background image

Cabling (continued)

DECserver  900TM

                                   9

Table 2 describes the cable connections that are compatible with the DECserver 900TM

Ethernet and serial line connectors. Wiring diagrams of individual cables are shown on

page 11.

  

H8584ĆAC MP8 to MMJ adapter

Use this adapter to convert a serial port to

a DECserver 300 terminal server configuĆ

ration.

Use this office cable to connect from the

6Ćpin MMJ port of a terminal or printer to

the 8Ćpin MJ faceplate data connector.

The BN24H is configured with one 6Ćpin

modified modular plug, one standard

8Ćpin plug, and crossover wiring.

BN24H MP8 to MP6 office cable

H8585ĆAB

1

MJ8 to DB25 (male)

modem adapter

H8585ĆAC

1

MJ8 to DB25 (male)

modem adapter

          

BN25G MP8 to MP8 equipment cable

Use this cable as either a patch cord or

office cable. It is configured with stanĆ

dard 8Ćpin modular plugs, which connect

four unshielded twisted pairs pinĆtoĆpin.

1

Adapters H8585ĆAB and H8585ĆAC are not for connection to public works in Sweden, Germany, or Japan.

H8585ĆAA MJ8 to DB9 (female)

nullĆmodem adapter

Use this adapter with the BN25G cable to

convert the DECserver 900TM connector to

the DB9 connector for cabling to PC asynchĆ

ronous ports.

Use this adapter with the BN25G cable to

connect lowĆspeed modems to the DECservĆ

er 900TM.

Before connecting cables to the DECserver 900TM ports, you must verify supported modem
signals with the person managing the DECserver 900TM.  This information is necessary to
determine what cables to use.  For more information on the signals, refer to the 

Network

Access Server Management manual.

Use this adapter with the BN25G cable to

connect highĆspeed modems to the DECĆ

server 900TM.

Summary of Contents for DECserver 900TM

Page 1: ...area network LAN It operates in a DEChub 900 MultiSwitch or as a standa lone access server The DECserver 900TM is configured with 32 MJ8 RJ 45 con nectors and provides limited modem control with the...

Page 2: ...nd to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such radio frequency interference...

Page 3: ...Provides error and status information 6 Flash RAM Slot Provides an opening in which to insert the Flash RAM card 7 Reset Switch Resets the module to factory defaults To reset while turning on the powe...

Page 4: ...e DEChub 900 MultiSwitch to accommodate this module s power rating You may have to add another power supply to the DEChub 900 MultiSwitch to accommodate this module without affecting other modules alr...

Page 5: ...fter the module completes self test Connect the port cables to any available port connector on the module Connect the port cables LKG 8091 93I LKG 8090 93I Module installation is complete Notes Port 1...

Page 6: ...d the Flash RAM card protrudes from the front panel about 1 4 inch The Flash RAM card is keyed and cannot be inserted improperly The Flash RAM card can be hot swapped and may be inserted or removed at...

Page 7: ...7 Remove the module from the DEChub Disconnect the port connector cables from the module a Lift the release lever on top of the hub slot b Pivot the module back on its bottom mounting tab until it di...

Page 8: ...o the DECconnect System Planning and Configuration Guide 1 For cable type H8245 A or H8246 B 24 AWG 4 pair twisted pair EIA 432 A V1 0 4 8 K 1600 ft 9 6 K 900 ft 19 2 K 500 ft 38 4 K 280 ft 57 6 K 100...

Page 9: ...e this cable as either a patch cord or office cable It is configured with stan dard 8 pin modular plugs which connect four unshielded twisted pairs pin to pin 1Adapters H8585 AB and H8585 AC are not f...

Page 10: ...XD GND CTS RI DSRS TXD DTR DSR CTS or RI Selected by software RTS or DSRS DSR or DCD RTS DCD Table 3 DECserver 900TM Serial Line Ports Signal Name Software Default1 Software Alternative1 1 To change d...

Page 11: ...GND DSR RXD RXD GND TXD GND TXD DTR CTS 8 7 6 5 4 3 2 1 6 5 4 3 2 1 8 Pin Modular Plug 6 Pin Modular Plug DSR DTR TXD TXD GND RXD RXD GND DSR RXD RXD GND TXD GND TXD DTR Twisted pairs 1 2 3 4 5 6 7 8...

Page 12: ...ipment Corporation Module OK LED is flashing Non fatal error See the error message on the console port Seven segment display is Memory failure Return the unit to Digital flashing C d or n Equipment Co...

Page 13: ...Requesting dump Dumping Hardware revision incompatible with firmware revision No SIMs or wrong type SIMs installed DECserver 900 is operating correctly The rotating code is referred to as the race tra...

Page 14: ...ascii command to specify that you are retrieving ASCII text files 6 Use the get command to get the file or files that you require 7 When you are finished use the quit command to log out Note that user...

Page 15: ...r Sound Pressure Sound Power Sound Pressure ISO 77792 Level LWAd B Level LpAm dBA Level LWAd B Level LpAm dBA DSRVZ 4 7 33 DSRVZ DEHUM 5 1 37 Schallemissionwerte Leerlauf Betrieb Leerlauf Betrieb Wert...

Page 16: ...g manual Describes problem solving tools and procedures for the various network access servers DECserver Network Access Software Installation VMS Describes how to install the network access server sof...