DA16200 AT GUI Tool
User Manual
Revision 1.0 DRAFT
03-Jul-2019
CFR0012
16 of 20
© 2020 Dialog Semiconductor
3.5
OTP Mode Setup
To enable OTP mode, check on OTP Enable option on the OTP Mode tab then the current OTP data
will be shown in
Figure 26: OTP Mode
●
Power calibration
and
temperature calibration
has been completed for the chipset by FCI and
it may not need to be done by the customer.
●
Freq Offset cal
The range of frequency offset calibration is 0x0 ~ 0x7F.
●
MAC Address setup
DA16200 provides 4 slots to store MAC addresses and the 1st slot is written by FCI. The customer
can use 3 slots to write their own MAC address. The MAC address written in the OTP must be an
even number, it is used for WLAN0 MAC address (for STA interface), and the next number is
automatically used for WLAN1 MAC address (for Soft-AP interface).
To write the MAC address, give a MAC address in the first empty slot and click the Write button then
the new address substitutes for the previous address.