7
9. Input the RAID size, press
Enter
.
10. Press
Ctrl+E
to exit the BIOS.
11. When asked
Are you sure to exit(Y/N)?
,
press
Y
to exit and reboot.
Note:
If during boot the RAID BIOS reports an
RAID1 set is in
Rebuild status, The rebuild will continue after boot
sequence is complete
, disregard the message, continue
booting, and let the Mirror rebuild.
Rebuilding a F
ailed
Mirror Set
When a failure to one member occurs, you will be notified either by the
RAID BIOS
during boot or by the
SATARAID5 GUI
while in Windows.
The steps below will guide you in rebuilding a failed mirror set.
1. Replace the failed drive with one of equal or greater capacity,
then start the computer.
2. During boot press
Ctrl+S
or
F4
to enter the RAID BIOS.
3. Select
Create RAID Set
then press
Enter
.
4. Select
SPARE DRIVE
then press
Enter
.
5. Select the replacement drive then press
Enter
.
6. When
asked
Are You Sure(Y/N)?
, press
Y
to confirm.
7. Press
Ctrl+E
to exit.
8. When
asked
Are you sure to exit(Y/N)?
,
press
Y
to exit.
RAID 0+1 (Mir Striping)
This RAID array to be used on
New/Blank
hard drives, do not use
existing hard drive(s) with data. To create a RAID 0+1 set four hard
drives are required.