27
Weight and Measures Specification (continued):
Spec No.
Bit 3
Bit 2
Bit 1
Bit 0
20 Tare
Addition
0 = yes
1 = no
Dual Range
0 = multi gross
1 = multi net
Digital Tare
Setting
0 = no
1 = yes
Tare Range
0 = 50% of max
1 = 100% of max
21
Not used
Not used
Digital Tare
Rounding
0 = tare exactly
1 = round to
nearest
increment
Tare Auto Clear
0 = no
1 = yes
22
Not used
Not used
Not used
Not used
23
Not used
Not used
Not used
Not used
Load Cell Sensitivity Selection (mV/V)
24
Value
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Minimum
3.46
3.00
2.59
2.25
1.95
1.69
1.46
1.27
1.09
0.95
0.82
0.71
0.61
0.53
0.48
0.40
Maximum
4.00
3.46
3.00
2.59
2.25
1.95
1.69
1.46
1.27
1.09
0.95
0.82
0.71
0.61
0.53
0.46
25
Not used
Not used
Not used
Not used
26
Not used
Not used
Not used
Not used
27
Not used
Not used
Not used
Not used
28
Not used
Not used
Re-zero
Tracking Range
0 = +/- 2%
1 = unlimited
Power-On Start
Range
0 = +/- 10%
1 = unlimited
29
Not used
Not used
Not used
Enter weight for
Calibration
0 = no
1 = yes
"
"
"
"
new spec
ver1.10+
All manuals and user guides at all-guides.com
Summary of Contents for DS-470
Page 2: ...All manuals and user guides at all guides com ...
Page 8: ...5 3 4 RS 232 Cable Installation All manuals and user guides at all guides com ...
Page 9: ...6 3 5 1 DS 470 SS Unlocking Procedure All manuals and user guides at all guides com ...
Page 33: ...30 7 8 Shop Notes All manuals and user guides at all guides com ...