![Digi SM-500MK4 Service Manual Download Page 89](http://html.mh-extra.com/html/digi/sm-500mk4/sm-500mk4_service-manual_2496550089.webp)
SM500MK4 Service Manual
86
SPEC 632: SELECTION OF TARE VALUE EXCHANGE
0: ALLOW
1: INHIBIT
SPEC 633: SELECTION OF AUTO CLEAR OF TARE
0: INHIBIT
1: ALLOW
SPEC 634: SELECTION OF AUTO TARE CLEARS WHEN REZERO
0: INHIBIT
1: ALLOW
SPEC 635: SELECTION OF TRIGGER POINT OF TARE / UNIT PRICE AUTO CLEAR
0: OVER NET 5d & OVER GROSS 21d & WEIGHT STABILITY
1: > = NET 1d AND WEIGHT STABILITY
2: > = NET 1d AND PRICE > 0 AND WEIGHT STABILITY
SPEC 636: SELECTION OF AUTOMATIC ZERO RESET
0: INHIBIT
1: ALLOW
SPEC 637: SELECTION OF NEGATIVE WEIGHT TARE CLEAR
0: ALLOW
1: INHIBIT
SPEC 638: SELECTION OF TARE RANGE
0: LESS THAN 50 % OF CAPACITY
1: LESS THAN 5 % OF CAPACITY
3: MAX 200G
2: NOT USED
SPEC 639: SELECTION OF EXIT FROM ACCUMULATION MODE WHEN WEIGHT CHANGE
0: INHIBIT
1: ALLOW
SPEC 640: SELECTION OF PRICE ACCUMULATION WITH WEIGHT CHANGE > ± 10d
0: INHIBIT
1: ALLOW
SPEC 641: ACCUMULATION AVAILABLE ONLY AFTER SCALE SHOWS WEIGHT = ' 0 '
0: INHIBIT
1: ALLOW
SPEC 642: SELECTION OF TARE DISPLAY FOR ONE-TOUCH-TARE
0: ALLOW
1: INHIBIT
SPEC 643: SELECTION OF WEIGHT RANGE OF NON - WEIGH ITEMS
0: ONLY NET 0d
1: UNDER NET 0d
2: UNDER NET 4d
3: GROSS < 1d
4: ALWAYS
SPEC 644: SELECTION OF WEIGHT STABILITY CONDITION
0: LOOSE
1: NORMAL
2: TIGHT
3: STRINGENT
SPEC 645: SELECTION OF WEIGHT RANGE FOR REGISTRATION MODE PRINTING
0: OVER NET 5d & OVER GROSS 21d & WEIGHT STABILITY
1: OVER NET 1d AND WEIGHT STABILITY
2: OVER NET 19d AND WEIGHT STABILITY
3: OVER NET 20d AND WEIGHT STABILITY
All manuals and user guides at all-guides.com