DS-425 Service Manual
3.4. Gross / Net Display Toggle
Indication Flag: B - Bright S - Sparkling
1-ZERO 2-NET 3-STD 4-U.C 5-SAF 6-SAC 7-S1 8-S2 9-S3 10-S4
Indicator
Operation
Key
Weight
1 2 3 4 5 6 7 8 9 10
Remarks
Weight
Stable
0.0000 kg B B Weighing
mode
Load weight
(eg.0.6000kg)
0.6000
kg B Gross
weight
display
Excute tare
[Tare]
0.0000
kg B B Net
display
Toggle
[INC]
0.6000 kg B Gross
Weight
display
Remove
item
0.0000 kg B B Weighing
mode
Toggle
[INC]
-0.6000 kg B B B Net
weight
Tare
clear
[Tare]
0.0000 kg B B Weighing
mode
Note: The function is available when SPEC11 BIT0=1 only.
This function will be unavailable when Weight Unit Conversion function is enabled.
3.5. Weight Unit Conversion
Indication Flag: B - Bright S - Sparkling
1-ZERO 2-NET 3-STD 4-U.C 5-SAF 6-SAC 7-S1 8-S2 9-S3 10-S4
Indicator
Operation
Key
Weight
1 2 3 4 5 6 7 8 9 10
Remarks
Weight Stable
0.0000
k
g
B
B
Weighing
mode
Load weight
(eg.0.6000kg)
0.6000
k
g
B
Convert [INC]
1.3225
lb
B
Pound
display
Convert [INC]
21.165
o
z
B
Ounce
display
Convert [INC]
0.6000
k
g
B
Basic
unit
display
Remove items
0.0000
k
g
B
B
Weighing
Mode.
Note: This operation is available when SPEC15 = 0100 or 1100 only.
3.6. Counting Operation
Indication Flag: B - Bright S - Sparkling
1-ZERO 2-NET 3-STD 4-U.C 5-SAF 6-SAC 7-S1 8-S2 9-S3 10-S4
Indicator
Operation
Key
Weight
1 2 3 4 5 6 7 8 9 10
Remarks
Weight
Stable
0.0000 kg B B Weighing
mode
Press
[MODE] [Mode] Add
32
B Sample
number
32
Change number [Shift][Shift] Add
3
2
B
2
nd
digit selected
Chang value
[INC][INC] Add
5
2
B Sample
number
52
Confirm
[*]
0.0000 kg B B B Sample
weight
Load 52 samples
0.6000
kg
B B Weight
for
all
samples
Confirm
[*]
52
kg B B Counting
mode
Exit
[Mode] 0.6000 kg B B Weighing
mode
03 Main Operation