94
3.4 Print Adjustment
These options in this mode may control print performance. In most cases, these values
will not be needed to be changed at customer side.
Print performance can be controlled by setting Feed Value, Level of Detection, and Print
Contrast.
3.4a Feed Value Program
This measurement is factory set to 0, if the correct label size are set at PRINT SPEC.
However, if the print position is not proper, use this option to adjust the label present to
the proper value for printing.
F E E D V A L U E =
0
♦
♦
♦
♦
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
Key Functions : [ + ] key is used for the increment of the feed value. (Max = +127)
[ - ] key is used for the decrement of the feed value. (Max = -127)
[
→
(feed )] key is used for feeding label to check the proper feed value.
Programming Feed Value
1. Select Print Adjustment Mode in
Maintenance Mode by depressing [TARE
←
]
MEN: PRINT ADJUSTMENT
or [U.W
→
] keys.
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
2. Depress [ENTER] key.
ADJ = FEED VALUE
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
3. Enter FEED VALUE setting Mode by
FEED VALUE = 0
♦♦♦♦
All manuals and user guides at all-guides.com
Summary of Contents for DC-150
Page 2: ...1 SET UP 1 All manuals and user guides at all guides com ...
Page 14: ...13 2 PROGRAM MODE All manuals and user guides at all guides com ...
Page 69: ...68 3 MAINTENANCE MODE All manuals and user guides at all guides com ...
Page 99: ...98 All manuals and user guides at all guides com ...
Page 109: ...4 CHECK MODE 106 All manuals and user guides at all guides com ...
Page 119: ...5 OPERATION MODE 116 All manuals and user guides at all guides com ...
Page 133: ...Appendix I All manuals and user guides at all guides com ...