Installing the Dialogic® Vision™ Server TIGI2U
7
The following table summarizes the steps required for installing the Vision Server
TIGI2U:
Step
Action
Refer to...
1
Install the Vision Server TIGI2U.
Intel Server Deployment
Toolkit CD
2
Make a good low impedance connection to earth ground. This is
required because DS-1 connections can be susceptible to
lightning strike or power cross before a power source is provided
for the device.
Grounding the server on
page 7
3
Provide a power source for the server.
Connecting to a power
source on page 8
4
Connect Ethernet interfaces to the device, if applicable.
Connecting Ethernet
cables on page 8
5
Ensure that T1 connections are behind a channel service unit
(CSU).
Connecting to a T1
network on page 9
6
Connect device trunk interfaces, if applicable.
Connecting T1/E1 trunk
and SS7 signaling cables
on page 9
After the installation is complete, configure the Vision Server TIGI2U as described in
the documentation. Refer to the Accessing Vision Documentation document for
information about accessing the documentation.
Grounding the server
Before connecting the server to a power source, be sure it is properly grounded. The
server must be grounded using a two-hole #10x5/8 ground lug (Burndy
YAV102TC10-90 or equivalent). Use four #10-32 nuts, one under and one on top of
the ground lug as shown:
Tighten each nut to 10 in-lbs torque.
Note: The ground lug and nuts are not included with the server.