Operate in API mode
API frames
XBee/XBee-PRO DigiMesh 2.4 RF Module User Guide
141
Frame data
fields
Offset Description
Digi
Manufacturer
ID
33-34
Set to the Digi Manufacturer ID.
Digi DD value
(optional)
35-38
Reports the
DD
value of the responding device. Use the
NO
command to
enable this field.
RSSI (optional)
39
Received signal strength indicator. Use the
NO
command to enable this
field.
Example
If you press the commissioning pushbutton on a remote device with 64-bit address
0x0013A200407402AC and a default
NI
string sends a Node Identification, all devices on the network
receive the following node identification indicator:
A remote device with 64-bit address 0x0013A200407402AC and a default
NI
string sends a Node
Identification, all devices on the network receive the following node identification indicator:
0x7e 0025 9500 13a2 0040 7402 acff fec2 fffe 0013 a200 4074 02ac 2000 fffe 0101
c105 101e
If you press the commissioning button on a remote router device with 64-bit address 0x0013A200
40522BAA, 16-bit address 0x7D84, and default
NI
string, devices on the network receive the node
identification indicator.
Frame data fields
Offset
Example
Start delimiter
0
0x7E
Length
MSB 1
0x00
LSB 2
0x25
Frame type
3
0x95
64-bit source address
MSB 4
0x00
5
0x13
6
0xA2
7
0x00
8
0x40
9
0x74
10
0x02
LSB 11
0xAC
Reserved
12
0xFF
13
0xFE