background image

CONTROLLER: 

INDICATORS AND CONTROL BUTTONS

6

(LH) Failed to connect power consumers to the generator.

+

(RH) Failed to connect power consumers to the mains.

+

Flash together when the generator is deenergized.

+

  

  ERROR OPTIONS:

ERROR OPTIONS:

Starter indicator – signals the operation of 

the starter and flashes once per second in 

preparation for the startup.
Engine preheat indicator – glows steadily when 

the engine is preheated. The generator must be 

equipped with an engine preheating system.

Engine indicator – glows steadily when the 

engine is running. It flashes once per second in 

preparation of the engine for the startup.
(LH) Generator power indicator – lights up 

when power is supplied from the generator. It 

flashes once per second in preparation for the 

power supply.

(RH) Main power indicator – lights up when power is supplied from the mains.

Img. 2

Load connection indicator – glows steadily when 

power consumers are connected.

Connection error indicator – flashes 4 times 

per second and emits a beep when cables 

or connections are damaged.

Power indicator – lights up when there is 

voltage from the main power network. It flashes 

once per second when testing the mains.

Engine fault indicator – flashes 2 times per 

second and emits a beep after the engine 

has failed to start after 3 attempts.

Oil pressure indicator – flashes 2 times per second and emits a beep when the engine oil pressure is low. 

The generator must be equipped with an oil pressure sensor. (The ATS models do not have this function).

Battery voltage indicator – flashes 2 times 

per second in the event of improper 

battery voltage.

Engine start button – starts the engine in 

manual mode.

Engine stop button – stops the engine in 

manual mode.

Automatical mode button / indicator 

– switches the ATS unit in AUTO mode, 

lights up in AUTO mode.

Manual mode button / indicator – switches the 

ATS unit in manual mode, lights up in manual 

mode.

“Power switch” – ATS unit main switch.

www.ks-power.de/en   

|

   

4

Summary of Contents for Konner & Sohnen 4260405362066

Page 1: ...Please read this manual carefully before use Manual KS ATS 3 18 HD KS ATS 1 40 HD KS ATS 4 63 HD AUTOMATIC TRANSFER SWITCH ATS EN...

Page 2: ...t allow moisture to enter the product as this increases the risk of electric shock Avoid direct contact with grounded surfaces pipes radiators etc Be careful when working with the power cord Replace i...

Page 3: ...trol cable length m 4 4 Dimensions mm 300 400 200 Net gross weight kg 5 7 6 1 6 1 6 5 Model KS ATS 4 63 HD Battery voltage DC8 0 18 V Power consumption 10 W Voltage 230V 400V Power 230 V kW 14 4 28 8...

Page 4: ...p power source generator In case of unsuccessful startup the ATS system attempts to start the generator three times with an interval of 6 seconds between the attempts If all three attempts are unsucce...

Page 5: ...or glows steadily when power consumers are connected Connection error indicator flashes 4 times per second and emits a beep when cables or connections are damaged Power indicator lights up when there...

Page 6: ...ime can be adjusted from 3 to 21 seconds Engine start delay time following deenergization of the main power supply factory set to 12 seconds LH Generator warm up time before connecting the load factor...

Page 7: ...nnected by a qualified technician The product is live WARNING DANGER Open the ATS unit door Inside you will see the connection terminals Connect the ATS unit as shown in Figs 3 6 and according to the...

Page 8: ...pendix ITY terminals for the main power supply A Phase 1 B Phase 2 C Phase 3 N NEUTRAL OUTPUT terminals for home or other power consumers L1 Phase 1 L2 Phase 2 L3 Phase 3 N NEUTRAL GENERATOR terminals...

Page 9: ...s indicated by melting or discoloration of parts due to the effect of high temperature score marks on the cylinder or piston surfaces destruction of connecting rod inserts or piston rings In addition...

Page 10: ...www ks power de en 9 1 2 KS ATS 3 18 HD A B C N L1 L2 L3 N U V W N CITY OUTPUT GENERATOR ANNEX...

Page 11: ...www ks power de en 10 L N L N L N CITY OUTPUT GENERATOR 3 4 KS ATS 1 40 HD...

Page 12: ...www ks power de en 12 KS ATS 4 63 HD 5 6 A B C N A B C N A B C N CITY POWER LOAD GENERATOR...

Page 13: ......

Page 14: ...Deutschland Hauptstr 134 51143 K ln www ks power de info dimaxgroup de Polska DIMAX International Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de 47 02...

Reviews: