DSP-10 User Manual
Page 5 of 26
DSP10_MAN_C
3. Technical Data
Functional Data
Sensitivity:
Ten sensitivities are user selectable.
Setting
Sensitivity
Setting
Sensitivity
0
.48% ΔL/L
5
.08% ΔL/L
1
.32% ΔL/L
6
.06% ΔL/L
2
.24% ΔL/L
7
.04% ΔL/L
3
.16% ΔL/L
8
.03% ΔL/L
4
.12% ΔL/L
9
.02% ΔL/L
Frequency Settings:
There are four frequency settings available. The actual loop frequency is
dependent on loop circuit inductance.
DIP Switch
Frequency
9
10
OFF
OFF
High
OFF
ON
Medium High
ON
OFF
Medium Low
ON
ON
Low
B Pulse Output:
250ms ±15ms.
Response Time:
Response time is dependent on the sensitivity selected.
Setting
Response Time
Setting
Response Time
0
70ms ±10ms
5
70ms ±10ms
1
70ms ±10ms
6
140ms ±20ms
2
70ms ±10ms
7
140ms ±20ms
3
70ms ±10ms
8
140ms ±20ms
4
70ms ±10ms
9
140ms ±20ms
Vehicle Hold Time:
In Normal Presence Mode: Approximately 1 hour for a detection of 1% ΔL/L.
In Extended Presence Mode: Approximately 19 hours for a detection of 1% ΔL/L.
Electrical Data
Loop Inductance:
20 microhenries to 1500 microhenries (including lead-in inductance). Not all
frequency settings are available at inductances below 30 microhenries.
Operating Voltages:
Three power versions:
10.5 volts to 30 volts AC or DC with over voltage protection
100 volts to 135 volts AC
200 volts to 270 volts AC
Output Relay Rating:
3 amps @ 125 volts