background image

SM 110                                                                                                      PROGRAM MODE 

67 

3.16.7 Sample of program a format by modifying the existing format 

You can create your desired label format by copying an existing format and modifying it to your needs.   

 

 
 

 
 
 

All manuals and user guides at all-guides.com

Summary of Contents for SM-110

Page 1: ...____ SHANGHAI TERAOKA ELECTRONIC CO LTD TECHNICAL SUPPORT DEPARTMENT 3rd Floor of 2nd Building Jia Yuan Business Center 51 Long Wu Road Shanghai China 200232 TEL 86 21 6408 5151 FAX 86 21 6408 3468 EMAIL ADDRESS steservice digi scale com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...Notice Welcome to use DIGI s product Please see the operation manual and learn how to use our products Thank you All manuals and user guides at all guides com ...

Page 3: ... 12 2 1 Setup 12 2 2 Location of Switches and Connectors 14 2 3 Mode Change 14 2 4 Memory Initialization 15 2 5 Specification Setting 15 2 6 Password Setting 16 2 6 1 Procedures of Password Setting 16 2 6 2 Password Using 16 2 7 Clear Files 17 3 PROGRAM MODE 18 3 1 Programmable Files 18 3 2 General Explanation 19 3 3 Department Files 20 3 3 1 Program Department File 20 3 3 2 Delete Department File...

Page 4: ... 3 8 2 Function Key Assignment 42 3 8 3 Delete Preset Key Assignment 43 3 9 Shop Name File 44 3 9 1 Program Shop Name File 44 3 9 2 Delete Shop Name File 45 3 10 Advertisement File 46 3 10 1 Program Advertisement File 46 3 10 2 Delete Advertisement File 47 3 11 Vender File 48 3 12 Program Date And Time 49 3 13 Special Message File 50 3 13 1 Program Special Message File 50 3 13 2 Delete Special Mes...

Page 5: ...chine Setting 71 3 19 Logo File 72 3 19 1 Pre programming Logo Data 72 3 19 2 Program Display Keys Function 73 3 19 3 Programming Order 74 3 19 4 Program Logo File 74 3 19 5 Delete Logo File 75 3 20 Tax File 76 3 20 1 Program Tax File 76 3 20 2 Delete Tax File 77 3 21 Scroll Message File 78 3 21 1 Program Scroll Message File 78 3 21 2 Delete Scroll Message File 78 3 22 Scroll Sequence File 79 3 22...

Page 6: ...7 4 6 Operation Mode Change 88 4 7 Item Label Printing in Manual Mode 89 4 7 1 Label Printing for PLU Item 89 4 7 2 Label Printing for NON PLU Item 90 4 8 Total Label Printing in Manual Mode 91 4 8 1 Sales Transaction 91 4 8 2 PRICE DISCOUNT Function Key in Add Mode 92 4 8 3 PRICE DISCOUNT Function Key in Add Mode 92 4 9 Data Correction 93 4 9 1 On The Spot Correction 93 4 9 2 Void by Item Correct...

Page 7: ...t 101 5 2 5 24Hour Report 101 5 2 6 ABC Report 101 5 2 7 Clerk Report 102 5 2 8 Pre pack Report 103 5 2 9 Tax Report 104 5 2 10 Store Summarized Report 104 6 RESET REPORT MODE 105 7 Apendix 106 A Specification List B Flexible Barcode Setting Guide C Traceability Setting Guide D Nutrition Setting Guide E Operational Menu Tree All manuals and user guides at all guides com ...

Page 8: ...SM 110 GENERAL 1 1 GENERAL 1 1 Overall View z Bench Type z Pole Type All manuals and user guides at all guides com ...

Page 9: ...10 GENERAL 2 1 2 Display Panel z 25 digits 19 segments TN type LCD z 32 202 full dot Martix Green LCD 1 3 Key Panel z 32 Preset Keys Type z 56 Preset Keys Type All manuals and user guides at all guides com ...

Page 10: ...est print in S Mode CLEAR KEY C For Back space or Clear numeric value Select YES in S and Z Mode RE ZERO KEY Reset weight to ZERO PREPACK KEY AUTO Switch Manual mode and Pre pack mode alternatively The mode status will be indicated in the P and M indicator P PRE PACK MODE M MANUAL MODE CHANGE KEY Calculate the Changed Amount Escape the Programming screen without saving data in S Mode All manuals a...

Page 11: ...rt Type in X Mode Select Data Transaction Type in Z Mode CLERK KEY V1 V4 Accumulate the Total Price VOID KEY Correct the sales data PLU KEY PLU Call up PLU data in R Mode Store the programmed data in S Mode FEED KEY Feed Label or Receipt paper PRINT KEY Print out Label or Receipt All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 12: ... preset data such as products data shop name etc Indicator Z TOTAL MODE Clear sales data stored Indicator X Blink Password Setting Mode Set PASS WORD for X S Z mode set PASSWORD for PASSWORD MODE when all indicators R X S Z blink Decrease Increase Specification Count key Decrease Increase Only used when Setting SPEC 141 142 Select parameter data such as SPEC data Move cursor left or right All manu...

Page 13: ...K LHE4253SU z Max Printing With 56mm z Compare of Two Thermal Head Types of SM Series Scales SM 100 SM 80L SM 300 SM 80 SM 500 Thermal Head Model TDK LHE4253SU TDK LH 3139K Max Printing Width 56mm 60mm Thermal Head Photo All manuals and user guides at all guides com ...

Page 14: ...perator display optional customer pole display y 25 digits x 19 segments TN type LCD with back light for numeric digit and character display 32 x 202 full dot Martix Green LCD display y 55 83 membrane keys a ON OFF key b 10 Numeric keys to key in numeric data c 32 56 Preset keys to preset PLU or function into the key d 23 27 Operational keys to perform various functional operations y 18 data files...

Page 15: ...rtix Green LCD display y Tare weight display 4 digits y Weight display 5 digits y Unit price display 6 digits y Total price display 7 digits 1 6 2 Operating Conditions z Power Source AC 176V 264V 47 63Hz z Operating Temperature 10 C 40 C z Operating Humidity 15 85 RH z Power Consumption 0 15A 1 6 3 Dimensions z Platter size 359 W x 277 D mm z Overall size a Bench 383 4 W x 389 3 D x 162 H mm b Pol...

Page 16: ... wound wrongly printing problem may result We do not recommend the use of varnish labels Label Type Dimension mm T1 28 X 56 T2 31 X 56 T3 34 X 56 T4 40 X 56 T5 43 X 56 T6 46 X 56 T7 49 X 56 T8 55 X 56 T9 37 X 56 T10 40 X 56 T11 43 X 56 T12 49 X 56 S 28 X 37 A 46 X 37 B 46 X 37 C 62 X 37 F1 F99 Free Format All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 17: ...SM 110 INITIAL SETUP 12 2 INITIAL SETUP 2 1 Setup Indication of Assemble 1 Use 4 screws to fix the Pole 1 Use 1 flat screws to fix the Pole All manuals and user guides at all guides com ...

Page 18: ...NITIAL SETUP 13 Bubble Adjustment Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the centre as shown above Bubble All manuals and user guides at all guides com ...

Page 19: ...p S turns on MODE Z1 0 RESET SALES DAILY Enter Z mode Lamp Z turns on MODE PWD X 0 SET Enter Password Set mode Lamp X flicker MODE 0 000 0 000 0 00 0 00 Back to Weight mode Lamp R turns on 2 4 Memory Initialization To clear all memory DISPLAY OPERATION PT kg kg REMARK Z1 0 RESET SALES DAILY Z mode Lamp Z turns on DISPLAY OPERATION PT kg kg REMARK Power Switch Cash Drawer Port RS232 Port Ethernet P...

Page 20: ...depressing Rezero XXX SPEC data SPEC 001 XXX XXX key only increase specification count it does not update SPEC data SPEC 000 XXX XXX key only decrease specification count it does not update SPEC data 1 7 X SPEC 000 SPEC 017 017 XXX XXX XXX It goes to a designed specification count 000 441 is enabled SPEC 017 XXX XXX key select SPEC data Move cursor right SPEC 017 XXX XXX key select SPEC data Move ...

Page 21: ...password for Z mode Lamp Z flicker 3 3 C PWD Z PWD Z 33 0 SET SET Clear the password for Z mode PWD P XXXX SET Display password for PWD mode Lamp R X S Z flicker 1 1 1 1 PWD P 1111 SET Set password for PWD mode as 1111 Lamp R X S Z flicker 0 000 0 000 0 00 0 00 Return R mode after password setting 2 6 2 Password Using Hypothesis PWD X 1111 PWD S No Set PWD P 1234 DISPLAY OPERATION PT kg kg REMARK ...

Page 22: ...ord 1 2 3 4 ENTER PWD X PWD P 1111 SET Correct password Enters PWD mode MODE 0 000 0 000 0 00 0 00 Back to Weight mode Lamp R turns on 2 7 Clear Files This function is used to clear files in Memory DISPLAY OPERATION PT kg kg REMARK Z1 0 RESET SALES DAILY Z mode Lamp Z turns on Rezero 2 3 0 CLEAR PLU FILE PLU file CLEAR VENDER DATA Vender transaction data CLEAR REPORT FILES Report files CLEAR MEMOR...

Page 23: ...mming 1 7 Logo Programming 2 Department Programming 1 8 Tax Programming 3 Main Group Programming 1 9 Program or Skip Item Data 4 Key Assignment 2 0 Memory Status 5 Shop Name Programming 2 1 I F Test 6 Advertisement Programming 2 2 File Load 7 Vender Programming 8 Date and Time Programming 9 Special Message Programming 1 0 Ingredients Programming 1 1 Text Programming 1 2 Free Format Programming 1 3...

Page 24: ...category including items such as BEEF PORK CHICKEN etc You can link a Main Group to a Department in the Main Group file Tax Number can be assigned to a Main Group The assigned Tax Number will apply for all the PLU s assigned to the Main Group PLU FILE PLU File is the smallest category including items such as BEEF SLICE BEEF SHOULDER and BEEF SIRLOIN You can link the PLU to a Main Group in the PLU ...

Page 25: ...2 1 DEPT NAME 0 Enter department programming set the department name M E A T S2 1 DEPT MEAT NAME 4 Enter DEPT name use letter keys Ex MEAT for Dept No 1 The methods of ASII letter input refer to 3 23 ASSII Character Input Method PLU S2 DEPT FILE Store the department file back to S mode Note1 Number after NAME in Total display shows the position of the cursor Note2 The DEPT No 1 to No 99 are availa...

Page 26: ...dicates DEPT code 1 S2 0 DEPT 1 NO SET Enter department No Ex 1 Delete Dept No 1 for MEAT S2 0 DEPT DEL Y C N T C for Yes T for No C S2 DEPT FILE Delete the Dept file 1 back to S mode Note1 When the MAIN GROUP FILE exists under the Department File the Department Number cannot be deleted In addition the Department Number 97 98 and 99 cannot be deleted All manuals and user guides at all guides com a...

Page 27: ... S3 0 MG 0 NO SET kg window indicates Main Group code 1 1 1 S3 0 MG 111 NO SET Select Main Group No Ex 1 1 1 S3 1 MG 97 default DEPT NO Enter Main Group programming Set the Department number 1 S3 1 S3 2 MG MG 1 DEPT NO NAME 0 Link Main Group 111 to Department 1 B E E F S3 2 S3 3 MG MG BEEF 0 NAME 4 TAX NO Name of the Main Group 111 is BEEF Set the Tax number 1 S3 3 MG 1 TAX NO Tax of Main Group 11...

Page 28: ...linked to the exiting Dept No Refer to 3 3 Department File 3 4 2 Delete Main Group File DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 3 or S3 S3 0 MG MGROUP 0 FILE NO SET Select Main Group Programming and Enter it 1 1 1 S3 0 MG 111 NO SET Enter Main Group No Ex 1 1 1 S3 0 MG DEL Y C N T C for Yes T for No C S3 MGROUP FILE Delete M G file 111 back to S mo...

Page 29: ...PACKDT 11 PACKTM 11 Packed Time PACKTM 12 COST 12 Cost COST 13 TARE 13 Tare TARE 14 QTY 14 Quantity QTY 15 Q UNIT 15 Quantity Unit QUNIT 16 DISCNT 16 Discount Status DISCNT 17 SCH DT 17 Discount Schedule date SCHDT 18 SCH TM 18 Discount Schedule time SCHTM 19 MARKDN 19 Mark Down Status MARKDN 20 1STLMT 20 1st target for discount 1 FSTLMT 21 2NDLMT 21 2nd target for discount 2 SNDLMT 22 SMGNUM 22 S...

Page 30: ...U PRIC 50 Unit Price Selection UPRIC 51 PLUSCR 51 PLU Scroll U1 only PLUSCR 52 PLUTEX 52 PLU Linked Text Field PLUTEX Program Skip Item Data DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 1 9 or S19 PLU ITEM Select PLU item Selection Mode and enter S19 1 ITEM LABFR1 PROGRAM Enter Program or Skip parameter selection mode S19 1 ITEM MGCODE SKIP Select param...

Page 31: ...cted in the barcode type selection in S1 6 S1 9 Item Code No Lower 4 digits Only when Item Code is more than 6 digits S1 10 Right Side Data of Item Barcode Only when Spec02 set to 3 S1 11 Selection of EAN ADD ON S1 12 Main Group No S1 13 Select whether to print Sell by date S1 14 Sell by date Days after the current date If No Print is selected Sell by Date in S1 12 is skipped S1 15 Select whether ...

Page 32: ...olume Discount The start date S1 36 Schedule of Volume Discount The start time S1 37 Schedule of Volume Discount The end date S1 38 Schedule of Volume Discount The end time S1 39 Selection of Discount Day of The Week S1 40 Special message No Select No from SP message file S1 41 Ingredient No Select No from Ingredient file S1 42 Special message Program original Special Message S1 43 Ingredient Prog...

Page 33: ... Select whether to print Sell by time If No Print is selected Key in selection in S1 14 Sell by time in S1 15 is skipped S1 16 Select key in data or present time S1 17 Sell by Time If Key In is selected If S1 14 select CLOCK TIME Key in selection in S1 15 is skipped S1 18 Select whether to print Used by date S1 19 Used by date days after Packed date If No Print is selected Used by Date in S1 17 is...

Page 34: ...ount The end date S1 38 Schedule of Volume Discount The end time S1 39 Selection of Discount Day of The Week S1 40 Special message No Select No from SP message file S1 41 Ingredient No Select No from Ingredient file S1 42 Special message Program original Special Message S1 43 Ingredient Program original Ingredient If selected Label Format without PRINT AREA S1 40 S1 43 are skipped S1 44 Place of p...

Page 35: ...FT 0 LAB FR1 Select Label format for 1st Label by press or key T1 T12 S A B C F1 F8 is available or S1 2 PLU T6 6 LAB FR1 Set the Label format Ex T6 by press 6 or key S1 3 PLU NO 0 LAB FR2 Select Label format for 2nd Label by press or key F1 F8 only or S1 4 C01 01 S1 A 100 Enter commodity name Ex SLICE S L I C E S1 4 C02 01 S1 A 100 Enter the 2nd line of commodity name S1 5 PLU EAN BARCODE Select ...

Page 36: ...ll by time S1 18 PLU NPRINT USED DT Press or key to change whether print used by date Ex No print used by date Set used by date used by time Setting way of used by date used by time are same as setting sell by date and sell by time S1 20 PLU NPRINT PACK DT Press or key to change whether print packed date or S1 21 PLU 0 PACK DT If necessarily packed date can set the day after present date Ex 1 day ...

Page 37: ... YY 1 0 0 1 0 4 S1 36 PLU 0000 ST TIME Set discount start time Ex 09 00 HH MM 0 9 0 0 S1 37 PLU 000000 ED DATE Set discount end date Ex 11 01 04 1 1 0 1 0 4 S1 38 PLU 0000 ED TIME Set discount end time Ex 09 00 0 9 0 0 S1 40 PLU 0 SMG NUM Set special message file number Ex Number 1 Special message file 1 is linked to this PLU 1 S1 41 PLU 0 ING NUM Set ingredients file number Ex Number 1 Ingredient...

Page 38: ...ot have print area for the PLU items the item will be skipped automatically or not printed on label DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on S1 0 PLU 0 NO SET Enter PLU programming mode kg window displays PLU number 2 0 0 S1 0 PLU 200 NO SET Enter new PLU Number Ex 200 you want S1 1 PLU 0 00 PR KG Enter PLU programming Enter unit price Ex 5 80 kg or...

Page 39: ...pended item code of PLU 100 S1 10 PLU EAN ADD OFF Select EAN ADD ON or EAN ADD OFF Ex EAN ADD OFF S1 12 PLU 997 MG NO Set the Main Group number default MG 997 Enter Main Group No Ex 222 Link PLU 200 to Main Group 222 2 2 2 S1 13 PLU NPRINT SELL DT Press or key to change whether print sell by date Ex Print sell by date or S1 14 PLU 0 SELL DT Set sell by date Ex 3 days 3 digits can be set 0 999 3 S1...

Page 40: ...0 1 8 0 0 S1 25 PLU 0 00 COST S1 27 PLU PCS USYMBOL Press or to select unit symbol Selection PCS FOR kg lb g NO or S1 28 PLU 0 QTY 4 digits can be set 0 9999 Ex 10 pcs PLU 1 0 S1 29 PLU NO DISCONT 6 kinds discount type can be selected by press or key Ex UNIT PRICE discount or S1 34 PLU NO MARK DOWN Change selection by or No mark down Unit price mark down Total price mark down all mark down or S1 3...

Page 41: ...otal Price display shows the letter font size of the commodity name and the number after A in Total Price display shows the number of letters can be programmed for commodity name Note3 The 2 digits after C in Weight display shows the line of the commodity name and the next 2 digits in Weight display shows the position of the cursor Note4 The PLU No 1 to No 999999 are available for PLU programming ...

Page 42: ... 0 NO SET Enter PLU programming mode kg window displays PLU number 1 2 4 S1 1 PLU 124 NO SET Select PLU 124 enter PLU programming X S1 1 PLU 0 COPY Press X key to enter PLU copy function 1 0 0 S1 1 PLU 5 80 PR KG Copy PLU 100 data to PLU 124 4 8 0 S1 2 PLU T6 6 LAB FR1 Unit price of PLU 124 is 4 80 kg S1 3 PLU NO 0 LAB FR2 The 1st Label format is T6 S1 4 C01 01 SLICE S1 A 95 Commodity Name of PLU ...

Page 43: ...isplays PLU number 1 2 4 S1 0 PLU 124 NO SET Select PLU 124 Ex Delete PLU No 124 S1 0 PLU DEL Y C N T Press key to delete PLU 124 C for Yes T for No C S1 PLU FILE Delete PLU file No 124 back to S mode Note1 Only the programmed PLU file can be deleted Note2 In the last operation pressing T key can back to the S Mode without deleting PLU file 124 All manuals and user guides at all guides com ...

Page 44: ... Total Price 0 Unit Price Discount To select Formula 1 or Formula 2 can be decided by SPEC 124 Setting 1 Unit Price Original Unit Price Unit Price discount amount 2 Unit Price Unit Price discount amount Original Unit Price 10 00 Unit Price discount amount 2 00 1 Unit Price 10 00 2 00 8 00 2 Unit Price 2 00 Unit Price Discount Unit Price Original Unit Price x 100 Discount Original Unit Price 10 00 ...

Page 45: ...k down Unit Price Price Mark down Type of Sales price function Description of Sales Price data on label Unit Price Total Price No Mark Down 1 50 15 00 Unit Price Mark Down 2 00 1 50 15 00 Total Price Mark Down 1 50 Refer to Note 1 20 00 15 00 Unit Total Price Mark Down 2 00 1 50 20 00 15 00 Note 1 Since discount unit price cannot be calculated if Total Price discount is used it is not able to use ...

Page 46: ...ammable PLU DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 2 0 S20 MEMORY STATUS Select memory status check mode You can press or key to select this mode S20 0 PLU P 7 LF 4544 T S20 MEMORY STATUS Back to S mode All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 47: ...PRESET 1 S4 0 PS AS 0 NO SET PLU No 100 had been assigned to Preset Key 1 C S4 KEY ASSIGNMENT Back to S mode Note1 Non existing PLU No can not be assigned Note2 If assigning PLU Number 50 to the Preset key No 1 has been already programmed the PLU No 50 will replace the old data of Preset Key No 1 but PLU Number cannot replace the preset key are already assign for Function Key Vender Key or Preset ...

Page 48: ... delete the Preset Key Assignment for PLU preset key Function Key and Vender key DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 4 or three times S4 KEY ASSIGNMENT Key Assignment mode is MENU 4 in S mode S4 0 PS AS 0 NO SET Enter PLU assignment mode S4 2 FN AS 0 CLEAR Enter Function Key assignment status PRESET 25 S4 0 FN AS DEL Y C N T Enter deleting mode...

Page 49: ...C251 3 9 1 Program Shop Name File At Programming Mode select Shop Name programming mode and then enter new Shop Name number Ex 1 programming mode DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 5 or four times S5 SHOP NAME FILE Shop name File mode is MENU 5 in S mode S5 0 SHOP 0 NO SET Enter Shop Name File programming mode 1 S5 1 S01 01 S1 A 100 Enter shop...

Page 50: ...SHOP NAME FILE Shop name File mode is MENU 5 in S mode S5 0 SHOP 0 NO SET Enter Shop Name File programming mode 1 S5 0 SHOP 1 NO SET Enter shop name file 1 Ex No 1 S5 0 SHOP DEL Y C N T Enter deleting mode C for Yes T for No C S5 SHOP NAME FILE Delete Shop Name File 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Shop Name File can not be deleted Al...

Page 51: ...ode select Advertisement programming mode and then enter new Advertisement number Ex 1 programming mode DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 6 or five times S6 ADVER MESSAGE Select advertisement file programming mode S6 0 ADVER 0 NO SET Enter advertisement File programming mode 1 S6 1 A01 01 S1 A 100 Enter the advertisement File No 1 Ex No 1 T H...

Page 52: ...R MESSAGE Select advertisement file programming mode S6 0 ADVER 0 NO SET Enter advertisement File programming mode 1 S6 0 ADVER 1 NO SET Enter advertisement File 1 Ex No 1 S6 0 ADVER DEL Y C N T Enter deleting mode C for Yes T for No C S6 ADVER MESSAGE Delete advertisement File 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Advertisement File can n...

Page 53: ...grammed Vender name can be printed on receipt when SPEC 21 set to NAME DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 7 or six times S7 VENDER FILE Select Vender file programming mode S7 0 CLERK 0 NO SET Enter Vender File programming mode 1 S7 1 CLERK 1 NAME 0 Select vender key Ex V1 Program operator name for Vender 1 M I K E S7 1 CLERK MIKE NAME 4 Enter ...

Page 54: ...ATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 8 or seven times S8 DATE AND TIME Select Date and Time programming mode P8 0 DATE 010100 MMDDYY Enter Date and Time programming mode 0 8 1 9 0 4 P8 1 TIME 0000 HHMM Set Month 08 Day 19 and Year 04 Ex 2004 08 19 9 0 0 S8 DATE AND TIME Set Hour 9 Minute 05 Store Date and Time back to S mode All manuals and user guides at a...

Page 55: ...d Free Format 3 13 1 Program Special Message File At Programming Mode select Special Message programming mode and then enter new Special Message number Ex 1 programming mode For edit enter existing Special Message number DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 9 or eight times S9 SP MESSAGE Select special message file programming mode S9 0 SP MG 0 ...

Page 56: ...ect special message file programming mode S9 0 SP MG 0 NO SET Enter special message File programming mode 1 S9 0 SP MG 1 NO SET Enter special message File 1 Ex No 1 S9 0 SP MG DEL Y C N T Enter deleting mode C for Yes T for No C S9 SP MESSAGE Delete special message File 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Special Message File can not be ...

Page 57: ...ter new Ingredient number Ex 1 programming mode For edit enter existing Ingredient number DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 10 or nine times S10 INGR FILE Select Ingredient file programming mode S10 0 INGR 0 NO SET Enter Ingredient File programming mode 1 S10 1 G01 01 S1 A 100 Enter the Ingredient File No 1 Ex No 1 S U G A R S10 1 G01 06 SUGA...

Page 58: ...10 INGR FILE Select Ingredient file programming mode S10 0 INGR 0 NO SET Enter Ingredient File programming mode 1 S10 0 INGR 1 NO SET Enter Ingredient File 1 Ex No 1 S10 0 INGR DEL Y C N T Enter deleting mode C for Yes T for No C S10 INGR FILE Delete Ingredient File 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Ingredients File can not be deleted ...

Page 59: ...t programming mode and then enter new Text number Ex 1 programming mode For edit enter existing Text number DISPLAY OPERATION PT kg kg REMARK MODE MODE MODE S1 PLU FILE Enter S mode Lamp S turns on 11 or ten times S11 TEXT FILE Select Text file programming mode S11 0 TEXT 0 NO SET Enter Text File programming mode 1 S11 1 T01 01 S1 A 100 Enter the Text File No 1 Ex No 1 P A C K A G E S11 1 T01 08 C...

Page 60: ...imes S11 TEXT FILE Select Text file programming mode S11 0 TEXT 0 NO SET Enter Text File programming mode 1 S11 0 TEXT 1 NO SET Enter Text File 1 Ex No 1 S11 0 TEXT DEL Y C N T Enter deleting mode C for Yes T for No C S11 TEXT FILE Delete Text File 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Text File can not be deleted All manuals and user guid...

Page 61: ...eneral Information Label format within the following height and width can be created Up to 99 Free Formats can be stored in the memory apart from the other 16 standard formats Standard format can be used as a basic format for creating a new format Print position of each item is programmed using mm One Item label or one Total label is available for each Free Format number F1 F99 4 Print Angles can ...

Page 62: ...1mm to the edges of the label The print position of each item is determined by setting the interval from 0 point X 0 Y 0 to the base position of the programmed item X and Y values need to be entered by mm Print Area The item data cannot be printed at the bottom 10 mm of labels Pre print data such as shop name or logo data is programmed at the bottom 10mm Also the item data should not be printed wi...

Page 63: ...n X value Y value Print Angle Print angle of each Print Item can be selected from 4 different angles 0 degree 90 degree 180 degree and 270 degree A whole format base or each Item Data base may set print angle According to the selected print angle the status of print position differs as the following samples All manuals and user guides at all guides com ...

Page 64: ...STIME 64 DUPLICATE UNIT PRICE 1 12 BARCODE 3 BARCD 66 BORN COUNTRY 1 BORN 13 SHOP NAME 2 SHOPN 67 FATTEN COUNTRY 1 FAT 14 DISCOUNT VALUE 1 DISCT 68 SLAUGTHER HOUSE 1 SLAUG 15 USED BY DATE 1 UDATE 69 CUTTING HALL 1 CUT H 16 LOGO 2 LOGO 70 REFER NO 1 FEF D 17 MAIN GROUP CODE 1 MG CD 71 ORIGIN 1 ORIGI 18 DEPARTMENT CODE 1 DEPT 72 TEMPERATURE 1 TEMP 19 SCALE NUMBER 1 SCLNO 73 MULTI BARCODE 1 3 M1BAR 2...

Page 65: ...E 1 UDATE 6 PRICE TAX 1 PRTAX 20 BORN COUNTRY 1 BORN 7 PACKED TIME 1 PTIME 21 FATTEN COUNTRY 1 FAT 8 TOTAL TITLE 1 TOTAL 22 SLAUGTHER HOUSE 1 SLAUG 9 BARCODE 3 BARCD 23 CUTTING HALL 1 CUT H 10 CLERK 1 CLERK 24 REFER DATE 1 REF D 11 TEXT 17 2 TXT17 25 ORIGINAL COUNTRY 1 ORIGI 12 TEXT 18 2 TXT18 26 MULTI BARCODE 1 3 M1BAR 13 TEXT 19 2 TXT19 27 MULTI BARCODE 2 3 M2BAR 14 TEXT 20 2 TXT20 28 SERIAL NO ...

Page 66: ... 0 1 99 Enter Free Format setting programming mode Select Free Format File Number 1 S12 1 LABEL 0 WT MM Enter the Free Format File No 1 Ex No 1 4 8 S12 2 LABEL 0 HT MM Enter Label print width Ex 48mm 3 5 S12 3 LABEL 0 DG ANGLE Enter Label print height Ex 35mm or S12 3 LABEL 90 DG ANGLE or key can change the selection of label angle 0 90 180 270 degree S12 4 LABEL ITEM LABEL Label angle is turned 9...

Page 67: ... S12 5 PLUno 0 DG ANGLE Select print angle Ex 90 degree S12 5 PLUno 0 STATUS Enter print status Ex All item print 7 S12 5 PLUno S1 CHAR SIZE Select the character size Ex S5 four times S12 5 PLUno S5 CHAR SIZE or key can change the selection of the character size S1 S5 M1 M5 L1 L5 S12 5 PLUno 1 F ITEM Enter next item setting Note 1 STATUS TYPE 0 NO Print 3 Weighing Item 4 Non weighing Item 7 All It...

Page 68: ...and label type S12 5 SHOPN 13 F ITEM Item setting Shop name S12 5 SHOPN 0 X MM Enter X value Ex 10mm 1 0 S12 5 SHOPN 0 Y MM Enter Y value Ex 1mm 1 S12 5 SHOPN 0 DG ANGLE Select print angle Ex 180 degree S12 5 SHOPN 0 WT MM Enter width value The width of shop name printing area is 20mm Ex 20mm 2 0 S12 5 SHOPN 0 HT MM Enter height value The height of shop name printing area is 15mm Ex 15mm 1 5 S12 5...

Page 69: ...and label type S12 5 BARCD 12 F ITEM Item setting Barcode S12 5 BARCD 0 X MM Enter X value Ex 5mm 5 S12 5 BARCD 0 Y MM Enter Y value Ex 20mm 2 0 S12 5 BARCD 0 DG ANGLE Select print angle Ex 90 degree S12 5 BARCD 0 HT MM Enter height value The height of shop name printing area is 25mm Ex 25mm 2 5 S12 5 BARCD 0 STATUS Enter print status Ex All item print 7 S12 5 BARCD 7 STATUS The status of BARCODE ...

Page 70: ...type S12 5 FRM 1 22 F ITEM Item setting Frame 1 S12 5 FRM 1 0 X MM Enter X value Ex 10mm 1 0 S12 5 FRM 1 0 Y MM Enter Y value Ex 1mm 1 S12 5 FRM 1 0 X1 MM Enter X1 value The X1 of frame 1 printing area is 20mm Ex 20mm 2 0 S12 5 FRM1 0 Y1 MM Enter Y1 value The Y1 of frame 1 printing area is 15mm Ex 15mm 1 5 S12 5 FRM 1 0 STATUS Enter print status Ex All item print 7 S12 5 FRM 1 0 T MM Enter line we...

Page 71: ...Store the free format file 1 back to S mode Note1 Another way to select the existing label format to copy by press Key or Key 3 16 6 Free Format Delete Function The Free Format Label cannot be deleted when the label is linked to existing PLU file At Free Format programming mode enter existing Free Format Number Ex 1 to be deleted DISPLAY OPERATION PT kg kg REMARK S12 0 FREE 0 1 99 Enter Free Forma...

Page 72: ...E 67 3 16 7 Sample of program a format by modifying the existing format You can create your desired label format by copying an existing format and modifying it to your needs All manuals and user guides at all guides com ...

Page 73: ...the existing label format you want to be copy Ex T8 S12 1 LABEL 56 WT MM Change label width Ex No change S12 2 LABEL 55 HT MM Change label height Ex No change S12 3 LABEL 0 DG ANGLE Change print angle Ex No change S12 4 LABEL ITEM LABEL Select Item Label S12 5 PLUno 1 F ITEM Enter item setting S12 5 PLUno 7 STATUS Enter PLU Number print Status mode C or 0 S12 5 PLUno 0 STATUS Change the status to ...

Page 74: ...Ingredient programmable mode 2 S12 5 INGR 0 Y MM Enter X Position value Ex 2mm and go to next selection 2 3 S12 5 INGR 0 DG ANGLE Enter Y Position value Ex 23mm and go to next selection S12 5 INGR 0 WT MM Change print angle Ex No change 5 4 S12 5 INGR 0 HT MM Enter WIDTH value Ex 54mm and go to next selection 1 0 S12 5 INGR 0 STATUS Enter HEIGHT value Ex 10mm and go to next selection 7 S12 5 INGR ...

Page 75: ... NO SET Enter Place File programming mode 1 S15 1 P01 01 S1 A100 Enter place file No Ex No 1 M A D E SP S15 1 P01 13 DIGI S1 A 88 Enter the Place File as the same procedures as Commodity Name Entry Ex MADE IN DIGI SIZE SIZE S15 1 P01 13 DIGI S5 A 48 Change font size to S5 S1 S5 M1 M5 L1 L5 PLU S15 PLACE FILE Store Place File 1 back to S mode 3 17 2 Delete Place File At Place programming mode enter...

Page 76: ...S mode 1 6 S16 0 RATE 0 00 DISC Program Machine Code 5 0 0 S16 0 RATE 5 00 DISC Enter default discount rate Ex 5 00 S16 MACHIN SETTING Store machine setting back to S mode Note1 0 to 99 99 are available for Default Discount Rate All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 77: ...ts and 64 vertical dots However since the Label logo data is printed within the limits which are programmed in label formats program the logo data within the limits of print area on the format Note All standard formats have 37 dots x 30 dots for logo print area 3 19 1 Pre programming Logo Data 1 Prepare a section paper with 128 horizontal dots and 64 vertical dots 2 When programming Label Logo dra...

Page 78: ...play appears when entering Logo Program Mode Key Function for LOGO Set Up 0 Clear a dot 1 Fill a dot Move the cursor to left I Move the cursor to right J Move the cursor to up K Move the cursor to down L Move up to the first dot in the next line PLU Store the Data All manuals and user guides at all guides com ...

Page 79: ...umber Ex 1 1 S17 1 LOGO 0 X POS Enter X position Ex 7 dots 7 S17 2 LOGO 0 Y POS Enter Y position Ex 1dots 1 S17 3 LOGO 000000 007 01 Set Fill or Clear dots you want and the save the setting and go to next upper line Y 02 Ex 11101110001 1 1 0 1 S17 3 LOGO 000000 001 02 Press key to move the cursor to next dot Press key 6 times S17 3 LOGO 000000 007 02 If necessary to change the position of the curs...

Page 80: ... LOGO 0 NO SET Enter Logo File programming mode 1 S17 0 LOGO 1 NO SET Enter Logo File number 1 S17 0 LOGO DEL Y C N T Enter delete mode C for Yes T for No C S17 LOGO FILE Delete Logo File 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Logo File can not be deleted All manuals and user guides at all guides com ...

Page 81: ...abel format must has print area for Price Tax and SPEC 659 SELECTION OF ITEM PRICE PRINTING must set to ITEM PRICE AFTER TAX in advance 3 20 1 Program Tax File At Programming Mode select TAX programming mode and then enter new Tax number Ex 1 programming mode For edit enter existing Tax number DISPLAY OPERATION PT kg kg REMARK S1 PLU FILE Enter S mode 1 8 S18 0 TAX 0 NO SET Enter Tax File programm...

Page 82: ...existing Tax Number Ex 1 to be deleted DISPLAY OPERATION PT kg kg REMARK S18 0 TAX 0 NO SET Enter Tax File programming mode 1 S18 0 TAX 1 NO SET Enter Tax File number 1 S18 0 TAX DEL Y C N T Enter delete mode C for Yes T for No C S18 TAX FILE Delete Tax File 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Tax File can not be deleted All manuals and ...

Page 83: ...13 1 SC MG STORE 21 Enter Scroll Message Ex WELCOME TO DIGI STORE PLU S13 SCROLL MESSAGE Store the Scroll message 1 data back to S mode 3 21 2 Delete Scroll Message File When the Scroll message number is linked to Scroll Sequence it can t be deleted At Scrolling Message program mode enter existing Scroll Message Number Ex 1 to be deleted DISPLAY OPERATION PT kg kg REMARK S13 0 SC MG 0 NO SET Enter...

Page 84: ...C SQ 0 NO SET Enter Scrolling Sequence programming mode 1 S14 1 SC SQ MSG NO 000 Enter Scrolling Sequence file number Ex 1 1 2 3 S14 2 SC SQ ATTRIB 123 000 Enter existing Scrolling Message Number Ex 1 2 3 1 2 3 S14 2 SC SQ SPEED 123 000 Select Scrolling pattern for each Scrolling Message Ex MSG 1 1 MSG 2 2 MSG 3 3 1 2 0 S14 2 SC SQ SPEED 123 120 Select Scrolling Rate Ex MSG 1 1 NORMAL MSG 2 2 FAST...

Page 85: ... SET Enter Scrolling Sequence programming mode 1 S14 0 SC SQ 1 NO SET Enter Scrolling Sequence file number Ex 1 PLU S14 SCROLL SEQUENC Enable Scrolling Sequence Number 1 back to S mode Note1 If you want to change the Scroll Sequence number enter new sequence number follow by press PLU key Disable Scrolling Message At Scroll Sequence programming Mode enter Scroll Sequence Number you want Ex 0 DISPL...

Page 86: ... REMARK S14 0 SC SQ 0 NO SET Enter Scrolling Sequence programming mode 1 S14 0 SC SQ 1 NO SET Enter Scrolling Sequence file number Ex 1 S14 0 SC SQ DEL Y C N T Enter delete mode C for Yes T for No C S14 SCROLL SEQUENC Delete Scrolling Sequence Number 1 back to S mode Note1 If you want to cancel the deletion press T key to exit Note2 Non existing Scroll Sequence File can not be deleted All manuals ...

Page 87: ...d 1 Operation ASCII Display Indicate Remarks Depress the key one time INPUT A A Lamp P turns on note 1 Depress the key two times INPUT a a Lamp P turns off note2 Depress the key three times INPUT 1 1 Lamp P turns off note3 Note1 Lamp P turning on indicates capital letter is use in PLU programming Note2 After one letter input the indicator under the letter is flicker 1 5 seconds Note3 When the indi...

Page 88: ...ess CODE to switch to ASCII Code Input 6 7 S1 3 C01 02 A S1 A 21 ASCII Code 67 figures Character C 6 5 S1 3 C01 03 A S1 A 20 ASCII Code 65 figures Character A 7 5 S1 3 C01 04 A S1 A 19 ASCII Code 75 figures Character K 6 9 S1 3 C01 05 A S1 A 18 ASCII Code 69 figures Character E CODE S1 3 C01 01 CAKE S1 A 18 Switch to key in method The inputted characters will be displayed in the Unit Price window ...

Page 89: ...8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Stand by status 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Power off ON OFF 4 2 Reset and Weighing Check All weighing operations will be performed based on the procedure shown below Operator should check this operation before any transactions 1 ZERO 2 NET 3 FIX T 4 FIX P OPERATION KEYS PT kg Kg kg 1 2 3 4 Stand by statu...

Page 90: ... 0 0 0 0 0 0 0 0 0 Remove the tare weight 0 0 3 0 0 0 3 0 0 0 0 0 0 0 Clear the tare weight T 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 3 2 Digital tare Subtraction 1 ZERO 2 NET 3 FIX T 4 FIX P OPERATION KEYS PT kg Kg kg 1 2 3 4 Stand by status 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Key in the tare weight e g 5g 5 0 0 0 0 0 0 0 0 0 0 5 0 0 0 Subtract the tare weight Assume 15kg T 0 0 0 5 0 0 0 5 0 0 0 0 0 0 Clear the ta...

Page 91: ... 0 Enter the PLU No of the Beef steak Ex No 10 0 1 0 0 0 0 0 0 0 0 0 1 00 0 0 0 Press PLU key PLU 0 0 0 0 0 0 0 0 1 2 0 0 0 0 Clear the PLU and return to Stand by status C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 4 2 PLU Call Up by Preset Key To enable this function the PLU must assign on the Preset Key in advance 1 ZERO 2 NET 3 FIX T 4 FIX P OPERATION KEYS PT kg Kg kg 1 2 3 4 Stand by status 0 0 0 0 0 0 0 0...

Page 92: ... tare weight 0 0 4 0 0 0 4 0 0 0 0 0 0 0 Key in the tare weight e g 50g 5 0 0 0 4 0 0 0 4 0 0 5 0 0 0 0 Set new tare and cancel fix tare by T key T 0 0 5 0 0 0 5 0 0 0 0 0 0 0 Fix tare FIX 0 0 5 0 0 0 5 0 0 0 0 0 0 0 Clear the tare weight and fix tare T 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 5 2 Fix PLU by FIX Key 1 ZERO 2 NET 3 FIX T 4 FIX P OPERATION KEYS PT kg Kg kg 1 2 3 4 Stand by status 0 0 0 0 0 0 0...

Page 93: ...ear unit price and fix unit price C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 6 Operation Mode Change 1 ZERO 2 NET 3 PREPACK 4 MANUAL 5 LABEL OPERATION KEYS PT kg Kg kg 1 2 3 4 5 Receipt mode 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Depress MODE key while depressing REZERO 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 REZERO key REZERO MODE LABEL MODE Set to label manual mode 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Depress MODE key whi...

Page 94: ... 0 0 0 1 2 0 0 0 0 Place the product on the platter e g 1kg 0 0 0 0 1 0 0 0 1 2 0 1 2 0 Print out one item label 0 0 0 0 1 0 0 0 1 2 0 1 2 0 Remove the product from the platter C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 For example Sell one pack of SMOKED SAUSAGE Ex PLU 30 and sell five packs of SLICED BACON Ex PLU 40 Non weighing Item 1 ZERO 2 NET 3 FIX T 4 FIX P 5 MANUAL 6 LABEL OPERATION KEYS PT kg Kg kg 1 ...

Page 95: ...le Enter the Price for Non PLU item Ex 5 00 by numeric key Note For Non weight Item just press key to issue out a label or press X key to enter multiply mode then enter sale quantity and press key to issue label 1 ZERO 2 NET 3 FIX T 4 FIX P 5 MANUAL 6 LABEL OPERATION KEYS PT kg Kg kg 1 2 3 4 5 6 Stand by status 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Enter the unit price 5 0 0 0 0 0 0 0 0 0 0 5 0 0 0 0 0 Mult...

Page 96: ... 2 NET 3 V1 4 V2 5 V3 6 V4 OPERATION KEYS PT kg Kg kg 1 2 3 4 5 6 Stand by status 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Enter the PLU No of the HERB CHEESE 3 PLU 0 0 0 0 0 0 0 0 5 0 0 0 0 0 Place the product on the platter 1 5kg 0 0 0 0 1 5 0 0 5 0 0 7 5 0 Register sales item to Vender1 V1 V1 TOTAL 1PCS 7 5 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Enter the PLU No of the SKIM MILK 3 0 2 PLU 3 0 0 PR PCS Enter the se...

Page 97: ... value Ex 0 20 2 0 V1 DISC 0 20 Confirm V1 TOTAL 1PCS 1 00 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 8 3 PRICE DISCOUNT Function Key in Add Mode This function key is used to get the desirable discounted total price in Add Mode by setting the discount value from the original total price when issuing total label or receipt The formula is shown as follows PRICE TO PAY ORIGINAL TOTAL PRICE x 100 DISCOUNT VALUE ...

Page 98: ...hted item in the last transaction Transaction Example Vender 1 1 1kg of BEEF STEAK 2 One pack of Smoked Sausage 3 More 5kg of BEEF STEAK But customer canceled 5kg of BEEF STEAK accumulated in the last operation 1 ZERO 2 NET 3 V1 4 V2 5 V3 6 V4 OPERATION KEYS PT kg Kg kg 1 2 3 4 5 6 Stand by status 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Enter the PLU No of the Beef Sirloin 1 0 PLU 0 0 0 0 0 0 0 0 1 2 0 0 0 0 ...

Page 99: ... 0 0 0 0 0 1 2 0 0 0 0 Place the product on the platter e g 1kg 0 0 0 0 1 0 0 0 1 2 0 1 2 0 Register sales item to Vender1 V1 V1 TOTAL 1PCS 1 2 0 Remove the product from the platter C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Enter the PLU No of the Smoked Sausage 3 0 PLU 2 5 0 PR PCS Register sales item to Vender1 V1 V1 TOTAL 2PCS 3 7 0 Enter the PLU No of the Beef Sirloin 1 0 PLU 0 0 0 0 0 0 0 0 1 2 0 0 0 0 P...

Page 100: ...r the PLU No of the FRIED POTATOES Ex PLU 8 8 PLU 0 0 0 0 0 0 0 0 2 2 3 0 0 0 Place the product on the platter e g 1kg The label automatically issued 0 0 0 0 1 0 0 0 2 2 3 2 2 3 Remove the product from platter and take the label off 0 0 0 0 0 0 0 0 2 2 3 0 0 0 Repeat the above 3 and 4 step to weighing the next pack until the last packed is weighed 0 0 0 0 0 0 0 0 0 0 0 0 0 0 For example issue 20 l...

Page 101: ...g 1 2 3 4 5 6 At Pre pack Mode 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Enter the unit price Ex 5 00 5 0 0 0 0 0 0 0 0 0 0 5 0 0 0 0 0 Place the product on the platter e g 1kg The label automatically issued 0 0 0 0 1 0 0 0 5 0 0 5 0 0 Remove the product from platter and take the label off 0 0 0 0 0 0 0 0 2 2 3 0 0 0 C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Note1 For Non weight Item just press key to start issuing out a l...

Page 102: ...No 99 MAIN GROUP No 1 No 999 UPPER LIMIT DEPARTMENT No 1 No 99 MAIN GROUP No 1 No 999 5 2 Report Type Selection There are two ways to select the Report Type by using different keys such as Preset keys that the desired Report Type is assigned to By press X or key to select the Report Type Enter Report Mode X Mode from Stand by Status DISPLAY OPERATION PT kg kg REMARK 0 000 0 000 0 00 0 00 Stand by ...

Page 103: ...SM 110 READ REPORT MODE 98 All manuals and user guides at all guides com ...

Page 104: ... Enter ending M G Ex 996 9 9 6 REPORT PRINTING Print M G daily Read Report X1 1 READ MGROUP DAILY Display back to X mode or or X X1 4 READ MG TERM Select M G Term Read Report X1 4 1 ST NUM Enter starting M G Ex 3 3 X1 4 3 ED NUM Enter ending M G Ex 996 9 9 6 REPORT PRINTING Print M G Term Read Report X1 4 READ MG TERM Display back to X mode 5 2 2 PLU Report Printing report order for PLU Daily Term...

Page 105: ...to X mode 5 2 3 Department Report Printing report order for DEPARTMENT Daily Term Read Report For example DEPARTMENT LOWER LIMIT 3 DEPARTMENT UPPER LIMIT 96 DISPLAY OPERATION PT kg kg REMARK Enter X mode X1 1 READ MG DAILY Lamp X turns on or or X X3 1 READ DEPT DAILY Select Dept Daily Read Report X3 1 1 ST NUM Enter starting Dept Number Ex 3 3 X3 1 3 ED NUM Enter ending Dept Number Ex 96 9 6 REPOR...

Page 106: ...X5 1 READ 24 HOUR DAILY Select 24 HOUR Daily Read Report REPORT PRINTING Print 24 HOUR Daily Read Report X5 1 READ 24 HOUR DAILY Display back to X mode or or X X5 4 READ 24 HOUR TERM Select 24 HOUR Term Read Report REPORT PRINTING Print 24 HOUR Term Read Report X5 4 READ 24 HOUR TERM Display back to X mode 5 2 6 ABC Report ABC Report is used to check the sales situation of PLUs The share of PLUs a...

Page 107: ... ABC TERM Select ABC Term Read Report X6 4 1 ST NUM Enter starting PLU NO Ex 1 1 X6 4 1 ED NUM Enter ending PLU NO Ex 999 9 9 REPORT PRINTING Print ABC Term Read Report X6 4 READ ABC TERM Display back to X mode 5 2 7 Clerk Report Clerk report is used to print out the total data such as total prices total quantity and so on by every Clerk For example Printing report order for CLERK Daily Read Repor...

Page 108: ...AILY Lamp X turns on or or X X8 1 READ PPK DEPT DAILY Select Pre pack Department Daily Read Report X8 1 DEPT 1 ST NUM Enter starting Dept Number Ex 1 1 X8 1 DEPT 1 ED NUM Enter ending Dept Number Ex 99 9 9 REPORT PRINTING Print Pre pack Department Daily Read Report X8 1 READ PPK DEPT DAILY Display back to X mode or or X X8 2 READ PPK MG DAILY Select Pre pack Main Group Daily Read Report X8 2 DEPT ...

Page 109: ...ly Read Report X9 4 1 ST NUM Enter starting Tax Number Ex 1 1 X9 4 1 ED NUM Enter ending Tax Number Ex 3 3 REPORT PRINTING Print Tax daily Read Report X9 4 READ TAX Display back to X mode 5 2 10 Store Summarized Report DISPLAY OPERATION PT kg kg REMARK Enter X mode X1 1 READ MG DAILY Lamp X turns on or or X X4 3 READ STORE SUMMARY Select Store Summarized Daily Read Report REPORT PRINTING Print Sto...

Page 110: ...No C Z1 0 RESET SALES DAILY Display back to Z mode or or X Z2 0 RESET SALES MONTHLY Select Sales Monthly Reset Report RESET REPORT Y C N T Enter Reset mode C for Yes T for No C Z2 0 RESET SALES MONTHLY Display back to Z mode or or X Z3 0 RESET SALES TERM Select Sales Term Reset Report RESET REPORT Y C N T Enter Reset mode C for Yes T for No C Z3 0 RESET SALES TERM Display back to Z mode All manual...

Page 111: ...20 20 December 2005 1 TITLE REVISION NO ISSUED DATE SM 110 SPECIFICATION LIST 0 17 August 2004 Rev No Modification Details Software Version 0 First Release 1 00 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 112: ... F2 for 13 Digits Non PLU Barcode 9 Enter value from range 0 to 99 04 Flag Data F1 and F2 for 13 Digits PLU Barcode 9 Enter value from range 0 to 99 05 Flag Data F2 for 8 Digit Non PLU Barcode 9 Enter value from range 0 to 9 06 Flag Data F1 and F2 for 8 Digit PLU Barcode 9 Enter value from range 0 to 99 07 Total Barcode 9 0 F1F2 CCCCC XCD XXXX CD 12 F1X2 CCCCC XCD XXXX CD 1 F2 CCCCCC XCD XXXX CD 1...

Page 113: ... DD YY 2 YY MM DD 1 DD MM YY 3 Not Used 18 1 or 2 Line s Commodity Name on Receipt 9 0 2 Lines 2 No Print 1 1 Line 19 Label Printing by Clerk Key 9 0 No Print 2 Print without Accumulated 1 Print with Accumulation 20 Total Label Printing 9 0 No Print 1 Print 21 Printing Operator Name on Receipt and Label 9 0 Code 1 Name 22 Receipt Paper Width 8 0 60 mm 2 50 mm 1 40 mm 23 Manual Price Entry for Prin...

Page 114: ...for Label in Prepack Mode 9 0 Inhibit 1 Allow 30 Selection of CDV 8 0 Inhibit 1 Allow For SF only 31 CDV Type 8 0 CDV 1 Tear off For SF only 32 CDV Modulus 8 0 Modulus 10 1 Modulus 11 For SF only Effective when SPEC30 and 31 1 33 On Spot Correction 9 0 Allow 1 Inhibit 34 Search Correction 8 0 Allow 1 Inhibit 35 Move Back Correction 9 0 Allow 1 Inhibit 36 Past Sales Data Correction 0 Allow 1 Inhibi...

Page 115: ...net I F are SPEC50 135 214 50 Setting of Client Server 9 0 Client 2 Backup Server 1 Server Workstation Related SPECs for S C setting are SPEC61 150 163 165 187 194 208 229 252 253 254 255 265 276 51 Baud Rate of SIO RS 232C Port 9 0 1 200 bps 4 19 200 bps 1 2 400 bps 5 38 400 bps 2 4 800 bps 6 76 800 bps 3 9 600 bps Apply to both RS 232C and RS 485 ports setting for SM 300 Related SPECs are SPEC48...

Page 116: ...le 1 Enable Exclude AA 63 SM 90 and DI 10 RS 232C Communication 8 0 No 1 Yes 64 Enable Password Mode 9 0 Allow 2 Allow Multi Password 1 Inhibit 65 Report Printing in Daily and Term Transaction Clear 9 0 Inhibit 1 Allow 66 Pack Quantity Function Key Enable 0 Allow 1 Inhibit 67 Advertisement Function Key Enable 9 0 Allow 1 Inhibit 68 Fixed Total Price Discount Function Key Enable 9 0 Allow 1 Inhibit...

Page 117: ...d Total Price Markdown 84 Sub total Function Key Enable 9 0 Allow 1 Inhibit 85 Grand Total Function Key Enable 9 0 Allow 1 Inhibit 86 Label Sensor Gap Value 8 Enter value range from 0 to 255 87 Label Type 9 0 Gap 1 No Gap 88 Sell by Date Title Print out 8 0 Inhibit 1 Allow For AA only 89 ASCII Code Entry in S Mode 8 0 Inhibit 1 Allow For AA only 90 Sub total Markdown 9 0 No Markdown 1 Markdown 91 ...

Page 118: ...rice 103 Unit Price Assignment Function Key for PLU 0 Enable 1 Disable 104 Discount Price Rounding Method 9 0 Rounding 2 Cut Up 1 Cut Down 105 Fixed Total Price Markdown Function Key Enable 9 0 Allow 1 Inhibit 106 Total Price Percentage Markdown Function Key Enable 9 0 Allow 1 Inhibit 107 Fixed Unit Price Markdown Function Key Enable 9 0 Allow 1 Inhibit 108 Fixed Unit Price Percentage Markdown Fun...

Page 119: ...er 1 Thin Character For AA only 122 Prepare Mode after Power On 8 0 Manual Mode 1 Prepack Mode Always set to 0 for SM 200 123 Printing Thank You Message on Receipt 8 0 Enable 1 Disable 124 PLU Unit Price after Discount 9 0 Unit Price after Discount 1 Unit Price Discount Amount 125 Position of Special Message on Receipt 9 0 Bottom 1 Top 126 Function Keys Protection for Self service 8 0 No Protectio...

Page 120: ...YYY 142 Selection of Day Display for Sell by Date 9 0 Disable 1 Enable 143 Peel Sensor Trigger Voltage 8 0 High 1 Low 144 Display Prepack Quantity Balance 8 0 Enable 1 Disable 145 Print Select Function Across the Board 0 Disable 1 Enable 146 Label Format 1 2 Function Key Enable 0 Inhibit 1 Allow Exclude AA 147 Prepack Non add Function Key Enable 0 Inhibit 1 Allow Exclude AA 148 FIS3000 Code 8 0 SM...

Page 121: ... 163 Transaction Data Store in Client Memory 0 Disable 1 Enable 164 Maximum Label Length 8 0 120 mm 1 240 mm 165 Update Report for Client Server System 0 Yes 1 No 166 Average Price and Weight Label Function 0 Disable 1 Enable 167 Label Date Title Print 9 0 No Print 1 Print Exclude AA 168 GB Code 8 0 GB Code 1 Shift GB Code For CN and MS only 169 Print PLU Setting Unit in Manual Mode 0 No 1 Yes 170...

Page 122: ...PEC158 1 185 Weigh PLU Can Use for Non weigh PLU and Vice Versa Function Key Enable 0 Disable 1 Enable 186 Print and Weight Unit on Label 9 0 No Print 1 Print 187 Clear Total Data by Server 0 Both Server and Client 1 Server 188 Tare Decimal Point Left Shift for SM 25 FIS3D 8 0 No 1 Yes 189 PLU Auto Delete 0 No Delete 2 30 Days 1 15 Days 3 90 Days 190 Swap Weight and Unit Price on Receipt 8 0 No 1 ...

Page 123: ...2 3 Pages by Shift Key 1 3 Pages by Toggle 204 Reference PLU Function Key Enable 0 Inhibit 1 Allow 205 Print Function Key Enable 8 0 Inhibit 1 Allow 206 Print Barcode when Right Side Data Overflow 0 No print 1 Print Barcode Digits 207 Weight Decimal Point Position for Barcode and Label Printing 8 0 Same as SPEC607 1 0 000 Effective when SPEC607 2 208 Network Time Out 0 3 sec 2 x4 1 x2 3 x10 209 FS...

Page 124: ...n Key Enable 8 0 Inhibit 1 Allow 222 Open Cash Drawer without Sales Function Key Enable 9 0 Inhibit 1 Allow 223 Negative Unit Price Function 8 0 Disable 1 Enable 224 FIS3000 Wire Type 8 0 4 wires 1 2 wires 225 Prepack Grand Total for Individual PLU 0 Yes 1 No 226 Reverse Calculation of ITF Check Digit 0 No 1 Yes 227 Unit Price Override Password Function 0 Inhibit 1 Allow Effective when SPEC178 1 2...

Page 125: ...scount without Limit Function Key 0 Inhibit 1 Allow 243 Concatenate Commodity Name Display 8 0 No 1 Yes 244 Enable PLU Price Change Flag 0 No 1 Yes 245 Print Sell by Date or Used by Date when Date Equals Packed Date 0 Yes 1 No 246 Print First and Check Digits Outside Barcode 0 No 1 Yes 247 Print Packed date 9 0 Manual and Prepack Mode 2 Prepack Mode 1 Manual 3 No Print 248 Print Sell by Date 9 0 M...

Page 126: ...e 1 Enable 262 Selection of Receipt Label 8 0 Label 1 Receipt Always set to 1 for SM 200 263 FSD Net Value Minimum 8 0 Off 1 On For U1 only 264 Print Ingredient Data on Next Label 0 Disable 1 Enable 265 Client Using Local Free Format Label 0 No 1 Yes 266 FSD Weight 8 0 Back Computed Single Range 2 Exact Weight 1 Back Computed Dual Range For U1 only 267 CPDL Language Selection 8 0 First Language 1 ...

Page 127: ...erence No 1 By Reference No 4 By Date and PLU No 2 By PLU No 279 U1 Self service 8 0 Disable 1 Enable For U1 only 280 Real Time Customer Number 0 No 1 Yes 281 Real Time Buffer Receipt 8 0 Detail 1 Total Only 282 Barcode Function 8 0 Without CR 1 With CR 283 Barcode Look up table LUT Contents 8 0 Non weigh Item Only 1 All Items 284 Open Cash Drawer on Credit Payment 9 0 Allow 1 Inhibit 285 Australi...

Page 128: ...nt in Receipt 8 0 No 1 Yes 298 Traceability Update Function 0 No 1 Yes 299 Keyboard Selection 8 0 Normal Keyboard 2 80 Preset Keys 1 100 Preset Keys 32 56 Preset Keys Identical to SPEC672 300 SM 500 Self Service 8 0 No 1 Yes 96 Preset Keyboard Identical to SPEC688 301 Print Receipt after Accumulation 9 0 Yes 1 No 302 Fixed Port Number for Ethernet Enter value from 1 to 254 303 DHCP IP Address Leas...

Page 129: ...tion 9 0 No 1 Yes 318 Wireless FTP Port Number Enter value range from 1 to 9999 Not in used 319 Delete Traceability Record 9 0 Yes 1 No 320 PLU Link to Text Field 0 Disable 1 Enable 321 Julian Date for Packed and Sell Date 8 0 No 1 Yes For U1 only 322 Price Printing Size Large Font 0 No 1 Yes 323 Auto PLU Broadcasting 0 Disable 1 Enable 324 Decimal Point For Unit Price And Total Price 8 0 Disable ...

