Dimplex Bellingham 12kW BLM12SE Operating Instructions Manual Download Page 2

Max

+

_

+

Solid Fuel

Burning

Wood

Burning

Max

Boost/
Refuel

Min

1

Table 1 - Dimensions

A

B

C

D

E

F

G

H

I

J

K

Bellingham 5kw

596

466

35

233

120

368

70

140

195

465

127

Note: All Dimensions in mm. Dimensions stated may be subject to a slight ± variation. ( 25.4mm = 1”)

Table 2 - Technical Specification

Bellingham 5kw

Nominal heat output

Wood

kW

5.0

Solid Fuel (Ancit)

kW

4.9

Efficiency

Wood

%

84.8

Solid Fuel (Ancit)

%

85.0

CO Emission (@13% O

2

)

Wood

%

0.34

Solid Fuel (Ancit)

%

0.33

Flue Gas Temp

Wood

°C

210

Solid Fuel (Ancit)

°C

215

Flue Gas Mass Flow

Wood

g/s

3.3

Solid Fuel (Ancit)

g/s

2.9

Refuel Period

hr

1

Safe Distance to Combustibles 

mm

see table 5

Flue Outlet Size

mm / inch

127 / 5

Product Weight

kg

71.8

Additional Room Ventillation Required

cm²

see table 4

2

C

J

H

F

K (Dia)

I

G

x 4

A

3

- 2 -

Summary of Contents for Bellingham 12kW BLM12SE

Page 1: ...te Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls Installation should only be carried out by a suitably qualified installer Di...

Page 2: ...n Bellingham 5kw Nominal heat output Wood kW 5 0 Solid Fuel Ancit kW 4 9 Efficiency Wood 84 8 Solid Fuel Ancit 85 0 CO Emission 13 O2 Wood 0 34 Solid Fuel Ancit 0 33 Flue Gas Temp Wood C 210 Solid Fue...

Page 3: ...ppliance 300mm or 1200mm from hearth whichever is greater 0mm 51 150mm 75mm 0 150mm 150 300mm 75mm 150mm 300mm No Minimum Requirement H MIN 150mm X X T T MIN 150mm MIN 125mm See Table 3 Solid non comb...

Page 4: ...11 9 10 8 CLOSURE PLATE SEAL 150mm max Fire proof seal or fire cement 150mm max C B A 4...

Page 5: ...suitable protective gloves when handling In case of contact wash immediately with plenty of water Asbestos This appliance contains no asbestos If there is a possibility of disturbing asbestos as a res...

Page 6: ...ame room as this appliance 6 Floor Protection Installation Clearances In all instances the stove must be positioned on a non combustible hearth that conforms to Building Regulations and is firm secure...

Page 7: ...rformance the stove should not be overfilled with fuel above the height of the rear brick ideally the top 1 height of the rear brick should be visible at all times Overfilling can cause poor operation...

Page 8: ...th a proprietary glass cleaner or some damp newspaper Do not use abrasive materials as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed po...

Page 9: ...ainer It is a condition of the guarantee that the installation complies with relevant Building Regulations and is carried out by a suitably qualified individual HETAS registered in England and Wales o...

Page 10: ...10...

Page 11: ...R HANDLE ASSEMBLY 4 19089 0 16 GRATE FRAME 1 70421 0 5 DOOR CATCH 1 70181 0 17 RIDDLE ARM 1 70422 0 6 DOOR GLASS 1 70100 0 18 AIR CONTROL HANDLE 1 71035 0 7 GLASS FIXING BKT 1 70101 0 19 LEG 1 70096 0...

Page 12: ...n SO30 2DF t 44 0 844 879 3588 f 44 0 1489 773050 e aftersales dimplex co uk w www dimplex co uk Northern Ireland Glen Dimplex Northern Ireland 5 Charlestown Avenue Charlestown Industrial Estate Craig...