Digicom SNM70 User Manual Download Page 12

Description

3.3

S

READ/WRITE A REGISTER

Sn=x

Write value x to S Register n.

Sn?

Read value at S Register n.

V

VERBOS RESULT CODE

V0

Result code display as digit (short form).

V1

Result code display as words (extention form).

RESULT CODE SHORT & EXTENDED FORM SUMMARY

SHORT

EXTENDED

0

OK

1

CONNECT

2

RING

3

NO CARRIER

4

ERROR

5

CONNECT 1200

6

NO DIALTONE

7

BUSY

8

NO ANSWER

10

CONNECT 2400

11

CONNECT 4800

12

CONNECT 9600

13

CONNECT 7200

14

CONNECT 12000

15

CONNECT 14400

16

CONNECT 19200

17

CONNECT 38400

19

CONNECT 115200

22

CONNECT 1200TX/75RX

23

CONNECT 75TX/1200RX

40

CARRIER 300

44

CARRIER 1200/75

45

CARRIER 75/1200

46

CARRIER 1200

47

CARRIER 2400

48

CARRIER 4800

49

CARRIER 7200

50

CARRIER 9600

51

CARRIER 12000

52

CARRIER 14400

53

CARRIER 16800

54

CARRIER 19200

55

CARRIER 21600

56

CARRIER 24000

57

CARRIER 26400

58

CARRIER 28800

78

CARRIER 31200

79

CARRIER 33600

66

COMPRESSION: CLASS 5

67

COMPRESSION: V42 bis

69

COMPRESSION: NONE

76

PROTOCOL: NONE

77

PROTOCOL: LAPM

80

PROTOCOL: ALT

150

CARRIER 32000

151

CARRIER 34000

152

CARRIER 36000

153

CARRIER 38000

154

CARRIER 40000

155

CARRIER  42000

156

CARRIER 44000

157

CARRIER 46000

158

CARRIER 48000

159

CARRIER 50000

160

CARRIER 52000

161

CARRIER 54000

162

CARRIER 56000

165

CARRIER 32000

166

CARRIER 34000

167

CARRIER 36000

168

CARRIER 38000

169

CARRIER 40000

170

CARRIER 42000

171

CARRIER 44000

172

CARRIER 46000

173

CARRIER 48000

174

CARRIER 50000

175

CARRIER 52000

176

CARRIER 54000

177

CARRIER 56000

Note: The commands in the above list

can be followed by \ARQ message

SHORT

EXTENDED

SNM7003.pm6

4/8/98, 14:46

3

Summary of Contents for SNM70

Page 1: ...SNM70 Central Site Modem USER S MANUAL Cod 7D1114 rev 1 0 02 98 SNM70CP pm6 4 8 98 14 46 1...

Page 2: ...http www digicom it SNM70CP pm6 4 8 98 14 46 2...

Page 3: ...ODEM AT COMMAND SET 3 1 3 1 1 AT COMMAND SET DESCRIPTION 3 1 3 2 S REGISTERS 3 11 3 2 1 S REGISTER DESCRIPTION 3 12 3 3 FACTORY CONFIGURATIONS 3 15 3 3 1 MODEM FACTORY CONFIGURATION 3 15 4 DIAGNOSTIC...

Page 4: ...problems l Objects which produce a strong electtromagnetic field loudspeakers etc l Liquids or chemical corrosive substances GENERAL WARNINGS for all equipment powered directly from mains power POWER...

Page 5: ...THE TERMINAL Use a clean and soft cloth Wet the cloth with water or natural detergent if it is necessary to remove any stains Never use chemical products such as petrol or solvents VIBRATIONS OR DROPP...

Page 6: ...neous incoming connections at 56K To realise the 56K connection speed the remote user client must have a K56Flex standard modem and simply dials one of the two telephone numbers to connect to the host...

Page 7: ...present on the Floppy Disk or the CD ROM included with the modem package In this file you can read more details about the driver installation for the different versions of Windows 95 and also the late...

Page 8: ...t connection 2 3 FRONT PANEL On the front panel are present LED that indicate the most important interface circuit in use In the following table is present the complete description and function of eac...

Page 9: ...3 1 SNM 70 Front view 2 4 REAR PANEL On the rear panel is the power switch the two V24 interface connectors and the RJ45 ISDN network connector JC RS232 V 24 V 28 female serial interface connector of...

