Regulatory Approval 

4.1 

Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications.  However, there is no guarantee that 
interference will not occur in a particular installation.  If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one of the following measures: 
● 

Reorient or relocate the receiving antenna. 

● 

Increase the separation between the equipment and receiver. 

● 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

● 

Consult the dealer or an experienced radio/TV technician for help. 

4.1.1 

FCC Caution: 

Any changes or modifications not expressly approved by the party responsible for compliance could 
void the user's authority to operate this equipment. 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: 
(1) This device may not cause harmful interference, and 
(2) This device must accept any interference received, including interference that may cause 
undesired operation. 
  

4.1.2 

FCC Radiation Exposure Statement:  

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 
environment. This transmitter module must not be co-located or operating in conjunction with any 
other antenna or transmitter.  
The module must be installed in WiFi Module. 
This End equipment should be installed and operated with a minimum distance of 20cm between the 
radiator and your body. 
  
  

IMPORTANT NOTE:  

In the event that these conditions can not be met (for example certain laptop configurations or co-
location with another transmitter), then the FCC authorization is no longer considered valid and the 
FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be 
responsible for re-evaluating the end product (including the transmitter) and obtaining a separate 
FCC authorization.  
  

4.1.3 

End Product Labeling  

The final end product must be labelled in a visible area with the following:     
“Contains FCC ID: 2AU49-DA16200MC”, or “Contains FCC ID: 2AU49-DA16200ME” 
  

Summary of Contents for DA16200

Page 1: ...User Manual DA16200 AT GUI Tool...

Page 2: ...7 3 2 Board Connection 8 3 3 RF Certification Mode Setup 9 3 3 1 TX Test Mode 9 3 3 2 RX Test Mode 12 3 4 Network Mode Setup 12 3 4 1 Station Mode 13 3 4 2 AP Mode 14 3 5 OTP Mode Setup 16 4 Regulator...

Page 3: ...guration 9 Figure 10 Debug Console Tx mode 10 Figure 11 Start Stop Tx 11 Figure 12 Debug Console Start Tx 11 Figure 13 Debug Console Stop Tx 11 Figure 14 Rx Configuration 12 Figure 15 Network Mode Con...

Page 4: ...ous Receiver Transmitter SSID Service Set IDentifier DHCP Dynamic Host Configuration Protocol AP Access Point USB Universal Serial Bus MFC Microsoft Foundation Class References 1 DA16200 Datasheet Dia...

Page 5: ...The user just needs to connect with a micro USB cable and then two COM ports will be detected automatically If USB port is used install the FT232 Driver for windows In most cases it will be installed...

Page 6: ...uired to connect to the console of DA16200 Port Com port number on Windows system Baud rate 115 200 bps Data bits 8 bits Parity None Stop bits 1 bit Flow control None Figure 1 Terminal Configuration W...

Page 7: ...sing prompts when running this tool You need to install Microsoft Visual Studio redistributable package https www microsoft com en us download details aspx id 48145 or copy the dll file into the Windo...

Page 8: ...tected by the program press the R button to refresh COM Port Figure 4 RS232 Setup Disconnected Select a COM port and click the RS232 OPEN button Wait for a few seconds Connection status will be soon c...

Page 9: ...Certification Mode Setup To enable certification mode check on the mode option on the Chip Setting tab Figure 7 Certification Mode Configuration Alternatively on the Certification Mode tab Figure 8 C...

Page 10: ...er test and etc In this mode TX packet is generated continuously over 95 duty cycle CW mode Only single sinewave tone out mode This mode is for freq err check Data Rate Choose modulation type to test...

Page 11: ...tart TX Stop TX Figure 11 Start Stop Tx Tested setting is 802 11n MCS7 channel 1 100 bytes packet and power grade 0 When you click the Start TX button you can see messages as blow Figure 12 Debug Cons...

Page 12: ...st Mode RX Setting Channel Support CH1 CH13 Test Time Maximum 3600s Duration is 1 second fixed Figure 14 Rx Configuration RX Packet Rate FCS PHY Overflow packet Total packet Error rate 3 4 Network Mod...

Page 13: ...ck the Select button on the Mode Select option show in Figure 16 Network mode is changed DA16200 reboots and the station mode setup window will be shown as Figure 18 Figure 17 Debug Console Station Mo...

Page 14: ...20 Debug Console Connect to AP 3 4 2 AP Mode Choose the AP Mode and click the Select button on the Mode Select option then network mode is changed DA16200 reboots and the AP Mode setup window will be...

Page 15: ...0 2020 Dialog Semiconductor Figure 23 Debug Console AP Configuration Configure DHCP server Set IP addresses and click the Confirm button When a client is connected its MAC address will be shown as Fig...

Page 16: ...customer Freq Offset cal The range of frequency offset calibration is 0x0 0x7F MAC Address setup DA16200 provides 4 slots to store MAC addresses and the 1st slot is written by FCI The customer can us...

Page 17: ...CC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of th...

Page 18: ...device meets the exemption from the routine evaluation limits in section 2 5 of RSS102 and users can obtain Canadian information on RF exposure and compliance Le dispositif r pond l exemption des limi...

Page 19: ...DA16200 AT GUI Tool User Manual Revision 1 0 DRAFT 03 Jul 2019 CFR0012 19 of 20 2020 Dialog Semiconductor Revision History Revision Date Description 1 0 03 Jul 2019 Preliminary DRAFT Release...

Page 20: ...imitation the specification and the design of the related semiconductor products software and applications in accordance with its standard automotive change notification process Applications software...

Reviews: