background image

 

Height  adjustment     

For  the  height  adjustment  to  be  possible,  the  four  adjusting  screws 

provided  in  the  small  accessory  box  must  be  fitted  as  in  fig.  9  on  page  7, 

before

 

mounting the machine to the steel base plate. Ideally, these screws should protrude 5 to 
10 mm, creating a gap between the base plate and the under side of the machine. This 
will allow for subsequent height adjustment. 
 

Wiring   

For all connections refer to Fig. 1. 

Mains.      A  suitable  cable  (armoured  3-core  or  Surfex)  should  be  used  from  a  2-

amp 

circuit  breaker  on  the  distribution  board  to  the  site  of  the  motor,  where  it  is 
brought  up  through  the  opening  in  the  base  plate.  See  page  5  Fig.  4.  Connect 
the earth wire 

and

 the armour to the spare lug provided on the chassis earthing 

point.  Connect  the  Line  and  Neutral  wires  to  the  terminals  ‘L’  and  ‘N’  on  the 
controller, shown as ‘230V MAINS’ in Fig. 1. 

 

PROGRAM DISPLAY

PLUGGABLE MEMORY

ENTER BUTTON

SELECT BUTTON

TYPE

STANDARD

PARTIAL

CONTROL

LOCK

LIGHT

0V-COM

BEAM N.C.

BEAM 24V+ BEAM 24V+

COMMERCIAL

STOP

BEAM N.C.

0V-COM

CLOSE

OPEN

PARTIAL

ON/
OFF

GATE

STATUS LED+

STATUS LED+

GATE

MAINS

LAMP

BATTERY MOTOR

230V~

24V DC

L N N L

+ - + -

MANUAL

ENCODER

Fig. 1

0V-COM

ANTENNA

 

Accessories. 

Before  connecting  any  accessories,  decide  which  ‘Type’  of  operating  mode  will  be 
used,  ‘Standard’  or  ‘Commercial’.  ‘Standard’  is  suitable  for  residential  purposes,  giving 
each user full control of the gate. ‘Commercial’ avoids conflicting inputs by providing a 
dedicated ‘Open’  input  for  the users. Separate ‘Stop’ and ‘Close’ connections are also 
provided. 
  

Note:

  All the accessories are referenced to ‘0V-COM’. 

N.C.  and  N.O.  refer  to  switch  contacts,  and  stand  for  ‘Normally  Closed’  and 
‘Normally Open’. 

 

Partial.  

 For pedestrian use, a key Switch may be connected to ‘Partial’. 

This switch will cause the gate to open to a width of about 1,2m. Once partially opened, 
the  gate  may  be  re-closed  using  the  same  switch,  or  it  will  auto-close  in  the  time 
selected (5, 10 or 20 seconds) or in 5 seconds if Auto-close is not selected. 
If  the  gate  is  closing  after  being  partially  opened  and  the  safety  beam  is  blocked,  the 
gate will only re-open to the partially open point. 
 

Summary of Contents for ROBO 24

Page 1: ...se none 5 10 or 20 seconds Safety beam selection Obstacle Sensing Level Recording Remote controls up to 16 and Type of operation which may be Standard Residential or Commercial On board Radio Receiver The controller has a Digitronic e Key receiver on board that provides state of the art secure access control using Keeloq code hopping technology The receiver stores up to 16 transmitters in non vola...

Page 2: ... LIGHT 0V COM BEAM N C BEAM 24V BEAM 24V COMMERCIAL STOP BEAM N C 0V COM CLOSE OPEN PARTIAL ON OFF GATE STATUS LED STATUS LED GATE MAINS LAMP BATTERY MOTOR 230V 24V DC L N N L MANUAL ENCODER Fig 1 0V COM ANTENNA Accessories Before connecting any accessories decide which Type of operating mode will be used Standard or Commercial Standard is suitable for residential purposes giving each user full co...

Page 3: ...The installation of Safety Beams is strongly recommended especially if Auto close is to be used If Auto close is selected and Safety Beams are not fitted the gate will not operate unless a wire link is fitted from 0V COM to Beam N C This is however not advised Gate Status An LED fitted to the intercom in the house and connected to Gate Status LED will indicate the status of the gate by illuminatin...

Page 4: ...lay will show P Thereafter every press of the SEL button will cause a different letter to appear each representing different features When the required letter appears press ENT to program that feature and the letter will start flashing Use SEL to step through the setting options and ENT to confirm the selection After the display returns to P press ENT to exit Limits L 1 As above press ENT and SEL ...

Page 5: ...e gate is obstructed while closing the gate will stop reopen at slow speed and bump the open rail stop to re calibrate itself If the gate is obstructed while opening the gate will simply stop When the gate next closes it will do so at slow speed and bump the closed rail stop to re calibrate itself Commercial Type If selected as a Commercial Type the controller regards all signals from remote contr...

Page 6: ...inutes Accessories Connect the accessories as indicated referenced to 0V COM All inputs excepting the Beam are Normally Open If an off board Receiver is to be used connect it to BATTERY and and the N O output to CONTROL OPEN The common of the receiver must be linked to negative Note 1 Do not use 12v devices by connecting them to one of the batteries as this will cause improper charging Note 2 The ...

Page 7: ...Start with this setting on 1 and increase it if during normal running the gate stops and reverses while closing Record Remote r 1 Press SEL until r is displayed 2 Press ENT and the display will flash r n for new remote 3 Press the desired button on the e key Remote The decimal point on the display will flash 4 Release the button and r C will flash C for confirm 5 Press the same button to confirm t...

Reviews: