background image

• Make sure that the machine is connected to an appropriate power source 

in full working order (check the presence of a fully functional grounding 

socket) 

• Repairs must only be carried out by authorized personnel and only when 

the machine is turned off and disconnected from the power source 

• Never allow unauthorized personnel to use the machine

• Make sure that all safety devices are in full working order before turning 

on the machine 

• Never cover the vacuum cleaner during use 

7. INSTALLATION

7.1 DELIVERY AND HANDLING

All machines are carefully tested and checked by DiamaPro before 

delivery. The machine is transported inside a protective box or wrapped 

in a protective film that allows the courier to see the item during transport 

and is securely fixed to a pallet. If any part of the machine is not intact or 

has been damaged during transport, file an immediate complaint with the 

courier. Parts that have been damaged or broken due to incorrect transport 

or handling of the machine will not be recognized by the manufacturer’s 

warranty. The machine must be lifted and moved using a forklift truck in 

accordance with the relevant safety regulations in force in the workplace 

7.2 CHECK THE PROPER ELECTRICAL 

CONNECTION

Connect the industrial plug to the power cable and connect the plug to a 

socket that has the same amp rating and is protected by a line-isolating 

switch; in the case of the three-phase vacuum cleaner, it is necessary to 

check before use that the motor rotates in the correct direction (clockwise) 

as shown by the die-cast indicator on the turbine; if rotation occurs in an 

anti-clockwise direction, it is necessary to disconnect the machine from 

the power source, invert one of the three phase cables inside the plug and 

check again for correct rotation 

8. PERIODICAL MAINTENANCE

Maintenance and cleaning operations must ALWAYS be carried out when 

the vacuum is turned off and disconnected from the power source. No 

particular measures must be taken for the maintenance, cleaning or lubri-

cation of the suction unit. However, it is important to remember that correct 

use and servicing are essential if the safety and efficiency of the vacuum 

are to be guaranteed. 

To ensure regular and constant operation and to prevent the warranty from 

becoming void, always use genuine DiamaPro spare parts when repairs 

are needed. 

8.1 BEFORE TURNING ON AND TURNING OFF 

EVERY DAY

• Visually check that the suction hose has not been damaged in any way (it 

must not be damaged, torn, crushed) 

• Check that the electrical switches are in full working order and are not 

damaged in any way 

• Check the level of waste inside the main barrel N.B. Empty the main 

barrel if you are using an ATEX model empty the main barrel 

• Check that the suction hose has not been damaged in any way 

• Check that the motor head is correctly positioned on the filter chamber 

and that the latter is correctly placed on the main barrel 

• If the vacuum cleaner is moved, ensure that the power voltage of the play 

in this new location corresponds to the one on the technical data plate

8.2 AT EVERY 200 HOURS OF OPERATION

• Check the condition of the primary filter: it must not have tears, holes or 

other damage: in this case replace it (see 14.) 

• Check that the technical data plate is legible and not damaged in any 

way: contact the manufacturer for a replacement if necessary 

PERFORM THE FOLLOWING OPERATIONS AT 

EVERY 10 HOURS OF OPERATION IF THE VACUUM 

CLEANER IS AN ATEX MODEL 

9. PRODUCT DISPOSAL

Dispose of the machine and any accessories according to the legislation of 

the country. To avoid affecting the environment or your health or the health 

of others it is recommended to separate the machine from other waste, 

and if necessary properly recycle it. 

10. TECHNICAL DATA

MODEL

CODE

CERTIFICATE

MOTORS

VOLTAGE

FILTER CLEANING

PRIMARY FILTRATION CLASS

SECONDARY FILTRATION CLASS

USEFUL CAPACITY

CFM*

WATERLIFT

DIMENSIONS

INLET DIMENSION

TANK DIAMETER

WEIGHT

SOUND PRESSURE LEVEL (ISO 11201)

SVX2M

110V-60HZ

CE

2

110V-60 HZ

MANUAL

HEPA

HEPA D.O.P.

INFINITY BAGS

220

88 IN

48X29X54IN

2 IN

14.5 IN

108 LBS

<78

*Theoretical

Summary of Contents for SVX2-M

Page 1: ...OWNER S MANUAL SVX2 M INDUSTRIAL VACUUM USER MAINTENANCE BOOK SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ...

Page 2: ...ing essential details that are necessary when contacting the supplier manufacturer for advice suggestions or information on spare parts The following details are included on the plate Manufacturer Model Supply voltage Installed rated power CE symbol built in compliance with Machinery Directive 2006 42 EEC 4 2 TESTING All DiamaPro machines are tested before packaging and delivery in order to ensure...

Page 3: ...rticular measures must be taken for the maintenance cleaning or lubri cation of the suction unit However it is important to remember that correct use and servicing are essential if the safety and efficiency of the vacuum are to be guaranteed To ensure regular and constant operation and to prevent the warranty from becoming void always use genuine DiamaPro spare parts when repairs are needed 8 1 BE...

Page 4: ...xible hose to the desired accessory and the other with the quick coupling nozzle mounted on the filter chamber See the accessories sheet 13 USING THE VACUUM CLEANER Before switching ON the vacuum be sure the container is empty I 0 1 I 0 I Motor switch ON O Switch OFF 1 14 FILTER REPLACEMENT PRIMARY FILTER REPLACEMENT 1 Disconnect and lift the head A 2 Remove the filter B 3 Replace the filter with ...

Page 5: ... clean accessories Clean filter Dust comes out during the vacuuming u Filter has not been fastened correctly or is defective u Check to see if filter is sitting properly replace if required 1 Close the bag with two distanced bands 2 Cut the strip between the two bands 3 Pull the Infinity Bag end to make a new bag 17 COLLECTION BAG USE The dust and the particles are collected in a bag placed in the...

Page 6: ... the container and pull it slightly 6 Pull the outer part of the bag to create the new one 7 Insert the container with the Infinity Bag using the pins as reference 8 Bring the inside of the bag up to the height of the belt positioning Close the bag around the chamber with the belt 9 Pull the bag and place at the edge the band to create a new one If necessary use two bands 19 ELECTRIC DIAGRAM 1 TER...

Page 7: ...facturer declares that the technical file of the equipment is kept at This statement will expire automatically for 1 Changes to the equipment 2 Non compliance with instructions contained in the user and maintenance manual SVX2 M 2018 2006 42 CE CE Machinery Directive 2014 35 UE CE Low Voltage Directive 2014 30 UE CE EMC Directive EN ISO 12100 2010 EN 60335 2 69 EN 55014 1 2006 DiamaPro Systems P O...

Page 8: ...DiamaPro Systems P O Box 19946 Charlotte NC 28219 404 834 1162 Dealer s signature and stamp ...

Reviews: