Operation

 

D3936-GB Rev C                                                     EZ3400VL User' s manual                                                                     

13

Change amount or number of animals 
a recipe 

 

 

 

 

 

 

1. 

Enter the “recipe programming” mode. 

See 

“Enter programming mode on page 12” 

2.  The first ingredient name is displayed 

followed by 

AMOUNT

3.  Use          or          to go to the ingredient/pen 

you want to change. 

4.  Change the amount/number of animals.  

5.  Press           to store the new 

amount/number of animals. 

Repeat steps 3-5 for each ingredient or pen you 
want to change. 

6.  When ready repeatedly press         until you 

see 

done

 

7.  Press          one more time to store the 

changes and leave the recipe 

Insert ingredient or pen in a recipe 

 

 

 

 

 

 

1. 

Enter the “recipe programming” mode. 

See 

“Enter programming mode on page 12” 

2.  Use          or           to go to the location 

where you want to insert an ingredient/pen. 

3. 

Press and hold        to insert a new 
ingredient/pen. 

 

Note: This will insert a new ingredient before 
the current ingredient on the screen. 

 

 

 

4.  Press          or         to scroll through the 

available ingredients/pens. 

5.  Press           to select the required 

ingredient/pen. 

6.  Enter the required amount/number of 

animals. 

7.  Press           to store amount. 

 

insert 

amount 

3

 

hay 

5/7 

done 

6/7 

Summary of Contents for EZ3400VL

Page 1: ...EZ3400VL User s manual Ft Atkinson Wisconsin USA Panningen the Netherlands www digi star com D3936 GB REV C June 24 2013 HELLO...

Page 2: ......

Page 3: ...ng ingredient names 15 Running a recipe according to amount per animal 16 ADVANCED FUNCTIONS 18 Holding the displayed amount 18 Backlight intensity 18 Preset presetting 18 Display in gross weighing mo...

Page 4: ...his manual in any form whatsoever without Digi Star s express written permission is forbidden The contents of this manual are subject to change without notice All efforts have been made to assure the...

Page 5: ...TS 10 5 to 16 0 V D C 160 mA nominal with four 350 L C SET UP AND CALIBRATION Via front panel GROSS RANGE 999 999 max display LOW BATTERY WARNING Enabled at 10 5V nominal POUND KILOGRAM Selectable DIS...

Page 6: ...Digi Star cannot be held responsible for deviations and problems arising from technical problems to the system Cleaning Do not use running water high pressure cleaners hoses to clean the indicator Ch...

Page 7: ...ill run self test 6 turns indicator off 7 Display Window Displays current actions 8 temporary zero Net mode 9 records to memory or prints displayed weight 10 toggles between Net and Gross weights 11 s...

Page 8: ...dd space in command 20 Serial port printer port communication with inputs and outputs of the computer and other digital devices optional 21 Port for remote display to connect the remote display option...

Page 9: ...ser s manual 9 OPERATION Switching on the weighing indicator 1 Press Switching off the weighing indicator 2 Press Zero balancing the weighing indicator 1 Press and hold for 3 seconds to zero balance t...

Page 10: ...xample with a total weight of 1000Kg this will be 550 kg silage and 450 kg corn Attention the total must be 100 3 Amount per ingredient Enter the required total amount per ingredient For example 2500...

Page 11: ...pe 1 Press and hold for 3 seconds 2 PRoGRm will briefly display followed by a The first programmed recipe or b rec __ This indicates that the memory is empty 3 Enter a new recipe number 4 Press to sto...

Page 12: ...or pen name by pressing the key See page 10 changing ingredient or pen name steps 5 through 8 for the procedure Please note that this will also affect other recipes where this ingredient pen is used...

Page 13: ...ready repeatedly press until you see done 7 Press one more time to store the changes and leave the recipe Insert ingredient or pen in a recipe 1 Enter the recipe programming mode See Enter programming...

Page 14: ...ress one more time to store the changes and leave the recipe Note If you want to insert an ingredient or pen at the end of the recipe go through the recipe until you see done and then press 1 Enter th...

