8/12
Emergency stopping
Turn the main switch (
3) (figure 4) to “0” position.
Emptying the dust container
WARNING!
WARNING! To lift the container and empty it, when
using a forklift truck, use 4056000394 kit if the
total weight of the container and collected material
is not greater than 80 kg. For greater weights, use
Z5 36073 or Z5 36074 kit.
WARNING!
Before proceeding with these operations, turn off
the vacuum cleaner and remove the plug from the
power socket.
Figure 7
1.
Dust container
2.
Dust container release lever
Normal version
■
Release the dust container (
1
) using the lever (
2
), then
remove and empty it.
■
Make sure the seal is in perfect condition and correctly
positioned.
■
Place the container back in position and secure it again.
Operation of the filtering cartridges
Figure 9
1.
Electropneumatic device
2.
Filter cartridges
3.
Timer
The filtering cartridges (2) serve the purpose of filtering
the intake air. The vacuum cleaner is equipped with a fully
automatic electropneumatic device (
1
) to alternately clean
the filtering cartridges (2
), which guarantees continuous
service.
Powered with a 24V rating, is complete with cyclic timer (3
)
to regulate the following times:
T3
= time between one cleaning cycle and the next, set on 0
seconds;
T2
= time between one cleaning operation of the cartridge
(
2
) and the next, set on 20 seconds;
T1= opening time of the solenoid valve for backwashed
air exhaust into the cartridge, set at 2÷3 tenths of a
second. The shorter the time, the more energetic the
cleaning action will be.
Check the arrows on the knobs of the timer (3
) for the
exact regulation.
Factory setting should not be changed if without
consulting Diamatic.
The three solenoid valves of the electropneumatic device
control the cleaning of the relative filter cartridges.
Figure 16
1.
Filter cleaning solenoid valve E1
2.
Filter cleaning solenoid valve E2
3.
Filter cleaning solenoid valve E3
Tilting discharge device replacement
and use (3140 LPP)
Figure 8A
1.
Tilting discharge device assembly
■
Fasten the hopper to the filtering chamber, by inserting
it into the relevant housings and, operating on the lever
(
2) to lock it.
■
Insert the bag (Longopac
®
) into the relevant support
and fasten its end with the belt (
1
).
■
Engage the tilting discharge device support to the
hopper by fastening it with the relevant pins.
■
Remove the bag (Longopac
®
) until it lays on the lower
support platform and close its end with the supplied
clamp.
■
When the bag is full (Longopac
®
) close the upper end
with two clamps by fastening them at 50 mm one
from the other, then with a pair of scissors cut the bag
between the two clamps (
3
).
Single plastic bag replacement and
use
Figure 8B
Place the plastic bag outside the tilting discharge device
support, taking care that the bag bottom lays on the lower
support platform and lock the upper part of the bag with the
belt.
Summary of Contents for 3140 DBP
Page 2: ......
Page 44: ...www diamaticusa com info diamaticusa com The choice of professionals 6 10 15 Q1 Q2 KM1 Q3 ...
Page 46: ...www diamaticusa com info diamaticusa com The choice of professionals 8 10 ...
Page 47: ...www diamaticusa com info diamaticusa com The choice of professionals 9 10 ...
Page 48: ...www diamaticusa com info diamaticusa com The choice of professionals 10 10 ...