ADV-SETUP (ADVANCED SETUP) PARAMETERS
The following is a list of parameters that can be adjusted. For each parameter you can see the
range of values, the factory setting (default) and the unit of measure.
n Name
Description
Range
Default Units
1
THEV
thermal detect vario thres.
0 - 25
0.5
m/s
2
THET
thermal detect time thres.
1 - 30
10
sec
3
EFF
instant efficiency average
1-30
10
sec
4 TELE
not
used
OFF
OFF ---
5 POLA
active
polar
OFF/P1/P2/P3 OFF ----
6-8
P1-A P1-B P1-C
polar 1 coeff.
xxx
----
9-11
P2-A P2-B P2-C
polar 2 coeff.
xxx
----
12-14
P3-A P3-B P3-C
polar 3 coeff.
xxx
----
15 MCRA
McCready value
0.2 - 30
10
min
16 MCRE
McCready equiv average time 0.1 – 3
0
sec
10.7
RESTORE FACTORY SETTINGS
To restore the factory settings (default parameters) and default screen setups, press and
hold down the
key as you turn vario on. Keep the
key pressed until a message
“FACTORY SET?” appears, then confirm with “YES” or “NO”.