Digiflex RF160 Installer'S Reference Manual Download Page 4

Page  

  

 P/N: RF160IRG  Rev 1.0

E&OE   

Copyright © 2021

Receiver LED Indicators

The RF160 2 Channel SMART RF Wireless Output Module includes RED and GREEN LED indicators which provide 

visual feedback during system operation.  See Table 3 for information on the indicator colours and meanings.

LED Indicators

Lable

LED Colour

Purpose

Meaning

RLY1

Red

RLY1 Operation / 

Programing

Turns on when the relay is operated.

RLY2

Red

RLY2 Operation / 

Programing

Turns on when the relay is operated.

RF

Green

Packet Receive / 

Transmit / Power

Indicates power on the module and receive/transmit data packets.

PGM

Red

Programing Mode

Blinks each time the system is polled by the control panel.

Table 3: RF160 Device LED’s

Test RF Device

Outputs > RF Output

Test RF Device

MENU  4-3-2

This menu allows the installer to test RF160 module 

output for signal level.
1) 

Press [MENU] + [4] + [3] + [2] and use the up and 

down arrows to highlight the output in the list, 

then press [OK]. 

 

Op1 External Siren

Op2 Strobe Light

Op3 Smoke Sensor PWR

Press 



 OK or MENU

2) 

The keypad will display the current RF160 ID.

 

Op6 Garage Door

Waiting for Trigger!

Press OK or MENU

3) 

Press and hold both relay buttons on the RF160 

module to transmit a packet (signal).

 

Op6 Garage Door

Rx3 Packets=001 v2.02

Signal Good <247>

Press OK or MENU

4) 

Press [OK] or press [MENU] to exit.

The keypad will display the receiver address that re-

ceived the packet (signal) from the RF160, the packet 

count, the firmware of the RF160 and the signal strength.

Devices > RF Devices

RF Site Key

MENU  6-2-9

This menu allows the installer to set the site key to lock 

Digiflex Smart RF sensors to the control panel. 
The RF Site Key has been added to lock Smart RF devices 

to a specific site. Once a device is registered to a site, it is 

locked to the RF Site ID and cannot be learned or operated 

on any other site. 
To relearn a device onto a different site with a different 

RF Site ID, you must first remove power or the battery to 

reset the RF device, and it will then learn to any new site. 

The factory default RF site key is the serial number of the 

control panel. When upgrading panel firmware the RF 

Site ID is not changed and will need to be programmed 

if required.

Summary of Contents for RF160

Page 1: ...Installer Reference Guide RF160 2 Channel SMART RF Wireless Output Module 433MHz Rev 1 0 RoHS ...

Page 2: ...xposed to moisture or high humidity Reception distances are generally improved with higher mounting locations and with no metal ob jects near the unit If range is not achievable due to environmental or specification limitations then look at relocating the unit to a more appropriate location Receiver Operation The RF160 will turn on the green RX LED to indicate the unit is powered and it will blink...

Page 3: ...or 0F9105130 Press OK or MENU 4 Press OK to save and exit or press MENU to exit without saving Relay 1 Relay 2 Exit Press OK or MENU 5 Select Relay 1 to use relay 1 or select Relay 2 to use relay 2 of the RF160 module then press OK to save and exit or press MENU to exit without saving Delete RF Device This menu allows the installer to delete a relay on the RF160 module This menu does not delete th...

Page 4: ...oke Sensor PWR Press OK or MENU 2 The keypad will display the current RF160 ID Op6 Garage Door Waiting for Trigger Press OK or MENU 3 Press and hold both relay buttons on the RF160 module to transmit a packet signal Op6 Garage Door Rx3 Packets 001 v2 02 Signal Good 247 Press OK or MENU 4 Press OK or press MENU to exit The keypad will display the receiver address that re ceived the packet signal fr...

Page 5: ...ion Diagram Connection Diagram Antenna connects here Relay 1 terminal connections are used to connect to a 3rd party device Relay 2 terminal connections are used to connect to a 3rd party device Relay 1 and Relay 2 can be manually operated by pressing their respective buttons Power input A C or D C 9 28 V ...

Page 6: ... a terminal cover The top cover is fixed to the base using a Phillips head screw The top cover needs to be removed to install the wire antenna The terminal cover is a press fit allowing easy removal Once the wiring and programming has been completed the cover should be reinstalled to help prevent the ingress of insects and other debris Wall Mounting A wall mounting tab is located on the inside of ...

Page 7: ...ision X Solution 6000 V2 53 18 or higher Dimensions 114mm W 128mm W with Mounting Tab 62mm D 28mm H Environment 0 to 49 C Indoors Fixing Method Using mounting screws fix unit on a vertical surface in portrait orientation Relay Outputs Contact Rating 1A 30V D C Warranty 3 years from date of manufacture return to base RoHS In the interest of ongoing product development this document is subject to ch...

Page 8: ... Digiflex Pty Ltd P N RF160IRG Rev 1 0 DIGIFLEX PTY LTD 18 Brumby Street Seven Hills NSW 2147 AUSTRALIA Phone 612 97417000 Email sales digiflex com au www digiflex com au Our Vision Is Your Peace Of Mind Made in Australia ...

Reviews: