6.  OPERATING INSTRUCTIONS

IMPORTANT!

 Charge immediately after 

purchase and when battery level is below 

40%, to keep the internal battery fully 

charged and prolong battery life. Do not 

recharge unit for more than 12 hours.

POWERING ON

Press the ON/OFF power switch. The unit 

will initialize, and all icons on the LCD 

screen will activate. If normal function 

is detected, the screen will return to its 

normal display.

CHECKING THE LEVEL  

OF THE INTERNAL BATTERY

The Battery Capacity Indicator on the 

LCD display will show the battery’s charge 

level in 20-percent increments. For best 

performance, the battery capacity should 

be 20% or greater.

CHARGING THE INTERNAL BATTERY

NOTE:

 Do not use the unit while charging 

its internal battery.

AC adaptor

1. 

If the red AC Output LED is lit, press 

the AC Output button to turn off before 

charging. 

2. 

Connect the provided AC charger to 

the socket on the front of the unit. Plug 

the charger’s power cord directly into 

a live grounded 120V outlet. Charging 

will start automatically, and the   AC 

Adaptor Charging icon will show on 

the display.  

3. 

While the unit is charging, the rotating 

 Charging indicator will show on 

the display. When the internal battery 

is fully charged, all five bars of the  

Battery Capacity   indicator on the 

display will show. Complete charging 

will take approximately 5 hours. 

4. 

When the unit is fully charged, unplug 

the charger from the 120V outlet and 

then from the unit.

Solar Charging

Solar charging can be accomplished by 

plugging in a 30-36V solar panel (not 

included) into the Solar Charging Input port. 

The   Solar Charging icon will show on 

the display. For best results, face the panel 

toward the sun, away from curtains and 

windows. Charging by solar panel takes 

approximately 10 hours (on a sunny day).

POWERING A 12V DC DEVICE

NOTE:

 Do not power a 12V device while 

charging the internal battery. 

12V DC Output

1. 

Make sure the device to be powered is 

OFF before inserting the 12V DC plug 

into one of the two 12V DC output ports.

2. 

Plug the 12V DC device into one of the 

12V DC output ports and turn on the 

12V DC device (if required). The   

12V DC output icon and the rotating   

Discharging indicator will show on the 

display. 

3. 

When finished, turn off the DC device  

(if required) and unplug from the DC 

output port.

4. 

Recharge the unit when the battery 

level is below 40%.

12V DC Cigarette lighter plug

1. 

Make sure the device to be powered 

is OFF before inserting the 12V DC 

cigarette lighter plug into the 12V DC 

cigarette lighter socket.

2. 

Plug the 12V DC device into the DC 

cigarette lighter socket and turn on 

the 12V DC device (if required). The 

Cigarette Lighter Output icon and the 

rotating   Discharging indicator will 

show on the display.

3. 

When finished, turn off the DC device  

(if required) and unplug from the DC 

Cigarette Lighter socket.

4. 

Recharge the unit when the battery 

level is below 40%.

USING THE USB PORTS

The USB ports provide 1A, 2A and 2.4A  

at 5V DC.

1. 

Plug the device into one of the three 

USB ports on the front panel.

2. 

Turn on the USB device, if necessary. 

The   USB Output icon and the 

rotating   Discharging indicator will 

show on the display. 

3. 

When finished, turn off the USB 

device (if required) and unplug from 

the USB port.

4. 

Recharge the unit when the battery 

level is below 40%.

Summary of Contents for DH139

Page 1: ...NUAL DEL USUARIO Model Modelo DH139 CAUTION Read and follow all safety rules and operating instructions before every use of this product SAVE THESE INSTRUCTIONS ATENCIÓN Lea y siga todas las reglas de seguridad e instrucciones de uso antes de cada uso de este producto GUARDE ESTAS INSTRUCCIONES ...

Page 2: ... in the United States and Sears Brands LLC in other countries used under license GARANTÍA LIMITADA DIEHARD DURANTE UN AÑO desde la fecha de venta este producto está garantizado contra defectos de materiales o mano de obra cuando se opera de acuerdo a las instrucciones provistas CON EL COMPROBANTE DE VENTA devolver un producto defectuoso a la tienda donde fue comprado para el reemplazo gratuito Est...

Page 3: ...9 SPECIFICATIONS 9 REPLACEMENT PARTS 9 DISPOSAL INFORMATION 9 CONTENIDOS INSTRUCCIONES IMPORTANTES DE SEGURIDAD 10 PRECAUCIONES DE SEGURIDAD PERSONAL 10 INSTRUCCIONES DE MONTAJE 10 CARACTERÍSTICAS 11 PANTALLA LCD 11 INSTRUCCIONES DE OPERACIÓN 12 MANTENIMIENTO Y CUIDADO 14 ADVERTENCIAS 14 LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS 14 ANTES DE DEVOLVER A REPARACIONES 15 ESPECIFICACIONES 15 REPUESTOS 16 IN...

Page 4: ...To reduce risk of electric shock unplug the unit from the outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk 1 12 The unit gets uncomfortably warm during use and must have proper ventilation Ensure at least 3 in 7 5 cm air space is maintained on all sides of the unit 1 13 Do not set the unit on flammable materials such as carpeting upholstery paper ...

Page 5: ...output ports 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 10 12V DC cigarette lighter output only port 11 AC output button 12 AC output LED indicator 13 Handle 14 Light button 15 Light 16 Cooling vents 5 LCD SCREEN AC ADAPTOR CHARGING BATTERY CAPACITY INDICATOR SOLAR CHARGING WARNING POWER OUTPUT INDICATOR AC OUTPUT CHARGING INDICATOR USB OUTPUT 12V DC OUTPUT 12V DC CIGARETTE LIGHTER OUTPUT ...

Page 6: ...ded into the Solar Charging Input port The Solar Charging icon will show on the display For best results face the panel toward the sun away from curtains and windows Charging by solar panel takes approximately 10 hours on a sunny day POWERING A 12V DC DEVICE NOTE Do not power a 12V device while charging the internal battery 12V DC Output 1 Make sure the device to be powered is OFF before inserting...

Page 7: ...e an extension cord from the inverter to the device without significantly decreasing the power being generated by the inverter For best operating results the extension cord should be 16 AWG 1 31 mm2 or larger and no longer than 50 feet WARNING RISK OF ELECTRIC SHOCK Incorrect operation of your inverter may result in damage and personal injury The inverter output is 110V AC and can shock or electro...

Page 8: ...erload 9 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Power up failure Under voltage protection Abnormal load protection Damaged unit Recharge unit Remove loads and recharge unit Contact customer service Charger fault Unmatched charger Damaged charger Abnormal power supply or connection Use only the included charger Contact customer service for replacement Reconnect the charger If problem persists repla...

Page 9: ...thium Ion Capacity 750 Wh 25V 30 Ah AC input 147W 29 4V 5A Solar input 30 36V Max power up to 200W AC output 2 x 110V 60 Hz DC output 2 x 12V DC 2 5A Cigarette lighter output 1 x 12V DC 5A USB output 5V DC 1A 2A 2 4A Light 1W Operating Temperature 14 113 F 10 45 C Storage Temperature 32 113 F 0 45 C Dimensions H x W x D 13 7 x 6 3 x 11 2 349 mm x 6 3 mm x 285 mm Weight 16 7 lbs 7 6 kg 12 REPLACEME...

Page 10: ...escarga eléctrica desenchufe la unidad del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducirá este riesgo 1 12 La unidad se calienta considerablemente durante su uso y debe contar con ventilación adecuada Asegúrese de que se mantengan por lo menos 3 in 7 5 cm de espacio de aire en todos los lados de la unidad...

Page 11: ... 10 11 12 9 Puertos de salida de 12V de CC 10 Puerto de salida único de CC para encendedor de cigarrillos de 12V 11 Botón de salida de CA 12 Indicador LED de salida de CA 13 Manilla 14 Botón de luz 15 Luz 16 Ventilas de enfriamiento 5 PANTALLA LCD INDICADOR DE CAPACIDAD DE BATERÍA CARGADE ADAPTADOR DE CA CARGA SOLAR ADVERTENCIA INDICADOR DE POTENCIA DE SALIDA SALIDA DE CA INDICADOR DE CARGA SALIDA...

Page 12: ... de carga solar Para mejores resultados apunte el panel hacia el sol lejos de cortinas y ventanas La carga mediante panel solar toma aproximadamente 10 horas en un día soleado ALIMENTACIÓN DE UN DISPOSITIVO DE CC DE 12V NOTA No alimente un dispositivo de 12V mientras carga la batería interna Salida de CC de 12V 1 Asegúrese de que el dispositivo que va a energizar esté apagado antes de insertar el ...

Page 13: ... desde el inversor al dispositivo sin disminuir significativamente la potencia que genera el inversor Para los mejores resultados de operación el cable alargador debería ser de 16 AWG 1 31 mm2 o mayor y no tener más de 50 pies de largo ADVERTENCIA RIESGO DE CHOQUE ELÉCTRICO El funcionamiento incorrecto de su inversor podría causar daños y lesiones personales El voltaje de salida del inversor es de...

Page 14: ...dos N A Falla de salida de CC Cada 3 segundos N A Falla de salida de CA Cada 4 segundos N A Sobretemperatura 3 pitidos cortos cada 3 segundos N A Sobrecarga 9 LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS PROBLEMA CAUSA SOLUCIÓN Falla de encendido Protección contra subvoltaje Protección contra carga anómala Unidad dañada Recargue la unidad Retire las cargas y recargue la unidad Consulte al Servicio al Clie...

Page 15: ... PROBLEMA DE FUNCIONAMIENTO DESCONOCIDO por favor lea todo el manual y comuníquese con el número de atención al cliente para más información que no haga falta la devolución Si estas soluciones no eliminan el problema o si desea obtener más información sobre la solución de problemas o repuestos llame gratis al desde cualquier parte del U S A 1 800 621 5485 Lunes viernes 7 00am 5 00pm CST 11 ESPECIF...

Page 16: ...os Para evitar posibles daños al medio ambiente o a la salud humana por desechos no controlados y para promover la reutilización sostenible de recursos materiales recicle de manera responsable Para desechar un dispositivo usado use los sistemas de retorno y recolección o comuníquese con el distribuidor donde adquirió al producto para coordinar el reciclaje seguro 16 ...

Reviews: