background image

13 

 

The programming of jumpers for the output relay is shown below. Consult FIGURE 3 page 7 for the 

'J3'

 

jumper and the 

'J4'

 jumper location. 

 

RELAY OUTPUT 
MODE 

JUMPER 

J3 

J4 

LATCHING 

MOMENTARY 

ALTERNATE 

MOMENTARY  
OUTPUT FOR BOTH 
ON & OFF 

TABLE 2 

X = JUMPER INSTALLED 

O = JUMPER REMOVED  

Number of Digits to Decode:

 

The  3185E  is  factory  set  to  decode  a  4-digit  'ON'  code  sequence  and  a  4-digit  'OFF'  code  sequence. 

The first three digits of the code sequence are the same for both 'ON' and 'OFF'. The fourth digit for the 
'ON' code sequence is factory set to '*', and the fourth digit for the 'OFF' code sequence is factory set to 
'#'. The number of digits to decode is determined by jumpers 

'J6'

 and 

'J5'

. Consult FIGURE 3 page 7 for 

the location of 

'J6'

 and 

'J5'

The programming of jumpers for the number of digits to decode is shown below: 

NUMBER OF 
DIGITS 

JUMPER 

J6 

J5 

TABLE 3 

X = JUMPER INSTALLED 

O = JUMPER REMOVED  

Fourth Digit ON/OFF:

 

The fourth digit of the 'ON' code sequence and the fourth digit of the 'OFF' code sequence are factory 

set  at  '*'  and  '#'  respectively.  To  enable  user  selection  of  the  fourth  digits,  it  is  necessary  to  remove 
resistor  ‘R8”  and  install  two  additional  selection  switches,  S4  and S5,  plus IC  A3.    When ordering  the 
switches, please use Digital Alert Systems 

part number ‘9200002’ for each of the two switches and part 

number ‘9120375’ for the IC required. 

Consult  the  PC  board  layout  in  Figure  1,  on  Page  4,  for  the  location  of  the  parts  to  be  removed  and 

inserted. 

Summary of Contents for 637

Page 1: ...ly closed NC as desired connections on the terminal block 3 The connections on the terminal block for RELAY 1 and RELAY 2 are separate contacts but are part of the same relay 4 The SET and RESET conne...

Page 2: ...ress implied or statutory including without limitation the implied warranties of merchantability and fitness and including but without being limited to any obligation of Digital Alert Systems with res...

Page 3: ...Digital Alert Systems 100 Housel Ave Lyndonville NY 14098 phone 585 765 2254 fax 585 765 9330 digitalalertsystems com Printed in USA Copyright Digital Alert Systems Inc Specifications subject to chang...

Page 4: ...onnection 9 Power Supply Input 9 CUSTOMER OPTIONS 10 FIGURE 3 Jumper Locations 11 Input Impedance 12 Input Balanced Unbalanced 12 5 Minute Restoral 12 Momentary Output for ON and OFF 12 Output Relay 1...

Page 5: ...features include Dual Form C Relay Output Selectable Input Impedance Selectable Balanced Unbalanced Input Adjustable Input Signal Range Restoral of Output Status if Power Interruption is Less Than 5 M...

Page 6: ...dBm 155mV to 489 mV Optional 10 dBm Adjustable Digit Validation Time 40 ms Minimum Inter Digit Time Minimum 40 ms Maximum 3 Seconds Maximum Digits Per Second No Twist 13 6 dB 12 Relay Output DPDT 30...

Page 7: ...Common terminal for relay output referenced to pins 9 and 10 2 Circuit common ground 3 Circuit common ground 5 Audio input low audio input circuit common if unbalanced 6 Audio input high 8 12 Volt D C...

Page 8: ...8 FIGURE 1 Edge Connector Switch and Indicator Locations and Modifications for 4 digit ON OFF Operation FIGURE 2 Block Diagram...

Page 9: ...5E to reset This input is level sensitive and requires a minimum pulse of 20 msec to circuit common to reset the card The Reset input dominates over all other functions NOTE The 3185E will ignore all...

Page 10: ...ng Input Impedance 10 k Input Unbalanced 5 Minute Restoral Enabled Momentary Output for ON and OFF Disabled Output Relay Latching 4 Digit Decode Sequence for Fourth Digit ON for Fourth Digit OFF Jumpe...

Page 11: ...UTPUT FOR BOTH ON OFF X X X JUMPER INSTALLED O JUMPER REMOVED R12 INPUT SIGNAL LEVEL RANGE ADJUSTMENT JUMPER OPEN SHORTED INPUT IMPEDANCE J2 10k 600 INPUT TERMINATION J1 BALANCED UNBALANCED 5 MINUTE R...

Page 12: ...the 3185E may be set in three different modes of operation latching momentary or alternate action toggling The 3185E is factory set to latching Being set at latching means the output relay will energ...

Page 13: ...s to decode is determined by jumpers J6 and J5 Consult FIGURE 3 page 7 for the location of J6 and J5 The programming of jumpers for the number of digits to decode is shown below NUMBER OF DIGITS JUMPE...

Page 14: ...This LED indicator will continue to illuminate until a valid DTMF digit is detected or DC power is removed from the board The Valid Sequence LED CR15 will illuminate upon the decoding of a correct DT...

Page 15: ...nce for ON SWITCH 3 second digit for code sequence for OFF If the 3185E is programmed for momentary relay output or alternating relay action SWITCH 3 is not used for programming Operating With a 1 Dig...

Page 16: ...mplied warranties of merchantability and fitness and including but without being limited to any obligation of Digital Alert Systems with respect to incidental or consequential damages or damages for l...

Reviews: