![Digital View HSP-1920 Instructions Manual Download Page 35](http://html1.mh-extra.com/html/digital-view/hsp-1920/hsp-1920_instructions-manual_2499627035.webp)
Specifications subject to change without notice
© Digital View Ltd – Doc Ver 1.01 : 15 Dec, 2017 (hsp-1920-manual-v101.doc)
Page
35 of 47
Hotkey 2
(1)
0xa0, “2”,
n |
“r” | “R” |
“?”
Set Hotkey 2=
Value
Reset
Query
“1” – Volume.
“2” – Back Level.
“3” – Contrast.
“4” – Saturation.
“5” – Input source.
“B” – No function
“E” – Aspect/Size
“F” – Image Orientation
“H” – Brightness
“I” – Auto Picture Setup
Runtime counter
0xa1,
nnnnn |
“r” | “R” |
“?”
runtime counter value =
nnnnn (* 0.5 hour)
Reset
Query
Runtime = nnnnn.
Colour
temperature select
0xb3,
n |
“r” | “R” |
“?”
Select colour temperature =
value
Reset
Query
Main selected.
“2” – 6500K.
“3” – 5000K.
“4” – user defined RGB values
“5” – 9300K
“6” – 7500K.(Default)
Red level for
selected colour
temperature
0xb4,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the red channel
for the selected colour temp. =
value/increment/decrement
Reset
Query
Red level for selected colour
temperature.
Range: “0””0”-“F””F”
Default: “8””0”
Green level for
selected colour
temperature
0xb5,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the green
channel for the selected colour
temp. =
value/increment/decrement
Reset
Query
Green level for selected colour
temperature.
Range: “0””0”-“F””F”
Default: “8””0”
Blue level for
selected colour
temperature
0xb6,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the level of the blue channel
for the selected colour temp. =
value/increment/decrement
Reset
Query
Blue level for selected colour
temperature.
Range: “0””0”-“F””F”
Default: “8””0”
Graphic horizontal
resolution enquiry
0xb7
Horizontal resolution (in pixels) in
3 digit hex number
“nnn” = horizontal resolution
Graphic vertical
resolution enquiry
0xb8
Vertical resolution (in lines) in 3
digit hex number
“nnn” = vertical resolution
Graphic horizontal
sync frequency
0xb9
Horizontal sync frequency (in
units of 100Hz) in 3 digit hex
number
“nnn” = horizontal frequency
Graphic vertical
sync frequency
0xba
Vertical sync frequency (in units
of Hz) in 3 digit hex number and
1 char
“nnnc” = vertical frequency
nnn = 3 digit hex
c= “i” or “p”
interlace or Progressive
OSD turn off
0xbd
Turn off the OSD.
“0” – fail.
“1” – successful.
Backlight control
0xe0,
nn | “+” | “-” |
"="|
“R” | “r” |
“?”
Set Backlight =
value/increment/decrement
Display OSD indicator
Reset
Query
Backlight.
Range:
D/A : “0””0” ~ “6””4”
100Hz : “0””0” ~ “6””4”
120Hz : “0””0” ~ “6”"4”
140Hz : “0””0” ~ “6””4”
160Hz : “0””0” ~ “6””4”
180Hz : “0””0” ~ “6””4”
200Hz : “0””0” ~ “6””4”
220Hz : “0””0” ~ “6””4”
240Hz : “0””0” ~ “6””4”