11
NUMBER OF DIGITS
J6
J5
RELAY OUTPUT MODE
J3
J4
1
X
X
LATCHING
O
O
2
X
O
MOMENTARY
X
O
3
O
X
ALTERNATE
O
X
4
O
O
MOMENTARY OUTPUT
FOR BOTH ON & OFF
X
X
X
= JUMPER INSTALLED
O
=
JUMPER REMOVED
R12
= INPUT SIGNAL LEVEL RANGE ADJUSTMENT
JUMPER
OPEN
SHORTED
INPUT IMPEDANCE
J2
10k
Ω
◼
600
Ω
INPUT
TERMINATION
J1
BALANCED
UNBALANCED
◼
5 MINUTE
RESTORAL
J7
ENABLED
◼
DISABLED
MOMENTARY
OUTPUT FOR BOTH
ON & OFF
J3, J4
DISABLED
◼
ENABLED
◼
= FACTORY SETTING
FIGURE 3
Jumper Locations