Dialogic Vision TIGI2U Installing Download Page 5

Installing the Dialogic® Vision™ Server TIGI2U 

Ethernet LEDs 

The following illustration shows speed and activity LEDs on line card Ethernet RJ-45 

interfaces: 

 

Ethernet

Activity

Speed

 

Line card Ethernet interface speed and activity LEDs provide the following 
indications: 

LED 

Description 

Speed 

Data rate of the Ethernet link. 

Data rate 

LED 

10 Mb 

Off 

100 Mb 

On 

1000 Mb 

Blinking 

 

This LED is used only when a reliable Ethernet connection has been established and the 
activity LED is on. 

Activity 

There is activity on the line card Ethernet link. The LED flickers when the Ethernet 
establishes link integrity and when there is transmit or receive activity on the link. 

Trunk status LEDs 

The trunk status LEDs provide the following indications: 

LED status 

Description 

Red LED on 
Yellow LED off 

Loss of frame, loss of signal, or bit error rate. 

Yellow LED on 
Red LED off 

Remote loss of frame or remote loss of signaling multiframe. 

Both LEDs on 

The line card is in the process of establishing communication with the network. 

Both LEDs off 

Proper frame synchronization between the trunk and network has been established. 
All required framing alignment has been found (or the line card/trunk is not 
configured). 

SS7 signaling interface LEDs 

The SS7 signaling LEDs provide the following indications: 

Trunk LEDs 

Description 

Off 

Trunk is not configured. 

Slow blinking green 

Loss of signal. 

Fast blinking green 

Loss of frame or loss of signaling multiframe. 

Steady green 

Proper frame synchronization between the trunk and network is established 
and all required framing alignment has been found. 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for Vision TIGI2U

Page 1: ...Installing the Dialogic Vision Server TIGI2U April 22 2010 64 0404 02 www dialogic com Downloaded from Arrow com...

Page 2: ...roperty rights owned by third parties Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intell...

Page 3: ...AC power cords for AC servers Specified per order Intel Server Deployment Toolkit CD Intel Server universal rack mount kit Installing the Vision Server TIGI2U this document R TTE Declaration of Confo...

Page 4: ...nks 5 and 7 T1 E1 trunks 6 and 8 Ethernet 1 Ethernet 2 Ethernet 3 Ethernet 4 Line card Dialogic MD1 RJ 45 T1 E1 trunk interfaces Line card RJ 45 Ethernet interfaces Line card Optional line card T1 E1...

Page 5: ...cription Red LED on Yellow LED off Loss of frame loss of signal or bit error rate Yellow LED on Red LED off Remote loss of frame or remote loss of signaling multiframe Both LEDs on The line card is in...

Page 6: ...is a two person job If needed use an appropriate lifting device The following table provides the approximate weight for the Vision Server TIGI2U A Vision Server TIGI2U with Weighs approximately No li...

Page 7: ...Connecting to a T1 network on page 9 6 Connect device trunk interfaces if applicable Connecting T1 E1 trunk and SS7 signaling cables on page 9 After the installation is complete configure the Vision S...

Page 8: ...cting Ethernet cables To connect to a 10Base T 100Base T or 1000Base T network use two shielded twisted pair STP Category 5 or better Ethernet cables The two 10 100 1000Base T Ethernet connectors prov...

Page 9: ...g Vision Server TIGI2U The best way to provide a loopback is to unplug the cable from the Vision Server TIGI2U to the CSU The modular connector on most CSUs loops back the transmit signal to the recei...

Page 10: ...andards Each HSL occupies a full not channelized T1 E1 line and transfers data at the rate of 1 544 2 048 Mbps A single timeslot on a T1 E1 trunk carrying media The H 100 bus delivers the signaling li...

Page 11: ...rds Trunk connector 1 1 1 2 2 1 3 1 2 4 2 2 5 1 3 6 2 3 7 1 4 8 2 4 1 1 1 2 1 2 3 1 3 4 1 4 If two trunks connect to the physical connector a trunk adapter cable for example P N 32851 is required to s...

Page 12: ...table Service type Facility interface code Service order code USOC jack type 4 wire 1 544 Mbps DS1 with super frame SF alternate mark inversion AMI no line power 100 ohms 04DU9 BN 6 0N RJ 48C 4 wire 1...

Page 13: ...lephone lines and internal metallic water pipe system if present are connected together This precaution can be particularly important in rural areas Caution Users should not attempt to make such conne...

Page 14: ...t to change without notice For purchases not made directly from Dialogic please contact your direct vendor in connection with the warranty period and terms that they offer http www dialogic com warran...

Reviews: