7.6
PALLADIO ISDN
AT Command Set
&K
Flow control
Define the flow control options
&K0
NO flow control.
&K3
Hardware RTS/CTS flow control
&K4
Bi-directional software XON/XOFF (ISDN modem —>
Computer and Computer —> ISDN modem) flow control. The
ISDN modem doesn’t transmit to the remote the XON/XOFF
chars received from the Computer.
&K8
Unidirectional software XON/XOFF (ISDN modem —>
Computer) flow control. The ISDN modem doesn’t recognize
the XON/XOFF chars received from the Computer
&K12
Bi-directional software XON/XOFF (ISDN modem —>
Computer and Computer —> ISDN modem) flow control. The
ISDN modem transmit to the remote the XON/XOFF chars
received from the Computer.
&K16
Software XON/XOFF ISDN modem <—> ISDN modem flow
control. (V.110 only). In this mode there is flow control between
local and remote ISDN modem.There is no flow control on the
Computer interface.
&K20
Software XON/XOFF Computer <—> ISDN modem and ISDN
modem <—> ISDN modem flow control. (V.110 only).
Default= &K3
&S
C107 (DSR) control
Establish how the C107 (DSR) will operate.
&S0
C107 (DSR) is always ON.
&S1
C107 (DSR) function as standard; DSR is ON when the
connection is established and will be OFF when ISDN modem
hangs-up.
Default=&S0
&T
Enable or disable Loop test
Allow to select the of loop test.
&T0
Terminates test modes
&T1
Enable local loopback (loop 3).
&T3
Enable on the B1 channel the local digital loopback (V.110 only).
To activate this test, follow these steps:
- Make a connection with a remote ISDN modem
- Go in Escape mode with “+++” command
- Send the AT&T3 loop test
- All the data trasmitted from the remote ISDN modem, are
resended on the line to the local ISDN modem
Default= n/a
Summary of Contents for PALLADIO ISDN
Page 1: ...http www digicom it User s Guide rev 1 0 del 04 2002 PALLADIO ISDN...
Page 2: ......
Page 6: ......
Page 12: ......
Page 27: ...PALLADIO ISDN Driver Installation Windows 2000 4 7...
Page 34: ......
Page 56: ......
Page 58: ......
Page 62: ...10 4 PALLADIO ISDN RVS COM Lite Installation Select Digicom PALLADIO and serial port eg COM3...
Page 65: ...ITALY 21010 Cardano al Campo VA via A Volta 39...