If Rain Stop is active it can be canceled manually anytime in the
Cancel Rain Stop screen. Once there, press
or
to
underscore Yes and press
to select. Press
or
again to underscore OK. Press
to
continue, this will bring back the Rain Stop screen.
5.3 MONTHLY BUDGET
Setting a Monthly Budget
Instead of changing the duration for each program, the Monthly
Budget feature is used to increase or decrease the amount of water
used during seasonally dry or wet periods on a monthly basis.
Budget adjustments can range from 10-200% in 10% increments. The LEIT controller will automatically adjust the
previously programmed duration for each program according to the specified budget entered for each month.
To enter Monthly Budget, press
. Press
to skip Uplink Budget and to move to the next feature.
The password screen provides the user a security against
unauthorized changes being made to the system. The Default
password is AAA. If the password has not been changed press
to continue. If the password has been changed, enter the
new password to continue. To enter the new password press
or
and underscore the digit to be
changed, then press
or
to select the appropriate letter. Repeat the steps for each letter. When
finished, press
or
to underscore OK. Press
to continue.
Budget information for the previous 12 months will appear with
January first and 100% as the default. Press the
or
to
underscore the percentage digits. Press
to increase or
to decrease the percentage (in increments of 10%). Press
or
to underscore OK. Press to
advance to the next month.
Repeat this procedure for the remaining months as needed. To skip a month, press.
Pass thru the 12
months to return to the Monthly Budget screen. Press
to continue.
NOTE:
To enable or disable an individual station to be budgeted see Setup System menu on page xx
5.4 CHECK STATUS
Review the Controller Status
This feature allows the user to review the current controller status
for the time, date, sensor activation, active program, if any valve is
open, manual run, rain stop progress and short or open circuit in valve
wiring. It also provides information on the controller’s availability for
communication (LEIT XRC only).
To enter Check Status press
. Press
to skip Check Status and move to the next feature.
15
Cancel Rain Stop?
l
Yes
No
MONTHLY
BUDGET?
Password: AAA
s
t
s
t
s
t
JAN 100%
Budget:
s
t
s
t
CHECK
STATUS?