area. It 

is an offence to emit smoke from a chimney of a building, from a 

furnace or from any fixed boiler if located in a designated smoke 

control area. It is also an offence to acquire an “unauthorised fuel” 

for use within a smoke control area unless it is used in an “exempt” 

appliance (“exempted” from the controls which generally apply in 

the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs 

has powers under the Act to authorise smokeless fuels or exempt 

appliances for use in smoke control areas in England. In Scotland 

and Wales this power rests with Ministers in the devolved 

administrations for those countries. Separate legislation, the Clean 

Air  (Northern  Ireland)  Order  1981,  applies  in  Northern  Ireland. 

Therefore it is a requirement that fuels burnt or obtained for use 

in  smoke  control  areas  have  been  “authorised”  in  Regulations 

and that appliances used to burn solid fuel in those areas (other 

than “authorised” fuels) have been exempted by an Order made 

and signed by the Secretary of State or Minister in the devolved 

administrations.
The Bellingham 5kW stove has been recommended as suitable for 

use in smoke control areas when burning wood and manufactured 

smoke less fuels. The air control has been set to ensure a minimum 

burn rate for clean burning during operation.
Further information on the requirements of the Clean Air Act can 

be found here : http://smokecontrol.defra.gov.uk/ 
Your  local  authority  is  responsible  for  implementing  the  Clean 

Air Act 1993 including designation and supervision of smoke 

control areas and you can contact them for details of Clean Air 

Act requirements

After Sales Service

As  a  sign  of  our  commitment  to  quality,  all  new  Dimplex  solid 

fuel stoves are guaranteed against casting faults and other 

manufacturing  defects  for  10  years  in  the  case  of  non-boiler 

stoves and 5 years in the case of boiler models, subject to certain 

conditions and exclusions. The guarantee covers the main body 

of the stove and external cast parts under normal domestic use 

- it does not cover use in commercial premises. The guarantee 

period  begins  on  the  date  of  purchase. The  guarantee  covers 

replacement of the parts found to be defective but does not cover 

labour charges. 

Conditions and Exclusions:

The guarantee does not cover the following items which are 

deemed to be consumable items under normal use: glass, rope 

seals, grate, ashpan, cast iron liners, riddling lever, baffle plate, 

fire bricks and log retainer.

It is a condition of the guarantee that the installation complies 

with relevant Building Regulations and is carried out by a suitably 

qualified individual (HETAS registered in England and Wales, or 

equivalent in other countries) with certificate of installation and 

appropriate commissioning retained by the end-user along with 

proof of purchase. 

Whilst the guarantee does not cover any aspect of the flue 

arrangements for the installation, or the installation work itself, as 

these are beyond the control of Dimplex as the manufacturer of 

the stove, it is a condition of the guarantee that the flue be swept 

by a suitably qualified individual as appropriate but at a minimum 

interval of once per year. It is expected that the stove would be 

inspected for developing faults at the time of sweeping to allow 

any necessary maintenance to be carried out.

- 9 -

Damage or defects caused by the following are excluded: over-

firing,  use  of  inappropriate  fuels  such  as  petroleum  coke  or 

household rubbish, flue draft problems, ventilation issues, accident, 

misuse, fair wear and tear, unauthorised modifications or repairs 

made using incorrect spares.
In normal usage the paint finish of the stove may change colour 

slightly or lighten in shade over time. This is considered normal and 

is not covered by the guarantee. Damage caused by over-firing is 

excluded from the guarantee.  

It is a condition of the guarantee that only genuine Dimplex spare 

parts are used. Parts that may need occasional replacement are 

fire bricks, ashpan, grate and log retainer. NB: sealing rope and 

rope adhesive are generic stove spares that can be purchased 

from most stove retailers. Provided the rope seals are replaced 

like for like and fixed with appropriate stove rope adhesive, this 

will not invalidate the guarantee. 
Genuine Dimplex spare parts are available in the UK direct from 

the manufacturer and can be ordered via www.dimplex.co.uk or 

by telephone on 0845 600 5111. For Republic of Ireland orders 

see www.dimpco.ie or Tel: 01 842 8222

Dimplex reserves the right to provide either replacement parts or 

a replacement stove, at their sole discretion, in order to satisfy 

claims made under this guarantee.

Replacement parts or stoves are covered only for the remainder 

of the original guarantee period.
Dimplex  will  not  be  held  responsible  for  any  consequential  or 

incidental loss, damage or injury, howsoever caused.
The Dimplex stove guarantee does not affect, and is in addition 

to, your statutory rights.    
Should  you  require  after  sales  service  or  should  you  need  to 

purchase any spares, please contact the retailer from whom the 

appliance was purchased. Please do not return a faulty product 

to us in the first instance as this may result in loss or damage and 

delay in providing you with a satisfactory service. Please retain 

your receipt as proof of purchase.

Summary of Contents for Bellingham 12kW BLM12SE

Page 1: ...te Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls Installation should only be carried out by a suitably qualified installer Di...

Page 2: ...n Bellingham 5kw Nominal heat output Wood kW 5 0 Solid Fuel Ancit kW 4 9 Efficiency Wood 84 8 Solid Fuel Ancit 85 0 CO Emission 13 O2 Wood 0 34 Solid Fuel Ancit 0 33 Flue Gas Temp Wood C 210 Solid Fue...

Page 3: ...ppliance 300mm or 1200mm from hearth whichever is greater 0mm 51 150mm 75mm 0 150mm 150 300mm 75mm 150mm 300mm No Minimum Requirement H MIN 150mm X X T T MIN 150mm MIN 125mm See Table 3 Solid non comb...

Page 4: ...11 9 10 8 CLOSURE PLATE SEAL 150mm max Fire proof seal or fire cement 150mm max C B A 4...

Page 5: ...suitable protective gloves when handling In case of contact wash immediately with plenty of water Asbestos This appliance contains no asbestos If there is a possibility of disturbing asbestos as a res...

Page 6: ...ame room as this appliance 6 Floor Protection Installation Clearances In all instances the stove must be positioned on a non combustible hearth that conforms to Building Regulations and is firm secure...

Page 7: ...rformance the stove should not be overfilled with fuel above the height of the rear brick ideally the top 1 height of the rear brick should be visible at all times Overfilling can cause poor operation...

Page 8: ...th a proprietary glass cleaner or some damp newspaper Do not use abrasive materials as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed po...

Page 9: ...ainer It is a condition of the guarantee that the installation complies with relevant Building Regulations and is carried out by a suitably qualified individual HETAS registered in England and Wales o...

Page 10: ...10...

Page 11: ...R HANDLE ASSEMBLY 4 19089 0 16 GRATE FRAME 1 70421 0 5 DOOR CATCH 1 70181 0 17 RIDDLE ARM 1 70422 0 6 DOOR GLASS 1 70100 0 18 AIR CONTROL HANDLE 1 71035 0 7 GLASS FIXING BKT 1 70101 0 19 LEG 1 70096 0...

Page 12: ...n SO30 2DF t 44 0 844 879 3588 f 44 0 1489 773050 e aftersales dimplex co uk w www dimplex co uk Northern Ireland Glen Dimplex Northern Ireland 5 Charlestown Avenue Charlestown Industrial Estate Craig...