![Diamatic 3140 DBP Instruction Manual Download Page 8](http://html.mh-extra.com/html/diamatic/3140-dbp/3140-dbp_instruction-manual_2493175008.webp)
www.diamaticusa.com
The choice of professionals
US
6/12
Technical specifications
Parameter
Units
3140 DBP/LPP
Voltage / frequency
V/Hz
230/60
440/60**
230/60
440/60**
Power rating***
kW
6,85
6,85
5,15
Noise level
dB(A)
80
80
72
Peak noise*
dB(A)
81
81
75
Protection
IP
55
55
55
Insulation
Class
F
F
f
Container capacity
L
100
100
100
Inlet (diameter)
mm
70
70
70
Max vacuum
hPa - mbar
206 - 206
206 - 206
226-226
Maximum air flow rate (
with hose, length: 3 m, diameter: 76 mm)
m
3
/h - L/min’
550 - 9250
550 - 9250
462-7700
Main filter surface
m
2
15
15
15
Upstream absolute “H” filter surface - HEPA 14 according to
MPPS method (EN 1822)
m
2
3,5
3,5
3,5
* When the compressor is operating
** 400-480V/60 Hz
*** Suction unit + compressor
Parameter
Units
3140 DBP/LPP
Voltage / frequency
V/Hz
230/60
440/60**
230/60
440/60**
Power rating***
kW
6,85
6,85
5,15
Noise level @ 3’3” (1 meter)
dB(A)
80
80
72
Peak noise*
dB(A)
81
81
75
Protection
IP
55
55
55
Motor insulation
Class
F
F
F
Container capacity
Gallons/litres
26 - 100
26 - 100
26-100
Inlet (diameter)
Inches
3
3
3
Max vacuum
Inches H
2
O
8.21
8.21
9.06
Max air flow rate
cfm
327
327
272
Main filter surface
Sq. ft
162
162
162
Absolute filter surface (HEPA optional)
Sq. ft
38
38
38
Cable length
ft
30
30
30
HEPA filter efficiency
MPPS tested
99.995% @
0.18 micron
99.995% @
0.18 micron
99.995% @
0.18 micron
* When the compressor is operating
** 400-480V/60 Hz
*** Suction unit + compressor
Summary of Contents for 3140 DBP
Page 2: ......
Page 44: ...www diamaticusa com info diamaticusa com The choice of professionals 6 10 15 Q1 Q2 KM1 Q3 ...
Page 46: ...www diamaticusa com info diamaticusa com The choice of professionals 8 10 ...
Page 47: ...www diamaticusa com info diamaticusa com The choice of professionals 9 10 ...
Page 48: ...www diamaticusa com info diamaticusa com The choice of professionals 10 10 ...