20
6.0.2. Transmit Set-Point Data To External Device
If Set-point data to an external device spec (spec 53 bit 2 ) is enabled and when
MAX key or MIN key is pressed in the in Operation mode, the scale would send DC2
or DC4 and the external device would receive the set-point data.
TEXT COMMAND
CR
The end of data
0DH
Termination code
LF
The end of text
0AH
0 –9
Numeric data
(30H – 39H)
Period Period (2EH)
Data
Comma Comma (2CH)
F
Set-point 1
(46H)
Header code
H Set-point
2
(48H)
DATA FORMAT:
Example 1: Send MINimum set -point by pressing
[MIN]
key and scale sends DC2 to
external device.
STX
Header
MIN Set-point
CR
LF
1 1 5 1
1
Example 2: Send MAXimum set -point by pressing
[MAX]
key and scale sends DC4
to external device.
STX
Header
MAX Set-point
CR
LF
1 1 5 1
1