![Digifly Archimede Plus User Manual Download Page 30](http://html.mh-extra.com/html/digifly/archimede-plus/archimede-plus_user-manual_2497241030.webp)
Page 30
10.5
SETUP PARAMETERS
The following is a list of parameters that can be adjusted. For each parameter you can see the
range of values, the factory setting (default) and the unit of measure.
n Name
Description
Range
Default Units
1
CTRS
display contrast setting
40 - 60
53
%
2
V.UP
acoustic vario lift setting
0 - 25
0.05
m/s
3
V.DN
acoustic vario sink setting
0 - 25
3.5
m/s
4
TONE
acoustic vario tone modulation
SFT/STD/FAS
STD
----
5
RVAR
acoustic vario reactivity
0.1 - 3.0
0.4
sec
6
INTE
vario integrator
0 - 60
1
sec
7
FS_V
graphic vario scale(1,6,12 m/s) LOW/MED/HIG
MED
----
8 SIMV vario
simulator
ON/OFF
OFF ----
9
STAL
stall alarm level
0 - 150
0
km/h
10
TEC
total energy compensation
0 - 100
0
%
11 KIAS air
speed
calibration
50 - 200
100
%
12
KBAR
barometer calibration
+/- 20.0
0
mB
13
BARX
graphic altimeter x scale
0.4 – 4.0
1
minute
14
BARY
graphic altimeter y scale
3 - 3000
30
mt
15
HOUR
time setting: hours
0 - 23
----
hour
16
MIN
time setting: minutes
0 - 59
----
minute
17
DAY
time setting: day
1 – 31
----
day
18
MONT
time setting: month
1 – 12
----
month
19
YEAR
time setting: year
0 – 99
----
year
20 PILO pilot
name
6
characters ----
----
21 RECM recorder
mode
AUT/ALW/OFF AUT
----
22
R-DS
autorecorder meter
1 - 30
2
mt
23
RECR
recorder rate
1 - 60
1
sec
24
GTYP
glider type
6 characters
----
----
25 GID
glider
id
6
characters ----
----
26 U-AL altimeter,
variometer
units
FT/MT
MT
----
27 U-SP air
speed
units
MHP/KMH
KMH ----
28 U-TE temperature
units
FAR/CEL
CEL
----
29
KTMP
temperature calibration
-20.0 +20.0
0
°C
30