Page 10: ...Off Line or in a idle condition In this mode the modem will accept commands beginning withAT prefix Data mode is when the modem is connected to another modem that is an On Line condition or functioni...

Page 11: ...CTION H0 Modem disconnects H1 Modem connects to the line and remain in command mode for the time defined in S7 I IDENTIFICATION I0 Maximum line speed I1 Product type I2 Checksum firmware I3 Product na...

Page 12: ...CARRIER 9600 51 CARRIER 12000 52 CARRIER 14400 53 CARRIER 16800 54 CARRIER 19200 55 CARRIER 21600 56 CARRIER 24000 57 CARRIER 26400 58 CARRIER 28800 78 CARRIER 31200 79 CARRIER 33600 66 COMPRESSION C...

Page 13: ...connect Innon errorcorrectionmodeorinbuffermode themodemwillsend a long space of four seconds prior to going on hook In error correction mode the modem will send respond to the receipt of a long space...

Page 14: ...Trasmission rate at 56000 AT MS 56 1 300 33600 1 0 56000 l Modem set up in V 34 with automode disabled and speed fixed at 33 600 bps AT MS 56 1 300 33600 1 0 33600 In this case the modem makes the con...

Page 15: ...F for 1 sec function 109 wink C1 Carrier detect is ON when remote carrier is present Default C1 D DATA TERMINAL READY OPTION D0 DTR signal is ignored D1 Modem return to Command Mode upon detecting ON...

Page 16: ...6 Remote digital loopback T7 Remote digital loopback with self test T8 Local analog loopback with self test Default T4 V VIEW ACTIVE PROFILES V0 Display the parameters of active profile V1 Display the...

Page 17: ...to define the kind of TEI automatic or fixed AT Z7 from 00 to 63 Gives and stores a specific TEI fixed TEI AT Z7 automatic TEI A MNP BLOCK SIZE A0 Block size 64 chr A1 Block size 128 chr A2 Block siz...

Page 18: ...and sends break to the Computer K1 Same as 0 K2 Send a break immediately to Computer K3 Same as 2 K4 Send a break in sequence with received data to Computer K5 Same as 4 Default K5 N ERROR CORRECTION...

Page 19: ...alled party number with the number stored in its memory with the AT Z5 command if the two numbers matched then it answers the call otherwise it does not In order for this feature to work the receiver...

Page 20: ...on about its configuration All values are in decimal format If the register type is non storable the register value has to be written after SNM 70 reset or powered on REG RANGE UNIT DEF DESCRIPTION S0...

Page 21: ...CII It contains the character recognized by the modem for the ESCAPE sequence If value is higher than 127 the ESCAPE sequence is disabled Default 43 Type storable S3 CARRIAGE RETURN CHARACTER Value Un...

Page 22: ...nit Function 0 255 20msec Guard time for Escape Default 50 Type storable S18 TEST TIMER Value Unit Function 0 255 1msec Test Timer Default 0 Type storable S30 INACTIVITY DISCONNECT TIMER Value Unit Fu...

Page 23: ...ble S95 ATW0 ATW1 ATW2 0 CONNECT Computer PROTOCOL Prot CONNECT Dce CONNECT Computer 0 CONNECT Computer PROTOCOL Prot CONNECT Dce CONNECT Computer 1 CONNECT Dce PROTOCOL Prot CONNECT Dce CONNECT Dce 2...

Page 24: ...tched AT K3 Hardware flow control AT N3 Error correction enabled AT C3 Data compression enabled ATW2 Extended result code AT MS 56 1 300 33600 1 0 56000 CONFIGURATION N 1 loadable with AT F1 This conf...

Page 25: ...set up without error correction AT N0 4 2 1 LOCAL ANALOG LOOPBACK TEST CCITT LOOP 3 Scope of this test is to verify the modem itself When the modem is Off Line type the command AT T1 This command for...

Page 26: ...modem in digital loop mode simulating the connection of digital send data and receive data before reaching the remote computer You can send single characters character strings or files and they are re...

Page 27: ...rmity with the technical characteristics described in the users manual supplied with the equipment WARRANTY WARRANTY CLAUSES l The equipment has a warranty which covers manufacturing and operating fau...

Reviews: