Digital Monitoring Products X1 Series Quick Start Manual Download Page 3

X1 ELEVATOR CONTROLLER QUICK START GUIDE  |     DIGITAL MONITORING PRODUCTS

DETERMINE COMMUNICATION

For more detailed information, follow the QR code at the end of this guide to see the 

full X1 Series Elevator Controller Installation and Programming Guide: LT-2463.

Ethernet Connection

Connect an Ethernet cable from the LAN/WAN connection to the X1 Ethernet port.

Cellular Connection (Optional)

1. 

Plug the included standoff into the Elevator Controller board.

2. 

Plug the cell module onto the standoff.

3. 

Plug the cell module into the cell header.

4.  Screw on the cell module antenna cable to 

the antenna connector.

5. 

Run the cable around the 505-12 Power 

Supply. 

6.  Attach the antenna with the nut on the 

inside of the enclosure and the washers on 

the inside and the top of the enclosure.

Wi-Fi Connection

If not connecting over Ethernet, the Elevator 

Controller will connect over Wi-Fi after power up.
For installing the Wi-Fi Antenna, follow the QR code at the end of this guide to see the 

full X1 Series Elevator Module Installation and Programming Guide: LT-2463.

 

Note: 

You can connect over Ethernet or Wi-Fi, but not both at the same time.

Ethernet 

Port

PoE

Headers

Cell

Header

Standoff

Location

APPLY POWER

 Warning:

 Refer to your local state regulations before connecting to building 

power. Wiring methods shall be in accordance with NEC, NFPA #72, ANSI, and 

with all Authority Having Jurisdiction.

Wire the Input Power

Connect the transformer wires to terminals 1 and 2 on the PCB. Ground yourself and 

apply power to the Elevator Controller.

Wire the Battery

DMP recommends using a 9 Ah battery. Connect the black battery lead to the negative 

battery terminal. Connect the red battery lead to the battery positive terminal. 

Observe polarity when connecting the battery.

Summary of Contents for X1 Series

Page 1: ...EADER The X1 Series provides direct 12 VDC output to the reader on the RED terminal connection The elevator service company supplies traveling cable wires for the reader Document which numbered conductors are connecting to which terminals on the elevator controller Terminal Name Wiegand Function OSDP Function R1 R2 12V DC W1 W2 Data 1 B 485 G1 G2 Data 0 A 485 B1 B2 12V ground DC LC LED Control N A...

Page 2: ... as sounders lights or sirens These are 12 VDC outputs Aux Output 1 2 O1 O2 Attach the negative wire of the device here 12V 12V Attach the positive wire of the device here AC DC BAT R1 W1 G1 B1 LC BC R2 W2 G2 B2 LC BC DS RX CI G 01 02 12V NC C NO 01 02 12V X1 Elevator Controller WIRE OPTIONAL INPUTS AND OUTPUTS Onboard Inputs Door Switch DS Normally Closed This terminal is not typically used for e...

Page 3: ...re Wi Fi Connection If not connecting over Ethernet the Elevator Controller will connect over Wi Fi after power up For installing the Wi Fi Antenna follow the QR code at the end of this guide to see the full X1 Series Elevator Module Installation and Programming Guide LT 2463 Note You can connect over Ethernet or Wi Fi but not both at the same time Ethernet Port PoE Headers Cell Header Standoff Lo...

Page 4: ...ttings PROGRAM IN DEALER ADMIN Go to Dealer Admin dealer securecomwireless com to program the controller TEST THE CONTROLLER Make sure that the Reader LEDs are on and the Elevator Controller s Power LED is on If connected to Wi Fi the Wi Fi LED is on solid If connected to network the Network Port light is blinking For cell and all communication methods check that the elevator controller is communi...