Maintenance Guide 
Veterinary Dental Cassette Kit 

  TM-723-EN 

General Safety Guidelines 

All the safety and operating instructions should be read carefully before this device is operated. 

This device has been designed and tested to meet strict safety requirements applicable to 

medical equipment, and has been supplied in a  safe condition.  To  ensure personnel and 

patient safety,  the device shall be operated and serviced in compliance with all procedures, 

warnings and precautions during all phases of operation and service of this device.  Failure to 

comply  to  with  safety  guidelines  may  result  in  injury  to  service  personnel,  operator,  or  patient. 

Digiray 

Corp.

 assumes no liability for failure to comply. 

If this device is not used as specified, the protection provided by the device could be impaired. 

This device must be used in a normal condition only. 

Installation, service and operation of this device should only be undertaken by qualified trained 

personnel.  The operator should study instructions and precautions carefully before starting to 

use the device listed here and throughout the manual.    

There are no user serviceable parts inside this device.  The device should only be opened and 

serviced by qualified service personnel.  Failure to heed this warning may result in injury to 

service  personnel  or  damage  to  equipment,  and  void  any  and  all  warranties.   If  there  is  a 

service problem, please contact 

Digiray

 Corp.

 or authorized dealer. 

Do not spill liquids on the device, and never operate the device in a wet environment. 

Keep the device from radiators and heat sources. 

Use the device only with accessories supplied with this device. 

This  device is  intended  to  be  grounded.  Plug  power  cord into  properly  grounded  electrical 

outlets.  This cord is equipped with three-prong plugs to help ensure proper grounding. 

This  device  contains  static  sensitive components.   Proper  static  handling procedures  and 

equipment must be used when servicing this device. 

Summary of Contents for Fire CR

Page 1: ...not necessarily represent standards or specifications which must be met by Digiray Corp All information contained herein is intended for guidance purposes only and characteristics of the products and...

Page 2: ...Cassette Kit TM 723 EN 2 Contact Digiray Corp 825 Unitech Venture Town 142 Ilsan ro Ilsandong gu Goyang si Gyeonggi do 10442 Republic of Korea Tel 82 31 932 8401 Fax 82 31 927 9988 Website www digira...

Page 3: ...ges have been made to delivered system and accessories the warranty by Digiray Corp becomes void Digiray Corp will not accept any responsibility or liability for the proper functioning of the product...

Page 4: ...nd operation of this device should only be undertaken by qualified trained personnel The operator should study instructions and precautions carefully before starting to use the device listed here and...

Page 5: ...ccur unplug the device from the electrical outlet and contact authorized service personnel The power cord or power adapter is damaged An object has fallen into the device The device has been exposed t...

Page 6: ...e 4c 48x54 mm 2ea 6 Size 4 76x57 mm 1ea Veterinary Dental Cassette Moving Plate 2 Imaging Plate Cleaning Protect your investment Dust and dirt are piled up on CR imaging plate leading to image artifac...

Page 7: ...e surface of the protective layer and they appear on the image The phosphor layer has peeled away from the support layer 2 2 Imaging Plate Cleaning Tools Moving plate extracting tool Imaging plate cle...

Page 8: ...tte the Cassette Lock Releaser should be linked up with the Cassette The the Cassette Lock Releaser are pressing those buttons during it is linked up with the Cassette correctly Stand the Cassette on...

Page 9: ...hanol directly on to the imaging plate Make sure the imaging plate surface is completely dry before using the imaging plate WARNING Be sure not to damage the imaging plate Do not scratch the imaging p...

Page 10: ...ck Releaser Make sure both of buttons are pressed Insert moving plate into the cassette WARNING Do not put the imaging plate upside down when it is inserted Do not insert the moving plate in wrong dir...

Page 11: ...Kit TM 723 EN 11 DANGER Never press push buttons of the cassette with upside down position A crash will cause the damage of the imaging plate and moving plate which can affect X ray image quality Alw...

Reviews: