Installing the Rack Mount Kit 

When mounting the server, follow these guidelines: 

 

Elevated operating ambient:

 If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack environment may be greater than 
room ambient. Therefore, consideration should be given to installing the equipment 
in an environment compatible with the maximum ambient temperature (Tma) 

specified by the manufacturer. 

 

Reduced air flow:

 Installation of the equipment in a rack should be such that the 

amount of air flow required for safe operation of the equipment is not compromised. 

 

Mechanical loading:

 Mounting of the equipment in the rack should be such that a 

hazardous condition is not achieved due to uneven mechanical loading. 

 

Circuit overloading:

 Consideration should be given to the connection of the 

equipment to the supply circuit and the effect that overloading of the circuits might 
have on overcurrent protection and supply wiring. Appropriate consideration of 

equipment nameplate ratings should be used when addressing this concern. 

 

Reliable earthing:

 Reliable earthing of rack-mounted equipment should be 

maintained. Particular attention should be given to supply connections other than 

direct connections to the branch circuit (for example, use of power strips). 

Before you install the server, you must install a rack mount kit to support the server in the 

rack. 
The Vision AQR1U Server comes with a tool-less rail mount system and a conversion kit so 
that the tool-less system can be used in a rack with either square holes or M5 round holes. 
The round hole conversion kit uses M5 screws for mounting the adapter to the rack. 
The rack mount kit is only used with a four-post rack and cannot be used with a two-post 
rack. Both kits may contain extra hardware.  

Kit 

Contents 

Tool-less rail kit 

 

Two slide rail assemblies 

 

Ten M4 x 6 screws 

 

Two M6 x 12 screws 

Round hole conversion 
kit 

 

Two slide rail assemblies 

 

Ten M4 x 6 screws (from the tool-less rail kit) 

 

Four hex standoff screws (from the tool-less rail kit) 

 

Four post adapter brackets 

 

With M5 x 8 screws 

 

Four 6-32 x 0.5" screws 

 

Two ear washers 

Summary of Contents for Vision AQR1U

Page 1: ...Installing the Dialogic Vision AQR1U Server September 15 2010 64 0605 01 Rev C www dialogic com...

Page 2: ...with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic More detailed information about such intellectual...

Page 3: ...unt Kit 14 Four Post Rack with Square Holes 15 Four Post Rack with Round Holes 15 Installing the Server 17 Mapping Ethernet Interfaces to MAC Address 19 MAC address mapping 20 Example 20 Cabling Compo...

Page 4: ...QR1U Server Regulatory Notices Note Save all packaging materials Your warranty requires that the server be returned in the original packaging If necessary additional packaging materials are available...

Page 5: ...18 One SS7 signaling interface VHW 011 019 One line interface 8 digital trunks and one SS7 signaling interface SS7 Configurations The SS7 link interface can be one of the following A single timeslot o...

Page 6: ...ht for the Vision AQR1U Server and the rack mount kit and screws does not include the weight for the shipping box and materials Vision AQR1U Server dimensions Caution Ventilation The equipment rack mu...

Page 7: ...xCPU Running Intel Maximum Power Application Typical 22 Degrees C 350 Watts 240 ports Video Gateway with video transcoding 2xCPU H264 to H263 Full Duplex Qcif 15 fps 42 kbit s 215 Watts 120 ports Vide...

Page 8: ...tion M Fault Minor fault Upper critical event indicating a warning For example the temperature of a component has reached a critical temperature reading P Fault Power supply fault If there is a fault...

Page 9: ...off when pressed again Can be illuminated remotely using a remote system identification command Power Power ON OFF Push and hold to turn the server on or off Note If a power failure occurs the server...

Page 10: ...ing interfaces Interface Description ETH4 ETH5 ETH9 ETH10 10 100 1000 Base T Ethernet interfaces ETH8 10 100 Base T Ethernet interface USB USB 2 0 interface The Vision AQR1U Server may include the fol...

