CONNECTION OF THE ELECTRIC CABLE TO THE ELECTRICITY
Instalation of electric feeder - This feeder must be separetely protectedby a safety fuse
according to the specific electric stream which depends on the wattage of the instaled device.
Check the wattage on the label atthe back of the device. Connect the device directly to the
electricity but you must put the switch between the device and electric net. The switch must
be placed in min. distance 3 mm between the particular contactsaccording to the standards and
loading. The feeder of grounding (yellow-green) cannot be interrupted by this switch. In every
case feeding cable must be placed so that no point of the cablewill reach the temperature
which is 50°C higher than the temperature of the surrounding. Before connecting the device
check that:
•
safety fuse of the feeder and inner mains can stand the loading of the device (see label
of the matrix)
•
mains are equipped with effective grounding according to standards (
Č
SN) and
conditions given by law
•
socket or switch of the feed is well accessible from device
We refuse any responsibility in case of not respecting above mentioned rules.
Before the first use
it is necessary to remove all the protection foil and to clean the device
- see chapter "cleaning and maintenance".
Maintenance:
We recommend to have the device checked once a year by the proffesional
service. Only qualified or competent persons can do interventions in the product.
INSTRUCTION FOR USE
Attention!
Before the first use of the device you must remove protection foil from all surfaces
and wash the device with water containing detergent and than splash with clean water.The
device is suitable for keeping the pommes frites in optimal temperature for serving. For better
effect we reccommend to add the infra lamp IL-1 to the keeper UH-12. This combination
secures you creation of the mikroclimat, which keeps the tasty quality of the pommes frits for
serving.
Control of the UH-12: Switch it on by the main switch (B) turn the control (C) from position
"0"to the desired position,it ranges 30°C - 90°C. Pilot lamps (C) and (D)will light. Pilot lamp
(C) lights when the devide is connected with electricity.Pilot lamp (D) lights when the heating
spirals are on. Pilot lamp (D) goes out when the device reaches required temperature. Switch
the device off by turning the knob (E) into position "0" and switch over the main switch (B).
You put the frits on the perforated plate which prevents the frits from absorbing the oil.
Control of the IL-1: Switch the lamp on by the switch (E). Operating indicates pilot lamp
(A).Lower performance and higher draining the heat off prevents overheating.
6