Page 15: ...s to display first recipe Repeatedly press or to go to the recipe you want to print 2 Press to print this recipe 3 Press twice to print all the recipes saved in the memory 4 Press to return to normal...

Page 16: ...ingredient the total amount TOTamt will be displayed 6 After RESIZING all pens the indicator displays the first ingredient and amount to load While loading the ingredient the weight on the indicator c...

Page 17: ...Operation D3936 GB Rev C EZ3400VL User s manual 17 11 After the last pen has been fed the indicator displays done TOTAL comple...

Page 18: ...educe the backlight intensity by 60 Press again to return to the full intensity Preset presetting If you want to manually load or unload a specific amount you can enter a preset weight in the weighing...

Page 19: ...e gross weight While loading or unloading a preset amount the weighing indicator starts counting down The word PRESET and the required amount will be displayed alternately until 5 of the required amou...

Page 20: ...tare weight This function is used to trace the net content of for example a container that has already been filled If you know the empty weight of the container this tare weight can be entered in the...

Page 21: ...cal dots which briefly light up every second After the mixing clock has started the time on the display will count down to 00 00 00 1 Press 2 Enter the mixing time HH MM SS 3 Press to confirm the ente...

Page 22: ...on of select key PRGREC PRGREC PRGREC PRGREC Create or edit recipes 2 When the required option is displayed press to activate this option Calling up accumulative ingredient amounts Display the total a...

Page 23: ...ACCUM displayed 2 Press Press to display pens Press to display ingredients 3 Use or to go to the required ingredient pen 4 Press to print accumulation value for the ingredient pen 5 Press to exit Pri...

Page 24: ...ethod Enter value to activate early warning sign when indicator reaching preset value 1 Enter 401 press 2 Press to select WEIGHT or PERCNT 3 Press to save 4 Enter the pre alarm value in weight or perc...

Page 25: ...ght Delay time DELAY Enter the time that the weighing indicator should wait before advancing to the next ingredient 1 Enter 443 press 2 Enter delay time in seconds 3 Press to save NOTE Set to 0 preven...

Page 26: ...0VL User s manual 26 Drive ratio DRATIO Drive ratio is the number of revolutions of the power take off of the feed mixer divided by the number of revolutions of the mixer auger 1 Enter 422 and press t...

Page 27: ...ss to enter the selected menu 5 Press to scroll through the options 6 Press to change the options 7 Press to save the changes Changing setup and calibration numbers SETUP CAL 1 Enter 871 2 Press 3 Wei...

Page 28: ...lines or reservoirs Check all J Box and load cell cables for loose contacts cuts or pinched flat spots NO YES Are all values positive negative values indicate that the load cell concerned is mounted...

Page 29: ...ad cell connected Zero balance the weighing indicator and stand or hang with your weight over the connected load cell Note the weight increase A weighing indicator with only one connected load cell wi...

Page 30: ...ZP C 840459 SUPPORT HAT BRACKET D 405069 U BOLT 1 4 20 X 3 25 ZP E 405084 NUT 1 4 20 TOP LOCKING FLANGE F 403770 BRACKET WING MOUNT G 405124 PACK WEDGE MOUNT BRACKET WITH U BOLTS FLANGE NUTS H 405244...

Page 31: ...ections Power supply cable See figure 1 Weighing indicator Digital input output connection optional Remote display connection optional Power supply cable connection J Box connection Pin to 12Vdc power...

Page 32: ...load cell wires to terminals Tighten nuts Load cell cable J Box cable Wire colours Pin Colour Description 1 Red Power supply 2 Green Signal 3 White Signal 4 Black Power supply 5 Transparent Shield J...

Page 33: ...D RD2400V CAB CONTROL 2400 2400V 3400 3400V 3600 3600V Conformance to EN 61326 electrical equipment for measurement control and laboratory use see Report Number 307245 EN 55011 for Class B ISM equipme...

Reviews: