background image

Product Manual

Summary of Contents for catrax automatic master

Page 1: ...Product Manual...

Page 2: ......

Page 3: ...d stored in a retrieval system translated into any language or computer language in any electronic magnetic optical chemical manual way or otherwise without the express written permission from Digicon...

Page 4: ...6 3 Operational pictogram kit 6 4 Orientation pictogram kit 6 5 Power Supply 6 6 Electromechanical counter kit 6 7 Control Board 6 7 1 Inputs 6 7 1 1 Return signals 6 7 1 2 Electromagnets 6 7 1 3 Sou...

Page 5: ...tes something Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremel...

Page 6: ...of its technical features as well as a prolonged service life This product does not present sealing against the rain that is it is designed to be used indoors Keep this manual for future consultation...

Page 7: ...he mounting rack is done through a key with secret whose removal and insertion are extremely easy A plastic cover and a stainless steel sheet compose the upper panel The cover made of injected plastic...

Page 8: ...uts depending on the passage direction If this signal is recognized the equipment will allow the turning of the arm of Automatic Master After half of the turning is complete 60 degrees a 400 milliseco...

Page 9: ...installing and assembling the turnstile A checklist that works as a guide during inspection accompanies all Digicon packages See below the parts that can compose Automatic Master OPERATIONAL PICTOGRA...

Page 10: ...TION For more details on the dimensions of Automatic Master s components see item 8 Technical characteristics Once you observe these recommendations proceed to the installation 1 rill the floor with 3...

Page 11: ...st be fastened to the maximum to ensure good fixation All three arms must be fixed in the same upper central point Repeat the operation on the three arms and make sure all arms are well fixed INFORMAT...

Page 12: ...for opening Automatic Master after assembly 1 Unlock the two extremities of the Automatic Master using the key provided alongside the product Remove the external covers which are pressed into place Th...

Page 13: ...the equipment structure contains a device that maintains the cover in the vertical position see detail 4 The following image shows Automatic Master with all covers open INFORMATION To access the colu...

Page 14: ...l connections In one of its columns the turnstile has circuit breakers in its columns where the power cables electrical supply and the ground wire must be connected Ground wire Electric network CAUTIO...

Page 15: ...ach of these items 6 1 Rear closure kit Automatic Master can be provided with a panel to close the rear space between the columns The sheet can be of 6 mm tempered glass 6 mm acrylic or and 1 2 mm sta...

Page 16: ...d and a storage box The image below shows the items that accompany the collecting box kit 6 2 1 Connection of collecting kit to control board 16 12 11 10 9 8 7 6 5 4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1 B...

Page 17: ...Pictogram Kit The operational pictogram kit visually signals the direction of passage green arrows or the blocking red X on the upper part of Automatic Master TIP To obtain information on the configu...

Page 18: ...ent s performance Besides the input and output voltages indicated in the image below the supply has a short circuit and overheating protection PHASE NEUTRAL GROND WIRE GND 24V 3A DC INPUT 100 a 240 VA...

Page 19: ...ly suited for the Automatic Master s needs and it is one of the best options for the equipment s operation The following images show the control board with its straps connectors and dipswitch as well...

Page 20: ...anode CN7 AUDIO 1 SIGNAL 2 GND Cn8 INPUTS 1 vext1 enables turn through voltage 2 HAB1 enables turn through dry contact from right to left 3 GND 4 Vext2 enables turn through voltage 5 HAB2 enables turn...

Page 21: ...NPN CN10 SOL BQC 1 24V c d 2 SIGNAL CN14 BQC SENSOR 1 2 4V c d 2 SIGNAL CN18 ELECTROMAGNETS 1 electromagnet 1 2 electromagnet 1 3 electromagnet 2 4 electromagnet 2 ca Vca 21 The following sections co...

Page 22: ...via relay normally open contact NO or normally closed contact NC Connect the outputs according to the image below 6 5 1 2 Electromagnets Electromagnets are activated for blocking the turnstile Opposi...

Page 23: ...signal two short rings is not cleared and is forced during 1 second 1 second rings is stuck mid turn for over 2 seconds 1 second rings Connect the outputs according to the following image 6 5 1 4 Conn...

Page 24: ...inputs relay or pushbutton contact normally open and without input voltage enabling passage in face of these signals or NC inputs relay or pushbutton contact usually closed and with input voltage ena...

Page 25: ...The switch or dipswitch DS2 allows programming the following actions invitation turning speed passage counting To program DS2 put each pin in the desired position according to the table below CHAVE 1...

Page 26: ...t with 2 relays Enabling both ways Clockwise and Counter Clockwise with 1 single relay 7654321 U U U U U U U U U U Dry contact Enabling Clockwise Enabling Counter Clockwise 7654321 U U U U U Relay Int...

Page 27: ...Vdc Vdc Vdc 5 24V Integrator s controller board Anti panic drop arm mechanism input Enabling through solid state 10987 U U U U U Integrator s controller 27 Dry contact INFORMATION CCW Counter Clockwis...

Page 28: ...bling through solid state negative Activating through solid state anti panic Drop arm mechanism 1098 Vdc Vdc 5 24V Anti panic 28 54321 Vdc Vdc 5 24V CCW CW Integrator s controller Integrator s control...

Page 29: ...tive Passage confirmation Vcc Rel logic lever SH in disk emulation DIP Ds2 n 7 in mode ON Vdc 4321 Digital positive input U U U U U NA NF Rl2 3 4 NO NC 1 2 Rl1 U U U U U CW CCW 29 98 Vdc 5 24V Vdc Int...

Page 30: ...e pulse Passage confirmation through disk emulation can be set through dip switch Ds2 n 7 in case it s on it ll emulate disk On the other hand it s off it ll general pulse Passage confirmation negativ...

Page 31: ...Electromechanical counter connections 87 Counter Vdc protection diode In case you use inductive counter it will be necessary a protection diode Inductive counter Depends on the couter tension 31...

Page 32: ...rm raised during normal operation In case of power outage when the installation has no no break or through a command sent via system or the activation of an emergency button in the control room the el...

Page 33: ...hnician or a qualified company Each inspection should carry out the following operational sequence for each of the three arms set the arm on the horizontal position turn the turnstile off check if the...

Page 34: ...ress the electromagnet against the lock s frame so that its area is completely against the electromagnet 3 refasten the screws Set of locks Periodicity every 700 00 cycles 0 To check for the need of c...

Page 35: ...he locking device is maladjusted Adjust the electromagnet or forward the equipment to the Technical Assistance The arm does not remain in the correct position There is wear dirt a broken spring or lac...

Page 36: ...Technical characteristics 104 40 40 40 540 71 420 395 155 700 40 40 340 40 930 1262 231 800 40 40 571 40 40 340 358 5 1010 5 INFORMATION he arm clip s size can be altered according to the client s T n...

Page 37: ...Approx 100 kg package included Distance between arms 120 degrees Electromagnets power 12Vcc 2A Power supply Input 100 Vac to 240 Vac 60HZ Output 24 0 Vdc 5 4 5 A Operational temperature from 0 C to 5...

Page 38: ...or technical assistance 3 Warranty shall be granted to the buyer only in the face of the bill of sale original or copy 4 Warranty does not apply in the following cases or conditions a defects and dam...

Page 39: ......

Page 40: ...ustrial Gravata RS CEP 94045 420 Phone 0xx51 3489 8700 3489 8745 Technical assistance 0xx51 3489 8903 Fax 0xx51 3489 1026 Email vendas acesso digicon com br Branch office SP Street S o Paulo 82 Alphav...

Reviews: