Install Guide
Model: MIL-240FXC/MIL-240FXT
4
S p e c i fi c a t i o n s
D i m e n s i o n s :
4.0” x 3.5” x 1”
E n cl o s u r e :
Aluminum (.50 thick)
Pow e r S u p p ly
External power is required for the MIL-240FXT/240FXC. The system board draws
900 mA at normal operation in room temperature of 25 C.
– An 110 V AC wall mount for domestic use
– A 220 V AC with IEC socket converting to 5 V DC 1.5 Amp for international
use
C o n n e c t o rs
Figure 2. Connections
R e l i a b i l i t y
A 24 hour temperature cycling of 0° to 60° C without any dribble or BER
degraded.
S t o r ag e Te m p e r a t u r e
• Minimum: -25° C
• Maximum: 75° C
O p e r a t i n g C o n d i t i o n s
Table 1: Recommended Operation Conditions
Parameters
Minimum
Maximum
Operating Temperature
+5° C
+40° C
Humidity: Non-condensing
10%
95%
Signal Output Load
35 ohm
75 ohm
Supply Voltage
4.75 V
5.25 V
Ambient Operation
0
70
SC Connector
(rear view)
ST Connector
(rear view)