Document No.
9100-127-2044-99 Rev C
Release Date: August 2020
Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727
Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com
Page 16 of 21
Configuration Option Switches
NOTE:
In previous versions of the Dialight D1RW there were settings required for the
dip switches on the micro board.
This version only requires position 1 of SW1 to be used.
If being used as a Dual red and white beacon the micro board switches SW1 must be
set to the off position.
If being used as a White only system then SW1 position 1 should be set to the on
position.
NOTE:
The switches are factory set to the off position and positions 2, 3, & 4 should be
checked that they are set in the off position.
Micro / Filter Assembly Image
Capacitor Voltage Indication
Safety Warning
This unit holds a number of large capacitors for storage of the energy required
d
uring the Strobe’s flash duration. These capacitors may be charged with
voltages up to 185Vdc. Associated with each capacitor is a red indicator LED.
When lit, this indicates the capacitor voltage is 50V or higher. When power is
removed from the module the capacitors automatically discharge to 50V within 30
seconds.
Do not attempt any maintenance or wiring until the capacitors have been allowed
time to discharge to a safe level and all red indicator LED
’s have gone out.
SW1
Up is on towards
Black connectors
Down is off
Position 1
Position 4