Description
3.7
&Q
OPERATING MODE SELECTION
&Q0
Asyncronous direct mode
&Q5
Operation with error correction. It is automatically selected with \N command (different fron 0 and 1)
&Q6
Asynchronous with buffer enabled (AT/N0)
Default=&Q5
&S
C107 (DATA SET READY OPTION)
&S0
DSR will remain ON all the times.
&S1
DSR will became active after answer tone has been detected and inactive after the carrier has been
lost.
Default=&S0
&T
TEST AND DIAGNOSTIC (LOOP)
To use AT&Tn commands the modem must be without error correction (AT\N0).
&T0
Terminate test in progress.
&T1
Local analog loopback.
&T3
Local digital loopback.
&T4
Grant Remote digital loopback test request by remote modem.
&T5
Deny Remote digital loopback test request by remote modem.
&T6
Remote digital loopback.
&T7
Remote digital loopback with self-test.
&T8
Local analog loopback with self-test.
Default=&T4
&V
VIEW ACTIVE PROFILES
&V0
Display the parameters of active profile
&V1
Display the data of active profile
&W
STORE ACTIVE PROFILE
&W0
Store active profile as Profile 0.
&W1
Store active profile as Profile 1.
&Y
DEFINE DEFAULT PROFILE AFTER POWER ON
&Y0
Use profile 0 after power on.
&Y1
Use profile 1 after power on.
Default=&Y0
&Z
STORE THE X TELEPHONE NUMBER IN A N LOCATION
AT&Zn =X (n = from 0 to 3; X = dialing string from 0 to 35 numbers).
&Z
STORE CALLER IDENTIFICATION NUMBER (CALLER ID)
This command enables the storing of a telephone number for the CALLER ID function.
&Z4=nnnn
where nnnn is the telephone number without prefix
&Z4?
show the stored telephone number
To enable the CALLER ID function, please also make reference to the AT*I command.
Store: yes
Default= n/a
SNM7003.pm6
4/8/98, 14:46
7