4.0 SE74 Options: OPSW changes 

The SE74 configuration and be

-

havior can be configured using non-volatile OPSW's. The Factory default OPSW 

settings will configure most common requirements.

1. 

Press and hold the OPS button for about 3 seconds until the green ID and 

RTS LEDs blink alternately.  Release the OPS button. The SE74 is now setup 

to configure OPSW 1 to 48 by sending the required  SW# as C or T to setup 

an option.

2.  Send a SW# in range 1-48 as C/T matching the valid settings from Table 1 

OPSW settings shown below.

3.  When finished press and hold OPS button for 3 seconds to exit OPSW setup  

mode. The SE74 will now restart with the new OPSW settings.

4.  Factory default OPSW settings are shown in 

BOLD

.

5.  OPSW's not in this table are reserved and should be kept at Factory default T 

settings for predictable operation.

6.  OPSW40 =C will reset to Factory defaults on OPSW mode exit

Table 1: SE74 OPSW setting table

:

OPSW# Default=

bold

Action:

1

T

C = Slow motion turnouts, T = pulse/solenoids

5

T

C =DCC Aspect control mode, T = SW control

6

T

C =Disable internal Routes

10

T

C = Bushby bit active

11

T

C = 8 input lines trigger Routes

14

T

C = DCC SW commands only

15

T

C = Do not echo Route SW's to Loconet

16

T

C = Solenoid pulse hi CD voltage

30

T

C = Send B2 not B0 input SW messages

33

T

C = 2-wire searchlight signals (figures 8/9)

34

T

C = Searchlight, T = 3 color signals

35

T

C = Common cathode signals, T=common anode

37,36

T, T

C, T

T, C

C, C

Flashing Yellow, 4th SW aspect

Flashing Red, 4th SW aspect

Dark, 4th SW aspect

Flashing Green, 4th SW aspect

38

T

C = Disable SW1021/1022 signal broadcast

40

T

C = Set Factory defaults

41

T

C = Make Lunar aspects Persistent

Summary of Contents for SE74

Page 1: ...y wink OFF every 2 secs as a product heartbeat showing the SE74 is operational Alternatively power from DCC feeder wires to the TKA B terminals 3 Plug in an active LocoNet to a SE74 RJ12 connector The...

Page 2: ...om SW257 on that control heads 1 16 consecutively with 2SW per head Each SE74 uses 36 total consecutive SW addresses 2 The SW257 264 settings control heads 1 A1 Main 2 A2 Dwarf 3 Main B DC in Complete...

Page 3: ...74 turnouts can be Broadcast setup by turnout1 SW2041 through turn out4 SW2044 10 SW1024 C turns ON Aspect Exercise cycles SW1024 T turns OFF A double click of the ID button will toggle Exercise ON OF...

Page 4: ...e ID and OPSW LEDs will blink alternately to show one Route can be set up Release the RTS button 2 Select a switch address on your throttle between 1 and 8 and issue the command direction for Closed T...

Page 5: ...in BOLD 5 OPSW s not in this table are reserved and should be kept at Factory default T settings for predictable operation 6 OPSW40 C will reset to Factory defaults on OPSW mode exit Table 1 SE74 OPSW...

Page 6: ...nnected to LocoNet this will occur as a SW message to make the change and notify the system it has occurred Wire to momen tary press on buttons for SW control 2 The pins SENS1 SENS2 SENS3 and SENS4 wi...

Page 7: ...means the 2nd SE74 SW aspect Base would need to be 17 or higher 5 Use the LH encoder knob to scroll up and down through the detected SE74 devices with an underline shown at the 2nd SE74 6 At the 2nd...

Page 8: ...suitable DT602 plugged into LocoNet press the Menu 3 4 keys to enter Route Editor menu If any SE74 is on LocoNet the DT602 will beep after about one second and show DS7x routes at the D soft key posit...

Page 9: ...e CV s ac tually each control 8 individual OPSW bits OPSW1 is ls bit of CV11 through OPSW8 as ms bit of CV11 5 The DT602 does not indicate to the SE74 when programming is complete After finishing CV c...

Page 10: ...n for wiring detail and are not installed on the PCB test mast 4 The 3 wire Searchlights of Figures 6 and 7 are common cathode version and allow Lunar lamps to be connected for all 4 heads on an SE1 c...

Page 11: ...features available 4 For 2 wire pulse solenoids e g a Kato N crossover just wire to R G termi nals in the polarity that operates as you need Do not run more than one solenoid device per SE74 pulsed R...

Page 12: ...ty to operate under and be in compliance with CFR 47 rules as administered by the Federal Communication Commission Digitrax believes any conscientiously installed equipment following guidelines in thi...

Reviews: