SM 110 PROGRAM MODE
30
3.6.1 Program PLU File(weighing item)
PLU data(weighing item) is programmed by following procedure as below.
If the selected 1
st
or 2
nd
label format does not have print area for the PLU items, the item will be skipped
automatically or not printed on label.
DISPLAY
OPERATION
PT
kg
$
/kg
$
REMARK
[MODE][MODE]
[MODE]
S1
→
PLU FILE
Enter S mode.
Lamp S turns on.
[*] S1.0
PLU
0
NO
SET
Enter PLU programming mode.
$
/kg window displays PLU number.
[1][0][0]
S1.0
PLU
100
NO SET
Enter new PLU Number (Ex. 100) you want.
[*] S1.1
PLU
0.00
PR-KG
Enter PLU programming.
Enter unit price.(Ex.5.80
$
/kg)
[5][8][0][*]
S1.2
PLU
DFT 0 LAB FR1
Select Label format for 1
st
Label by press [<<]
or [>>] key.
(T1~T12,S,A,B,C,F1~F8 is available)
[<<] or [>>]
S1.2
PLU
T6
6 LAB FR1
Set the Label format (Ex.T6) by press [6] or[>>]
key.
[*]
S1.3
PLU
NO
0 LAB FR2
Select Label format for 2
nd
Label by press [<<]
or [>>]key.
(F1~F8 only)
[<<] or [>>]
[*]
S1.4
C01.01
S1 A 100
Enter commodity name.(Ex. “SLICE”)
[S][L][I][C][E]
[*]
S1.4
C02.01
S1 A 100
Enter the 2
nd
line of commodity name.
[*] S1.5
PLU
EAN
BARCODE
Select the type of BARCODE by press [X] or
[>>].(EAN or ITF)
[*] S1.6
PLU
DFLT
BARCODE
Select barcode format by press [<<] or [>>]
key.(Ex.2f5c4i4wD)
[<<] or [>>]
[*]
S1.7 PLU 20
FLAG
Set flag data.(Ex.29)
The Default Flag Data can be set at SPEC 3 ~ 6
and the Flag data consists of one or two digits,
which depends on the selected Barcode type.
[2][9]
[*]
S1.8
PLU
00000
IT CODE
Enter item code.(Ex.10010)
All manuals and user guides at all-guides.com