CSS 110 OVERVIEW / 3
BUTTON FUNCTIONS
INCREASE
Increase the application rate.
DECREASE
Decrease the application rate.
MENU
Enter or exit the Menu if the master switch is OFF.
ON/OFF AND OK
A dual-purpose button to 1) turn on and off the device 2) accept a desired
setting/entry when in Menu mode.
MAIN SCREEN FUNCTIONS
Figure 3
Main Screen Functions
1. Graphic visualization of section nozzles
2. “F symbol indicates the FLUSH position is locked when pressing
MENU while the switch module is in FLUSH.
3. Effective working pressure (for pressure-based version)
4. Volume of product distributed. Press and hold the OK button for more
than 5 seconds to reset the value.
5. APER appears and an alarm engages if the valve reaches full open
while operating.
– Application rate set with switch in OFF position
– Effective application rate with switch in AUTO or FLUSH position
6. Ground speed
7. Area treated (example: 1 ha = 10.000 m
2
). Press and hold the OK
button for more than 5 seconds to reset the value.
NOTE: Press and hold the OK button for 5 seconds or more to
erase volume of product distributed and acreage treated values.
When a counter reaches the maximum value, an alarm activates and
these values must be erased.
F
1.20
l/m2
1.5
bar
kmh
l
ha
4.0
25
1.10
1