Page 11: ...ring yellow or green Activity is present on the link Off No link Ethernet SPEED green Ethernet link data rate Steady green 100 Mbit s Off 10 Mbit s Blinking green 1 blink per second 1 Gb s Green LEDs...

Page 12: ...nk Off 10 Mbit s On 100 Mbit s Blinking 1000 Mbit s Trunk status Line interface trunk status Red Loss of frame loss of signal or bit error rate Yellow Remote loss of frame or remote loss of signaling...

Page 13: ...ched to the server before opening it Otherwise personal injury or equipment damage can result Maintenance There are no user serviceable parts inside the Vision AQR1U Server Only technically qualified...

Page 14: ...ropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable earthing Reliable earthing of rack mounted equipment should be maintained Particular attentio...

Page 15: ...kit to convert the square holes to round holes 1 Refer to the instructions included in the box with the Tool Less Blade Slide Kit to remove the inner channels from the slide kit and attach them to ea...

Page 16: ...0 kgf cm 3 9 4 3 lbf in 6 Slide the server with the attached inner channels into the slide rails and push the server all the way into the rack 7 Slide an ear washer onto the two 6 32 flat head screws...

Page 17: ...h the server and use them to secure the lug Tighten each screw to 10 lbs in torque Note The ground lug is not provided 2 Connect to a power source If you are installing an AC server connect a power co...

Page 18: ...by connecting the CSU to a functioning Vision AQR1U Server The best way to provide a loopback is to unplug the cable from the Vision AQR1U Server to the CSU The modular connector on most CSUs loops b...

Page 19: ...ons show the Ethernet interfaces on the Vision AQR1U Server Refer to these illustrations to identify the interface you are mapping the MAC address to Refer to the compliance label on the bottom of the...

Page 20: ...erface ETH3 motherboard interface MGT motherboard interface B0_ENET YY YY YY YY YY YY YY YY YY YY YY YY 1 ETH4 digital line interface ETH5 digital line interface B1_ENET ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ...

Page 21: ...MD1 RJ 21 to RJ 48C breakout modules The front of the panel contains the sixteen RJ 48C interfaces and the back of the panel contains two Dialogic MD1 RJ 21 interfaces Dialogic offers shielded cables...

Page 22: ...C connectors DC power cables A 500 mm DC power pigtail cable is included with servers that come with a DC power supply If you require a longer cable the 4 m cable is available for order P N 83369 Both...

Page 23: ...1363 10A 250VAC GB ACC000003 Continental Europe Pwr crd 2M IEC 320 C13 CEE 7 7 10A 250VAC FR ES DE ACC000004 Italy Pwr crd 2M IEC 320 C13 CEI 23 16 VII 10A 250VAC IT ACC000005 Switzerland Pwr crd 2M...

Page 24: ...s with multiple trunk connections should be distributed across multiple servers and line interface cards Video configurations support up to four trunks per card audio only configurations support up to...

Page 25: ...es The following illustration shows the two digital line interfaces on the Vision AQR1U Server connecting to the rear of a signal entry panel One SS7 Interface No Digital Line Interface The following...

Page 26: ...signments RJ 48C Interface The RJ 48C interface uses the following pin assignments Dialogic MD1 RJ 45 Interface The Dialogic MD1 RJ 45 interface uses the following pin assignments Pin Description Trun...

Page 27: ...e from network pin assignments 1 1 and 2 13 and 14 2 3 and 4 15 and 16 3 25 and 26 37 and 38 4 27 and 28 39 and 40 5 5 and 6 17 and 18 6 7 and 8 19 and 20 7 29 and 30 41 and 42 8 31 and 32 43 and 44 N...

Page 28: ...28 Detailed Dimensions The following illustrations provide detailed dimensions of the Vision AQR1U Server...

Page 29: ...ly 83364 3 AQR1U DC power pigtail 4 m long cable 83369 AQR1U 250 GB replacement disk drive 83370 AQR1U replacement fan assembly x4 83371 AQR1U replacement fan filters x10 83372 AQR1U rack mount kit 22...

Reviews: