Handheld auxiliary controls with a spiral cable should only be used under the following conditions:
•
A fixed internal control should only be used inside the vehicle
body from a safe operator position that is a minimum 16"x16"
square, clearly and permanently marked at a minimum of 10"
from the hazard zone between the platform and the rear of the
vehicle floor (1 on figure directly right). A fixed internal control
should NEVER be used from a position on the platform.
•
The marked operator positions on the platform must be kept clear
at all times. It is prohibited to place a load on these dedicated
areas.
WARNING
•
When operating the liftgate, DO NOT stand in front or behind the load. Doing so puts the operator at risk of being pushed off the
platform or being crushed between the moving load and the rear frame of the vehicle body, resulting in serious bodily injury or
death.
•
To prevent this hazard, ALWAYS stand on the side of the load, NEVER in front or behind.
On the platform
, from a safe operator
position of
minimum 16”x16” square
,
clearly and permanently marked at
minimum
10”
distance from the hazard
zone between the platform and the rear
of the vehicle floor. Maintain 3 points of
contact (see page 17).
Inside the vehicle body
, from a safe
operator
position of minimum 16”x16”
square, clearly and permanently marked
at minimum
10”
distance from the hazard
zone between the platform and the rear
of the vehicle floor.
On the ground
, from a safe operator
position at a minimum of
20”
away from
the side edge of the platform.
20”
16”
10”
16”
10”
10”
16”
32”
❶