Fuel Filter –Install FF-3003
on side of pump with draw
tube in the middle of the
filter nipple.
Water Separator Filter –Install FS-1001 on water
separator nipple without the draw tube. Make sure
to insert O-Ring provided on nipple.
Note: O-Ring must be put back on suction side of pump. Failure to do so can result in
priming issues, cavitation, or pressure loses.
Step 7:
Review Installation & Secure Connections