Dialogic Vision TIGI2U Installing Download Page 7

Installing the Dialogic® Vision™ Server TIGI2U 

The following table summarizes the steps required for installing the Vision Server 
TIGI2U: 

Step 

Action 

Refer to... 

Install the Vision Server TIGI2U. 

Intel Server Deployment 
Toolkit
 CD 

Make a good low impedance connection to earth ground. This is 
required because DS-1 connections can be susceptible to 
lightning strike or power cross before a power source is provided 
for the device.  

Grounding the server on 
page 7 

Provide a power source for the server. 

Connecting to a power 
source
 on page 8 

Connect Ethernet interfaces to the device, if applicable. 

Connecting Ethernet 
cables
 on page 8 

Ensure that T1 connections are behind a channel service unit 
(CSU). 

Connecting to a T1 
network
 on page 9 

Connect device trunk interfaces, if applicable. 

Connecting T1/E1 trunk 
and SS7 signaling cables
 
on page 9 

 

After the installation is complete, configure the Vision Server TIGI2U as described in 
the documentation. Refer to the Accessing Vision Documentation document for 

information about accessing the documentation. 

Grounding the server 

Before connecting the server to a power source, be sure it is properly grounded. The 

server must be grounded using a two-hole #10x5/8 ground lug (Burndy 
YAV102TC10-90 or equivalent). Use four #10-32 nuts, one under and one on top of 

the ground lug as shown: 

 

 

Tighten each nut to 10 in-lbs torque. 
Note: The ground lug and nuts are not included with the server. 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for Vision TIGI2U

Page 1: ...Installing the Dialogic Vision Server TIGI2U April 22 2010 64 0404 02 www dialogic com Downloaded from Arrow com...

Page 2: ...roperty rights owned by third parties Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intell...

Page 3: ...AC power cords for AC servers Specified per order Intel Server Deployment Toolkit CD Intel Server universal rack mount kit Installing the Vision Server TIGI2U this document R TTE Declaration of Confo...

Page 4: ...nks 5 and 7 T1 E1 trunks 6 and 8 Ethernet 1 Ethernet 2 Ethernet 3 Ethernet 4 Line card Dialogic MD1 RJ 45 T1 E1 trunk interfaces Line card RJ 45 Ethernet interfaces Line card Optional line card T1 E1...

Page 5: ...cription Red LED on Yellow LED off Loss of frame loss of signal or bit error rate Yellow LED on Red LED off Remote loss of frame or remote loss of signaling multiframe Both LEDs on The line card is in...

Page 6: ...is a two person job If needed use an appropriate lifting device The following table provides the approximate weight for the Vision Server TIGI2U A Vision Server TIGI2U with Weighs approximately No li...

Page 7: ...Connecting to a T1 network on page 9 6 Connect device trunk interfaces if applicable Connecting T1 E1 trunk and SS7 signaling cables on page 9 After the installation is complete configure the Vision S...

Page 8: ...cting Ethernet cables To connect to a 10Base T 100Base T or 1000Base T network use two shielded twisted pair STP Category 5 or better Ethernet cables The two 10 100 1000Base T Ethernet connectors prov...

Page 9: ...g Vision Server TIGI2U The best way to provide a loopback is to unplug the cable from the Vision Server TIGI2U to the CSU The modular connector on most CSUs loops back the transmit signal to the recei...

Page 10: ...andards Each HSL occupies a full not channelized T1 E1 line and transfers data at the rate of 1 544 2 048 Mbps A single timeslot on a T1 E1 trunk carrying media The H 100 bus delivers the signaling li...

Page 11: ...rds Trunk connector 1 1 1 2 2 1 3 1 2 4 2 2 5 1 3 6 2 3 7 1 4 8 2 4 1 1 1 2 1 2 3 1 3 4 1 4 If two trunks connect to the physical connector a trunk adapter cable for example P N 32851 is required to s...

Page 12: ...table Service type Facility interface code Service order code USOC jack type 4 wire 1 544 Mbps DS1 with super frame SF alternate mark inversion AMI no line power 100 ohms 04DU9 BN 6 0N RJ 48C 4 wire 1...

Page 13: ...lephone lines and internal metallic water pipe system if present are connected together This precaution can be particularly important in rural areas Caution Users should not attempt to make such conne...

Page 14: ...t to change without notice For purchases not made directly from Dialogic please contact your direct vendor in connection with the warranty period and terms that they offer http www dialogic com warran...

Reviews: