Digitronic
Analog - Digital - Converter
Automationsanlagen GmbH
AWA/2X12B
5. Terminal alllocation
.
5.1. Terminal allocation of the power supply
Terminal 1
0V voltage supply
Terminal 2
0V voltage supply
Terminal 3
+24V voltage supply
Terminal 4
+24V voltage supply
5.2. Terminal allocation of the analog input 1
Terminal 5
signal ground GND (0V)
Terminal 6
analog signal 1
as voltage or current signal
(see also chapter 6. Configuration)
Terminal 7
reference voltage output (+4.096V or +5V)
(see also chapter 6.2. Reference voltage supply)
5.3. Terminal allocation of the analog input 2
Terminal 8
Signal ground GND (0V)
Terminal 9
Analogsignal 2
as currency - or voltage signal
(see also chapter 6. Configuration)
Terminal 10 reference voltage output (+4.096V or +5V)
(see also chapter 6.2. Reference voltage supply)
Note:
All analog signals must be laid shielded and the cover has to laid to ground
on both sides.
5.4. Pin allocation of the external interface
The analog - digital - converter AWA/2X12B has an external interface via which the data transfer with
the CamCon device is done. Via the interface input the data exchange with the CamCon e.g.
DC16/50/90 or DC115 is done. Via the interface output, the data exchange with another analog - digital
- converter or a CamCon DC91 output-expansion is done. By this series connection several devices
may be connected to a CamCon. A shielded 6 pole data cable with conductors wired in pairs is
required. The maxium wiring disatance is 300 meters, the data exchange is done potentially free via
optical couplers.
DSUB 9 Pin and female plug
Pin 1,4,7
GND
Pin 2
TxD
+
Pin 8
CLK +
Pin 5
RxD +
Pin 6
TxD
-
Pin 3
CLK -
Pin 9
RxD -
CamCon DC50
AWA/2X12B
CamCon DC91
external
external
external
external
Edition: Jun. 17
Page: 6