![Digital View SVX-4096 Instructions Manual Download Page 7](http://html1.mh-extra.com/html/digital-view/svx-4096/svx-4096_instructions-manual_2499635007.webp)
Specifications subject to change without notice
© Digital View Ltd
– Ver 2.0 August 19, 2016 (SVX-4096_manual.doc)
Page 7 of 54
CONNECTION & OPERATION
CAUTION
: Never connect or disconnect parts of the display system when the system is powered up as this may cause serious damage.
CONNECTION
Connection and usage is quite straight forward (it is useful to have the relevant connection diagram available at this time):
1.
LCD panel & Inverter:
Connect the inverter/Backlight driver (if it is not built-in the panel) to the inverter/backlight connector of the
LCD panel.
2.
V-by-One interface panels:
The controller board supports V-by-One interface 4K panel. Plug the cable to J7 for driving 4K 60Hz
panel. And make sure the matching panel timings and correct jumper settings (JB13 & JB14) by referring to the panel
support table and jumper settings table in page 13-16.
3.
eDP interface panels:
The controller board supports eDP(1.1) or eDP(1.2) interface 4K panel. For eDP(1.1) panel, plug the cable
to J7. For eDP(1.2) panel, plug the cable to J6. And make sure the matching panel timings and correct jumper settings (JB13
& JB14) by referring to the panel support table and jumper settings table in page 13-16.
4.
LVDS interface panels:
The controller board supports LVDS interface 4K panel. Plug the cable to J2/J3/J4 for driving 4K 60Hz
panel. And make sure the matching panel timings and correct jumper settings (JB13 & JB14) by referring to the panel
support table and jumper settings table in page 13-16.
5.
Inverter/Backlight driver:
Plug the inverter/backlight cable to CNB1 and CNA1 (if necessary). Plug another end to the connector
on the inverter/backlight of panel side.
6.
Function switch & Controller:
Plug the OSD switch mount cable to CNC1 on the controller board and another to the OSD switch
mount.
7.
LED & Controller:
Plug in a 3-way with dual color LED to connector LED1 on the controller board.
8.
IR & Controller:
Plug in a 3-way with IR sensor to connector IR1 on the controller board.
9.
Jumpers & Inverter & Panel voltage:
Particularly pay attention to the settings of JA3, JA5, JA6, JB2 and JB3. JB2 & JB3 are
used for inverter control (read inverter specification and information on the jumper table to define the correct settings). JA3 &
JA5 & JA6 is used for panel voltage input (read panel specification and information on the jumper table to define the correct
settings).
10.
Input signal cable & Controller:
Plug the corresponding signal input to the connector on the controller board.
11.
Power supply & Controller:
Plug the DC 12V/24V power in to the connector PP2 or PP5. You can consider to use
DigitalView mating power cable P/N 426013710-3, 1000mm for PP5 connection.
12.
External panel power input :
Plug power cable : P/N 426013710-3 for external panel power input (3.3 (max 7A) / 5V (max 7A) /
10V (max. 5A) / 12V (max 5A) / 18V (max3.5)) for PP4 connection.
13.
Power on:
Switch on the controller board and panel by using the OSD switch mount.
General:
If you are using supplied cables & accessories, ensure they are correct for the model of panel and controller.
If you are making your own cables & connectors refer carefully to both the panel & inverter specifications and the section in this
manual, “Connectors, Pinouts & Jumpers” to ensure the correct pin to pin wiring.
PC SETTINGS
The controller has been designed to take a very wide range of input signals however to optimize the PC‟s graphics performance we
recommend choosing 60Hz vertical refresh rate
– this will not cause screen flicker.
OPERATION
Once the system has been connected and switched on there are a number of functions available to adjust the display image as
summarized in the following sections. The settings chosen will be saved for each mode independently.
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from