Operate in API mode
API frames
XBee/XBee-PRO DigiMesh 2.4 RF Module User Guide
124
Frame data fields
Offset
Example
Start delimiter
0
0x7E
Length
MSB 1
0x00
LSB 2
0x10
Frame type
3
0x17
Frame ID
4
0x01
64-bit destination address
MSB 5
0x00
6
0x13
7
0xA2
8
0x00
9
0x40
10
0x40
11
0x11
LSB 12
0x22
Reserved
13
0xFF
14
0xFE
Remote command options
15
0x02 (apply changes)
AT command
16
0x42 (B)
17
0x48 (H)
Command parameter
18
0x01
Checksum
19
0xF5