Page 130: ...6 2 F2 7 F7 3 F3 8 F8 4 F4 338 Traceability Barcode 0 EAN13 1 EAN128 339 Flag Data EAN13 Enter range from 0 to 99 340 Enforce Scan 0 No 1 Yes 341 TVP2000 SM300 0 Not Send T10 1 Send T10 Label Format 342 LCD 1 Line Scroll 0 Disable 1 Enable 343 Clear Key in Prepack 0 Enable 1 Disable 344 Print Pack Date 0 Yes 1 No 345 Update Spec For Server Client System 0 Enable 1 Disable 346 Update Label Turn ove...

Page 131: ...V1 20 20 December 2005 21 SPEC NO SPECIFICATION DESCRIPTION SM 100 350 Additional Rounding In Receipt 0 Print 1 No Print 351 Gratuitous ARP 0 Disable 1 Enable All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 132: ... 1 Inhibit 408 One or Two Touch for Receipt Printing in AMT TEND 9 0 One Touch 1 Two Touch 409 PLU Number Printing on Receipt 9 0 Inhibit 1 Allow 410 Sale Item Entry Method 9 0 Total 1 Item 411 Default Vender Transaction by Print Key 9 0 Allow 1 Inhibit 412 Print Checking Line 9 0 Print 1 No Print 413 Source of Used by Date 9 0 Current Date 1 Packed Date 414 In Store Barcode for Barcode Scanner En...

Page 133: ...are Weight when Unit Price is 0 9 0 Allow 1 Inhibit 427 Eliminate Cash Line on Receipt when No change Operation 9 0 Allow 1 Inhibit 428 PRINT Tax List on Receipt 9 0 Allow 1 Inhibit Effective when SPEC603 1 429 Non Weigh PLU Unit Price Display 9 0 Total Price Column 1 Unit Price Column 430 Items on PLU Main Group Dept Tax Report 9 0 Registered Items 1 All Items 431 Eliminate Vender Data on Sales R...

Page 134: ... Second Currency 9 0 None 2 0 00 1 0 0 3 0 000 445 Unit Price Change for PLU after Label Printing 9 0 Inhibit 1 Allow 446 Print Tare Weight on Receipt 0 Allow 1 Inhibit 447 Place Change for PLU after Label Printing 9 0 Inhibit 1 Allow For KE only 448 Sell Date Change for PLU after Label Printing 9 0 Inhibit 1 Allow For KE only 449 Trace Auto Clear 0 Inhibit 1 Allow For KE only 450 Trace per PLU 0 ...

Page 135: ...Enter item code length Press S46 3 F BAR 0 DATA1 Enter data format for DATA1 0 for weight 1 for quantity 2 for unit price 3 for weight quantity 4 for total price 5 for original price 6 for user programmable Press S46 4 F BAR 0 DIGIT Enter DATA1 length Press S46 5 F BAR 0 SHIFT Shift for DATA1 0 for no right shift 1 for right shift 2 for right shift x2 3 for left shift 4 for left shift x2 5 for lef...

Page 136: ... 5 for left shift x3 Press S46 9 F BAR NO MIDDLE CD Press ⅹ to select the middle check digit Press S46 1 F BAR NO LAST CD Press ⅹ to select the last check digit Press S46 1 F BAR ITF BARCODE Press ⅹ to swith ITF and EAN barcode Press S46 FLEXI BARCODE Save the flexible barcode 1 Note See the Flexible Barcode Usage Note at 3 6 1 PLU programming in SM 110 Operation manual All manuals and user guides...

Page 137: ... S34 0 1 NO SET Program country No 1 C H I N A S34 1 COUN CHINA Name 5 Program country name CHINA S34 Æ COUNTRY FILE Save Country No 1 3 5 S35 Æ CUTTING HALL Enter cutting hall programming 1 S35 0 HALL 1 NO SET Program cutting hall No 1 1 S35 1 HALL 1 COUNTRY Program cutting hall country No 1 C U T S35 2 HALL CUT Name 3 Program cutting hall name CUT S35 Æ CUTTING HALL Save cutting hall No 1 All ma...

Page 138: ...name SLAUG S36 Æ SLAUGHTER HOUSE Save slaughter house No 1 4 7 S47 Æ KIND FLIE Enter kind file programming 1 S47 0 KIND 1 NO SET Program kind file No 1 M E A T S47 1 KIND MEAT NAME 4 Program kind name MEAT S47 Æ KIND FILE Save kind file No 1 4 8 S48 Æ CATEGORY FILE Enter category file programming 1 S48 0 CATEG 1 NO SET Program category No 1 B E E F S48 1 CATEG BEEF NAME 4 Program category name BEE...

Page 139: ...y programming 1 S37 0 TRACE 1 NO SET Program traceability No 1 1 S37 1 TRACE 1 BORN Choose born country No 1 1 S37 2 TRACE 1 FATTEN Choose fatten country No 1 1 S 37 3 TRACE 1 S HOUSE Choose slaughter house No 1 1 S37 4 S CNT 1 LNK 1 Choose link country No 1 for slaughter house 1 S37 5 TRACE 1 C HALL Choose cutting house No 1 1 S37 6 C CNT 1 LNK 1 Choose link country No 1 for cutting hall 1 S37 7 ...

Page 140: ...EED Choose breed No 1 C O N T S37 14 CONT CONT NAME 4 Program cont content CONT 0 6 0 3 1 0 S37 15 TRACE 060310 EAT D Program eat by date 06 03 10 5 0 0 0 S37 16 TRACE 5 000 WEGHT Program maximum weight 5kg S C D S37 17 S CD SCD NAME 3 Program S CD content SCD S N M S37 18 S NM SNM NAME 3 Program S NM content SNM S A D 1 S37 19 S AD1 SAD1 NAME 4 Program S AD1 content SAD1 S A D 2 S37 20 S AD2 SAD2...

Page 141: ...PLU ITEM press Set Item TRACE to PROGRAM and press to save PLU Programming When you edit PLU set S1 64 PLU to TRACE ALLOW and press Input traceability number and press to save In the end when you call the PLU and print label you ll see the traceability information on the label All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 142: ... you can print 10 images 5 Enter S1 PLU FILE to create PLU 6 Enter S1 50 PLU 0 IMAGE 1 to choose the template number for IMAGE 1 From No 70 No 81 7 Enter S1 59 PLU 0 IMAGE 10 to choose the template number for IMAGE 10 From No 70 NO 81 8 Set S1 81 PLU PRINT NUTRI to set nutrition print status to Print 9 Enter from S1 82 to S1 10 to input nutrition contents 10 For extra details on the Nutrition Fact...

Page 143: ...in Group Term X2 4 Read PLU Term X3 4 Read Department Term X4 4 Read Sales Term X5 4 Read 24 Hour Term X6 4 Read ABC Term X9 4 Read Tax X4 3 Read Store Summary Programming Mode S Mode S1 PLU File S2 Department File S3 Main Group File S4 Key Assignment S5 Shop Name File S6 Advertisement Message S7 Vender File S8 Date and Time S9 Special Message S10 Ingredient File S11 Text File S12 Free Format S13 ...

Page 144: ...t Packed Time or Not S1 23 Present or Key in Enabled when S1 22 is set to print S1 24 Packed Time Enabled when S1 23 is set to Key in S1 25 Cost Price S1 26 PLU Tare S1 27 Unit Symbol S1 28 Quantity S1 29 Type of Volume Discount S1 30 The 1st Target of Volume Discount S1 31 The Discount Value for the 1st Target S1 32 The 2nd Target of Volume Discount S1 33 The Discount Value for the 2nd Target S1 ...

Page 145: ...ked Time 8 Commodity 9 Quantity Unit 10 Sell by Date 11 Sell by Time 12 Barcode 13 Shop Name 14 Discount 15 Used by Date 16 Logo 17 Main Group Code 18 Department 19 Scale Number 20 Ingredient 21 Special Message 22 Frame 1 23 Frame 2 24 Tare 25 Clerk 26 Text 1 27 Text 2 28 Text 3 29 Text 4 30 Text 5 31 Text 6 32 Text 7 33 Text 8 34 Text 9 35 Text 10 36 Text 11 37 Text 12 38 Text 13 39 Text 14 40 Te...

Page 146: ...GNUM Commodity Name COMNAM Special Message SP MG Ingredient INGR Place of Production PLCNUM Image IMAGE Bonus BONUS Nutrition NUTRI ITF Selection ITFSEL Reference PLU REFPLU Security PLU SECPLU Coupled PLU COUPLU Discount Day of the Week DAY WK EAN 5 Digit Add on ADD ON Tax Number TAX 2nd Price PRICE2 Proportional Tare TARE Customer Discount CUSDIS Restaurant Discount RESDIS Staff Discount STADIS ...

Page 147: ...5 Reset Report Mode Z Mode Z1 0 Reset Sales Daily Z2 0 Reset Sales Monthly Z3 0 Reset Sales Term All manuals and user guides at all guides com ...

Reviews: